《ASTM E2692-2010 Standard Test Method for Structural Performance of Thermal Barriers in Fenestration Products 《开窗产品中的热载体的结构性能的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2692-2010 Standard Test Method for Structural Performance of Thermal Barriers in Fenestration Products 《开窗产品中的热载体的结构性能的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2692 10Standard Test Method forStructural Performance of Thermal Barriers in FenestrationProducts1,2This standard is issued under the fixed designation E2692; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year o
2、f last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method evaluates the longitudinal shearstrength before and after thermal cycling for thermally brokencompo
3、site thermal barriers used in framing of windows, doors,and skylights. It also evaluates the ability of a thermal barrierto maintain its longitudinal dimension after thermal cycling.1.2 This test method is applicable to all fenestration prod-ucts that are constructed with structural thermal barriers
4、 thatare affixed along their length to the adjoining metal profile1.3 This test method is meant to be applicable to many typesof fenestration frame types and is not meant to be specific toany single frame construction type.1.4 The values stated in SI units are to be regarded asstandard. No other uni
5、ts of measurement are included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regu
6、latory limitations prior to use.2. Referenced Documents2.1 AAMA Standards:3AAMA 505 Dry Shrinkage and Composite PerformanceThermal Cycling Test ProcedureAAMA TIR-A8 Performance of Composite Thermal Bar-rier Framing Systems3. Terminology3.1 Definitions:3.1.1 adhesive failure, nwhen an fenestration fr
7、amingmember loses the bond with the thermal barrier, during theapplication of the load in the shear test.3.1.2 cohesive failure, nwhen the thermal barrier in afenestration framing member breaks apart within the matrix ofthe thermal barrier itself during the application of the load inthe shear test.3
8、.1.3 fenestration products, nwindows, doors, and sky-lights.3.1.4 longitudinal shear, nshear in a longitudinal plane,or parallel to the longitudinal axis, of the fenestration framingmember.3.1.5 metal failure, nyielding of the metal prior or equalto 3mm of displacement in the thermal barrier during
9、theapplication of the load in the shear test.3.1.6 room temperature, nfor this test method, it shall bedefined as 22 6 3C.3.1.7 thermal barrier or thermal break, nstructure con-necting inner and outer metal profiles of a fenestration framingmember that consists of a thermally insulating (nonmetallic
10、)material used for the purpose of reducing heat transfer acrossthe assembly.3.1.8 thermally broken composite, na fenestration fram-ing member composed of an inner and outer metal profileconnected by a thermal barrier, affixed along their long axis.4. Summary of Test Method4.1 This test method subjec
11、ts thermally broken fenestrationextrusions to shear load before and after thermal cycling.5. Significance and Use5.1 Thermal barriers require sufficient structural strength tocarry the loads imposed on fenestration members while reduc-ing the heat transfer through the depth of the framing membersthr
12、oughout their service life.5.2 Sustained gravity, bending and tensile loads that stressthe thermal barrier (that is, glazing infill weight, wind loads,and glazing gasket pressure) are not covered by this testmethod.5.3 The reader is encouraged to read AAMA TIR-A8 forfurther information on thermal ba
13、rriers and testing.1This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.51on Performance of Windows, Doors, Skylights and Curtain Walls.Current edition approved Jan. 15, 2010. Published March 2010. DOI: 10.1
14、520/E2692-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from the American Architectural Manuf
15、acturers Association(AAMA), 1827 Walden Office Square, Suite 550, Schaumberg, IL 60173-4268,http:/www.aamanet.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6. Apparatus6.1 An environmental chamber shall be capable of main-taini
16、ng a high temperature of 70 6 3C and maintaining a lowtemperature of 29 6 3C and the ability to ramp between thetwo temperatures at a controlled rate, within the time requiredon Fig. 1. The chamber shall have at least one thermocouple tomonitor the interior temperature of the chamber.6.2 A universal
17、 testing machine or similar equipment with aconstant rate of crosshead movement shall be capable ofexerting a measured force of up to 45 KN at a crosshead speedof 5 mm/min.6.3 A test fixture shall be capable of holding one side of thefenestration framing member while exerting force on theopposite si
18、de of the fenestration framing member. (See Fig. 2.)6.4 A measuring device capable of measuring 0.03 mmincrements.7. Hazards7.1 Take precautions when working near the testing ma-chine for specimens breaking under loading and creating flyinghazards. Take appropriate precautions when working aroundthe
19、 hot and cold materials.FIG. 1 Thermal Cycling Schedule: One Cycle Air TemperaturesE2692 1028. Test Specimens8.1 Test specimens shall be actual window extrusions froma manufactures production inventory. The test extrusionspretreatment, finish, and coating shall be identified and con-sistent with the
20、 manufacturers application technique andproduction inventory. In cases in which a complete windowwould use different profiles for sills, jamb, head, or interme-diates, a jamb extrusion may be considered representative ofthe other members provided the thermal barrier cavity pocketdesign, pretreatment
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME26922010STANDARDTESTMETHODFORSTRUCTURALPERFORMANCEOFTHERMALBARRIERSINFENESTRATIONPRODUCTS 开窗 产品

链接地址:http://www.mydoc123.com/p-531709.html