ASTM E2738-2010 Standard Practice for Digital Imaging and Communication Nondestructive Evaluation (DICONDE) for Computed Radiography (CR) Test Methods《计算机射线照相(CR)试验方法用无损评估(DICONDE).pdf
《ASTM E2738-2010 Standard Practice for Digital Imaging and Communication Nondestructive Evaluation (DICONDE) for Computed Radiography (CR) Test Methods《计算机射线照相(CR)试验方法用无损评估(DICONDE).pdf》由会员分享,可在线阅读,更多相关《ASTM E2738-2010 Standard Practice for Digital Imaging and Communication Nondestructive Evaluation (DICONDE) for Computed Radiography (CR) Test Methods《计算机射线照相(CR)试验方法用无损评估(DICONDE).pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2738 10Standard Practice forDigital Imaging and Communication NondestructiveEvaluation (DICONDE) for Computed Radiography (CR) TestMethods1This standard is issued under the fixed designation E2738; the number immediately following the designation indicates the year oforiginal adoption
2、or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice facilitates the interoperability of computedradiography (CR) im
3、aging and data acquisition equipment byspecifying image data transfer and archival storage methods incommonly accepted terms. This practice is intended to be usedin conjunction with Practice E2339 on Digital Imaging andCommunication in Nondestructive Evaluation (DICONDE).Practice E2339 defines an in
4、dustrial adaptation of the NEMAStandards Publication titled Digital Imaging and Communica-tions in Medicine (DICOM, see http:/medical.nema.org), aninternational standard for image data acquisition, review,storage and archival storage. The goal of Practice E2339,commonly referred to as DICONDE, is to
5、 provide a standardthat facilitates the display and analysis of NDE results on anysystem conforming to the DICONDE standard. Toward thatend, Practice E2339 provides a data dictionary and a set ofinformation modules that are applicable to all NDE modalities.This practice supplements Practice E2339 by
6、 providing infor-mation object definitions, information modules and a datadictionary that are specific to computed radiography testmethods.1.2 This practice has been developed to overcome the issuesthat arise when analyzing or archiving data from CR testequipment using proprietary data transfer and
7、storage methods.As digital technologies evolve, data must remain decipherablethrough the use of open, industry-wide methods for datatransfer and archival storage. This practice defines a methodwhere all standard CR technique parameters and test results arecommunicated and stored in a standard manner
8、 regardless ofchanges in digital technology.1.3 This practice does not specify:1.3.1 A testing or validation procedure to assess an imple-mentations conformance to the standard.1.3.2 The implementation details of any features of thestandard on a device claiming conformance.1.3.3 The overall set of f
9、eatures and functions to be ex-pected from a system implemented by integrating a group ofdevices each claiming DICONDE conformance.1.4 Although this practice contains no values that requireunits, it does describe methods to store and communicate datathat do require units to be properly interpreted.
10、The SI unitsrequired by this practice are to be regarded as standard. Noother units of measurement are included in this practice.2. Referenced Documents2.1 ASTM Standards:E1316 Terminology for Nondestructive ExaminationsE1475 Guide for Data Fields for Computerized Transfer ofDigital Radiological Exa
11、mination DataE2339 Practice for Digital Imaging and Communication inNondestructive Evaluation (DICONDE)2.2 Other Documentation:National Electrical Manufacturers Association Standard forDigital Imaging and Communication in Medicine (DI-COM), 2008.3. Terminology3.1 Definitions:3.1.1 Nondestructive eva
12、luation terms used in this practicecan be found in Terminology E1316.3.1.2 DICONDE terms used in this practice are defined inPractice E2339.4. Summary of Practice4.1 A fundamental principle of DICONDE is the use ofstandard definitions and attribute formats for data communica-tion and storage. This m
13、eans all systems that are DICONDEcompliant use a common data dictionary and common com-munication protocols. To further standardization, the elementsin the data dictionary are organized into common groupsreferred to as information modules. The data dictionary andinformation modules common to all NDE
14、 modalities aredefined in Practice E2339.1This practice is under the jurisdiction of ASTM Committee E07 on Nonde-structive Testing and is the direct responsibility of Subcommittee E07.11 on DigitalImaging and Communication in Nondestructive Evaluation (DICONDE).Current edition approved Feb. 15, 2010
15、. Published March 2010. DOI: 10.1520/E2738-10.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.2 The data dictionary and information modules specifiedin Practice E2339 do not cover the information storagerequirements for each indivi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME27382010STANDARDPRACTICEFORDIGITALIMAGINGANDCOMMUNICATIONNONDESTRUCTIVEEVALUATIONDICONDEFORCOMPUTEDRADIOGRAPHYCRTESTMETHODS

链接地址:http://www.mydoc123.com/p-531792.html