ASTM E2692-2010(2018) Standard Test Method for Structural Performance of Thermal Barriers in Fenestration Products.pdf
《ASTM E2692-2010(2018) Standard Test Method for Structural Performance of Thermal Barriers in Fenestration Products.pdf》由会员分享,可在线阅读,更多相关《ASTM E2692-2010(2018) Standard Test Method for Structural Performance of Thermal Barriers in Fenestration Products.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2692 10 (Reapproved 2018)Standard Test Method forStructural Performance of Thermal Barriers in FenestrationProducts1This standard is issued under the fixed designation E2692; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revi
2、sion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method evaluates the longitudinal shearstrength before and after thermal cycling for therm
3、ally brokencomposite thermal barriers used in framing of windows, doors,and skylights. It also evaluates the ability of a thermal barrierto maintain its longitudinal dimension after thermal cycling.1.2 This test method is applicable to all fenestration prod-ucts that are constructed with structural
4、thermal barriers thatare affixed along their length to the adjoining metal profile1.3 This test method is meant to be applicable to many typesof fenestration frame types and is not meant to be specific toany single frame construction type.1.4 The values stated in SI units are to be regarded asstanda
5、rd. No other units of measurement are included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and dete
6、r-mine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendat
7、ions issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 AAMA Standards:2AAMA 505 Dry Shrinkage and Composite PerformanceThermal Cycling Test ProcedureAAMA TIR-A8 Performance of Composite Thermal BarrierFraming Systems3. Terminology3.1 Definit
8、ions:3.1.1 adhesive failure, nwhen an fenestration framingmember loses the bond with the thermal barrier, during theapplication of the load in the shear test.3.1.2 cohesive failure, nwhen the thermal barrier in afenestration framing member breaks apart within the matrix ofthe thermal barrier itself
9、during the application of the load inthe shear test.3.1.3 fenestration products, nwindows, doors, and sky-lights.3.1.4 longitudinal shear, nshear in a longitudinal plane, orparallel to the longitudinal axis, of the fenestration framingmember.3.1.5 metal failure, nyielding of the metal prior or equal
10、 to3 mm of displacement in the thermal barrier during theapplication of the load in the shear test.3.1.6 room temperature, nfor this test method, it shall bedefined as 22 6 3 C.3.1.7 thermal barrier or thermal break, nstructure con-necting inner and outer metal profiles of a fenestration framingmemb
11、er that consists of a thermally insulating (nonmetallic)material used for the purpose of reducing heat transfer acrossthe assembly.3.1.8 thermally broken composite, na fenestration framingmember composed of an inner and outer metal profile con-nected by a thermal barrier, affixed along their long ax
12、is.4. Summary of Test Method4.1 This test method subjects thermally broken fenestrationextrusions to shear load before and after thermal cycling.5. Significance and Use5.1 Thermal barriers require sufficient structural strength tocarry the loads imposed on fenestration members while reduc-ing the he
13、at transfer through the depth of the framing membersthroughout their service life.1This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.51on Performance of Windows, Doors, Skylights and Curtain Walls.Current
14、edition approved Sept. 1, 2018. Published September 2018. Originallyapproved in 2010. Last previous edition approved in 2010 as E269210. DOI:10.1520/E269210R18.2Available from the American Architectural Manufacturers Association(AAMA), 1827 Walden Office Square, Suite 550, Schaumberg, IL 60173-4268,
15、http:/www.aamanet.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for t
16、heDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.15.2 Sustained gravity, bending and tensile loads that stressthe thermal barrier (that is, glazing infill weight, wind loads,and glazing gasket pres
17、sure) are not covered by this testmethod.5.3 The reader is encouraged to read AAMA TIR-A8 forfurther information on thermal barriers and testing.6. Apparatus6.1 An environmental chamber shall be capable of main-taining a high temperature of 70 6 3 C and maintaining a lowtemperature of 29 6 3 C and t
18、he ability to ramp between thetwo temperatures at a controlled rate, within the time requiredon Fig. 1. The chamber shall have at least one thermocouple tomonitor the interior temperature of the chamber.6.2 A universal testing machine or similar equipment with aconstant rate of crosshead movement sh
19、all be capable ofexerting a measured force of up to 45 KN at a crosshead speedof 5 mm min.6.3 A test fixture shall be capable of holding one side of thefenestration framing member while exerting force on theopposite side of the fenestration framing member. (See Fig. 2.)FIG. 1 Thermal Cycling Schedul
20、e: One Cycle Air TemperaturesE2692 10 (2018)26.4 A measuring device capable of measuring 0.03 mmincrements.7. Hazards7.1 Take precautions when working near the testing ma-chine for specimens breaking under loading and creating flyinghazards. Take appropriate precautions when working aroundthe hot an
21、d cold materials.8. Test Specimens8.1 Test specimens shall be actual window extrusions froma manufactures production inventory. The test extrusionspretreatment, finish, and coating shall be identified and con-sistent with the manufacturers application technique andproduction inventory. In cases in w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME269220102018STANDARDTESTMETHODFORSTRUCTURALPERFORMANCEOFTHERMALBARRIERSINFENESTRATIONPRODUCTSPDF

链接地址:http://www.mydoc123.com/p-531710.html