ASTM E2709-2014e1 Standard Practice for Demonstrating Capability to Comply with an Acceptance Procedure《论证能力符合验收程序的标准实践规程》.pdf
《ASTM E2709-2014e1 Standard Practice for Demonstrating Capability to Comply with an Acceptance Procedure《论证能力符合验收程序的标准实践规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2709-2014e1 Standard Practice for Demonstrating Capability to Comply with an Acceptance Procedure《论证能力符合验收程序的标准实践规程》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2709 141An American National StandardStandard Practice forDemonstrating Capability to Comply with an AcceptanceProcedure1This standard is issued under the fixed designation E2709; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorial corrections made throughout in March 2015.1. Scope1.1 This practice provides a general metho
3、dology for evalu-ating single-stage or multiple-stage acceptance procedureswhich involve a quality characteristic measured on a numericalscale. This methodology computes, at a prescribed confidencelevel, a lower bound on the probability of passing an accep-tance procedure, using estimates of the par
4、ameters of thedistribution of test results from a sampled population.1.2 For a prescribed lower probability bound, the method-ology can also generate an acceptance limit table, whichdefines a set of test method outcomes (for example, sampleaverages and standard deviations) that would pass the accep-
5、tance procedure at a prescribed confidence level.1.3 This approach may be used for demonstrating compli-ance with in-process, validation, or lot-release specifications.1.4 The system of units for this practice is not specified.1.5 This standard does not purport to address all of thesafety concerns,
6、if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E456 Terminology Relating to Quality and Stat
7、isticsE2282 Guide for Defining the Test Result of a Test MethodE2586 Practice for Calculating and Using Basic Statistics3. Terminology3.1 DefinitionsSee Terminology E456 for a more exten-sive listing of terms in ASTM Committee E11 standards.3.1.1 characteristic, na property of items in a sample orpo
8、pulation which, when measured, counted or otherwiseobserved, helps to distinguish between the items. E22823.1.2 mean, nof a population, , average or expectedvalue of a characteristic in a population, of a sample X, sum ofthe observed values in a sample divided by the sample size.E25863.1.3 multiple-
9、stage acceptance procedure, na procedurethat involves more than one stage of sampling and testing agiven quality characteristic and one or more acceptance criteriaper stage.3.1.4 standard deviation, nof a population, , the squareroot of the average or expected value of the squared deviationof a vari
10、able from its mean of a sample, s, the square root ofthe sum of the squared deviations of the observed values in thesample divided by the sample size minus 1. E25863.1.5 test method, na definitive procedure that produces atest result. E22823.2 Definitions of Terms Specific to This Standard:3.2.1 acc
11、eptable parameter region, nthe set of values ofparameters characterizing the distribution of test results forwhich the probability of passing the acceptance procedure isgreater than a prescribed lower bound.3.2.2 acceptance region, nthe set of values of parameterestimates that will attain a prescrib
12、ed lower bound on theprobability of passing an acceptance procedure at a prescribedlevel of confidence.3.2.3 acceptance limit, nthe boundary of the acceptanceregion, for example, the maximum sample standard deviationtest results for a given sample mean.4. Significance and Use4.1 This practice consid
13、ers inspection procedures that mayinvolve multiple-stage sampling, where at each stage one candecide to accept or to continue sampling, and the decision toreject is deferred until the last stage.4.1.1 At each stage there are one or more acceptance criteriaon the test results; for example, limits on
14、each individual testresult, or limits on statistics based on the sample of test results,1This practice is under the jurisdiction of ASTM Committee E11 on Quality andStatistics and is the direct responsibility of Subcommittee E11.20 on Test MethodEvaluation and Quality Control.Current edition approve
15、d Oct. 1, 2014. Published October 2014. Originallyapproved in 2009. Last previous edition approved in 2012 as E2709 12. DOI:10.1520/E2709-14E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards v
16、olume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1such as the average, standard deviation, or coefficient ofvariation (relative standard deviation).4.2 T
17、he methodology in this practice defines an acceptanceregion for a set of test results from the sampled population suchthat, at a prescribed confidence level, the probability that asample from the population will pass the acceptance procedureis greater than or equal to a prespecified lower bound.4.2.
18、1 Having test results fall in the acceptance region is notequivalent to passing the acceptance procedure, but providesassurance that a sample would pass the acceptance procedurewith a specified probability.4.2.2 This information can be used for processdemonstration, validation of test methods, and q
19、ualification ofinstruments, processes, and materials.4.2.3 This information can be used for lot release(acceptance), but the lower bound may be conservative in somecases.4.2.4 If the results are to be applied to future test resultsfrom the same process, then it is assumed that the process isstable a
20、nd predictable. If this is not the case then there can beno guarantee that the probability estimates would be validpredictions of future process performance.4.3 This methodology was originally developed (1-4)3foruse in two specific quality characteristics of drug products inthe pharmaceutical indust
21、ry but will be applicable for accep-tance procedures in all industries.4.4 Mathematical derivations would be required that arespecific to the individual criteria of each test.5. Methodology5.1 The process for defining the acceptance limits, startingfrom the definition of the acceptance procedure, is
22、 outlined inthis section. A computer program is normally required toproduce the acceptable parameter region and the acceptancelimits.5.1.1 An expression for the exact probability of passing theacceptance procedure might be intractable when the procedureconsists of multiple stages with multiple crite
23、ria, hence a lowerbound for the probability may be used.5.2 Express the probability of passing the acceptance pro-cedure as a function of the parameters characterizing thedistribution of the quality characteristic for items in thesampled population.5.2.1 For each stage in the procedure having multip
24、leacceptance criteria, determine the lower bound on the prob-ability of that stage as a function of the probabilities of passingeach of the criteria in the stage:PSi! 5 PCi1and Ci2 and Cim! $1 2(j51m1 2 PCij! (1)where:P(Si) = is the probability of passing stage i,P(Cij) = is the probability of passi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME27092014E1STANDARDPRACTICEFORDEMONSTRATINGCAPABILITYTOCOMPLYWITHANACCEPTANCEPROCEDURE 论证 能力 符合 验收

链接地址:http://www.mydoc123.com/p-531741.html