ASTM E2749-2015 Standard Practice for Measuring the Uniformity of Furnace Exposure on Test Specimens《测量试样的熔炉暴露均匀性的标准实践规程》.pdf
《ASTM E2749-2015 Standard Practice for Measuring the Uniformity of Furnace Exposure on Test Specimens《测量试样的熔炉暴露均匀性的标准实践规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2749-2015 Standard Practice for Measuring the Uniformity of Furnace Exposure on Test Specimens《测量试样的熔炉暴露均匀性的标准实践规程》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2749 10 (Reapproved 2014)E2749 15 An American National StandardStandard Practice forMeasuring the Uniformity of Furnace Exposure on TestSpecimens1This standard is issued under the fixed designation E2749; the number immediately following the designation indicates the year oforiginal ad
2、option or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This standard provides general principles for measuring the uniformity
3、 of the furnace exposure on specimens tested inaccordance with Test Methods E119, E814, E1529, E1725, E1966 and E2336.1.2 This practice specifies the materials and the construction requirements for a standardized test specimen used to provide amounting surface for the instrumentation that measures f
4、urnace exposure.1.3 The instrumentation records temperatures, pressure differentials and oxygen content near the surface of the test specimen.1.4 The values stated in SI units are to be regarded as the standard. The units given in parentheses are for information only.1.5 This standard is used to mea
5、sure and describe the response of materials, products, or assemblies to heat and flame undercontrolled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials,products, or assemblies under actual fire conditions.1.6 Fire testing is
6、 inherently hazardous. Adequate safeguards for personnel and property shall be employed in conducting thesetests.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate sa
7、fety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C1396/C1396M Specification for Gypsum BoardE119 Test Methods for Fire Tests of Building Construction and MaterialsE176 Terminology of Fire StandardsE814 Test Met
8、hod for Fire Tests of Penetration Firestop SystemsE1529 Test Methods for Determining Effects of Large Hydrocarbon Pool Fires on Structural Members and AssembliesE1725 Test Methods for Fire Tests of Fire-Resistive Barrier Systems for Electrical System ComponentsE1966 Test Method for Fire-Resistive Jo
9、int SystemsE2336 Test Methods for Fire Resistive Grease Duct Enclosure Systems2.2 ISO Technical Report:ISO/TR 834-2 Fire resistance tests Elements of building construction Part 2: Guide on measuring uniformity of furnaceexposure on test samples3. Terminology3.1 DefinitionsFor definitions of terms us
10、ed in this practice, refer to Terminology E176.3.2 Definitions of Terms Specific to This Standard:3.2.1 effective area of the furnace openingfurnace opening within the boundaries of the monitoring instrumentation.1 This practice is under the jurisdiction of ASTM Committee E05 on Fire Standards and i
11、s the direct responsibility of Subcommittee E05.11 on Fire Resistance.Current edition approved April 1, 2014Jan. 1, 2015. Published April 2014February 2015. Originally approved in 2010. Last previous edition approved in 2010 as E2749-10.DOI:10.1520/E2749-10R14.DOI:10.1520/E2749-15.2 For referencedAS
12、TM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user
13、of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as p
14、ublished by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14. Summary of Practice4.1 This practice consists of preparing a standardized test specimen to represent test specimens describe
15、d in Test Methods E119,E814, E1529, E1725, E1966 and E2336. The standardized test specimen provides a low cost, easily constructed supportingconstruction for the mounting of instrumentation that measures the exposure imposed by the furnace onto test specimens.4.2 The standardized test specimen consi
16、sts of two layers of 15.9 mm (58 in.) thick Type X gypsum board on the surface facingthe furnace chamber attached to steel channels and a single layer of structural panels (plywood or oriented strand board) attachedto the steel channels on the surface away from the furnace chamber. The gypsum board
17、provides a fire-resistive surface for themounting of the instrumentation. The structural panels provide stability for the steel support channels.4.3 Instrumentation to measure the thermal impact due to exposure to the furnace upon the standardized test specimen isinstalled at various locations on th
18、e exposed surface of the standardized test specimen. Probes used to gather air samples withinthe furnace chamber are also installed.4.4 The standardized test specimen is exposed to the time-temperature curve specified in referenced ASTM fire test standardsfor a time period of 45 min during which tim
19、e data are recorded by the instrumentation mounted on the standardized test specimen.4.5 The data provide a record of the conditions and uniformity of the furnace exposure upon standardized test specimens. Thearea bounded by the instrumentation installed on the standardized test specimen is designat
20、ed as the effective area of the furnaceopening.5. Significance and Use5.1 This practice describes a procedure to gather data intended to measure the uniformity of exposure conditions upon testspecimens for the fire test methods described in Test Methods E119, E814, E1529, E1725, E1966 and E2336. The
21、 collected datafrom furnaces are intended to form a basis for performance requirements for the furnaces described in the referenced standards.5.2 This practice does not include requirements for furnace performance.5.3 In this procedure, the standardized test specimen is subjected to one or more spec
22、ific sets of laboratory test conditions. Ifdifferent test conditions are substituted or the end-use conditions are changed, it is not always possible by or from this procedureto predict changes in the fire-test-response characteristics measured. Therefore, the results are valid only for the fire-tes
23、t-exposureconditions described in this procedure.5.4 The attention of all persons connected with the conduct of this practice is drawn to the fact that fire testing is hazardous andthat there is a possibility that harmful smoke and gases are developed during the test. There is also a possibility tha
24、t mechanicaland operational hazards develop during the construction of the test specimen and the disposal of the test residues. An assessmentof all potential hazards and risks to health shall be made and safety precautions shall be identified and provided. Written safetyinstructions shall be issued.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME27492015STANDARDPRACTICEFORMEASURINGTHEUNIFORMITYOFFURNACEEXPOSUREONTESTSPECIMENS 测量 试样 熔炉 暴露 均匀

链接地址:http://www.mydoc123.com/p-531817.html