ASTM E2649-2009 Standard Test Method for Determining Argon Concentration in Sealed Insulating Glass Units Using Spark Emission Spectroscopy《气相色谱分析测定在密封绝缘玻璃元件中氩浓度的标准试验方法》.pdf
《ASTM E2649-2009 Standard Test Method for Determining Argon Concentration in Sealed Insulating Glass Units Using Spark Emission Spectroscopy《气相色谱分析测定在密封绝缘玻璃元件中氩浓度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2649-2009 Standard Test Method for Determining Argon Concentration in Sealed Insulating Glass Units Using Spark Emission Spectroscopy《气相色谱分析测定在密封绝缘玻璃元件中氩浓度的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2649 09Standard Test Method forDetermining Argon Concentration in Sealed Insulating GlassUnits Using Spark Emission Spectroscopy1This standard is issued under the fixed designation E 2649; the number immediately following the designation indicates the year oforiginal adoption or, in t
2、he case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers procedures for using a sparkemission spectroscope to determin
3、e the concentration of argongas in the space between the lites of a sealed insulating glassunit.1.2 This is a non-destructive test method.1.3 This test method shall be used only in a controlledlaboratory environment.1.4 This test method is applicable for insulating glass unitswith argon concentratio
4、ns of 70 % or more, where the balanceof the gas is atmospheric air.1.5 This test method is applicable for clear, double-glazedinsulating glass units.1.6 This test method is applicable for double-glazed insu-lating glass units with one lite having a metallic coating ortinted glass, or both, and with
5、clear glass as the other lite.1.7 This test method is applicable for triple-glazed insulat-ing glass units only when the center lite of glass has a metalliccoating (either low emissivity (low E) or reflective) and both ofthe other lites are clear glass.1.8 This test method also includes a procedure
6、for verifyingthe accuracy of the readings of the test apparatus.1.9 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.10 This stand
7、ard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificwarning statemen
8、ts, refer to 7.1.2. Referenced Documents2.1 ASTM Standards:2C 162 Terminology of Glass and Glass ProductsC 717 Terminology of Building Seals and SealantsE 631 Terminology of Building Constructions3. Terminology3.1 For definitions of terms found in this test method, referto Terminologies C 162, C 717
9、, and E 631.3.2 Definitions of Terms Specific to This Standard:3.2.1 sealed insulating glass unitan assembled unit, com-prising sealed lites of glass separated by dehydrated space(s),normally intended for clear vision areas of buildings.4. Summary of Test Method4.1 The spark emission spectroscope is
10、 placed against theglass surface of a sealed insulating glass unit in a prescribedmanner. A high voltage, at low current, is applied to the glasssurface. This voltage creates a spark which induces a plasmafrom the gas molecules inside the test specimen. This causeslight emissions (photons) of charac
11、teristic wavelengths. Theinstrument then collects the photons and analyzes them byspark emission spectroscopy. The resulting spectrum is com-pared to calibration data internal to the instrument to determinethe concentration of argon inside the unit.5. Significance and Use5.1 This test method is inte
12、nded to provide a means fordetermining the concentration of argon in sealed insulatingglass units under controlled conditions in compliance with theapparatus manufacturers instructions.1This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct resp
13、onsibility of Subcommittee E06.22on Durability Performance of Building Constructions.Current edition approved April 1, 2009. Published May 2009.2For referenced ASTM standards, visit the ASTM website, www.astm.org,orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards vo
14、lume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2 This is a non-destructive test method in that the edgeseal of the test specimen is not breached in
15、order to determinethe argon gas concentration. However, damage to some glasscoatings on the inner surfaces of the glass can occur.5.3 This test method has been developed based on datacollected in a controlled laboratory environment.5.4 The device shall be used to determine the argon gasconcentration
16、 in insulating glass units in a controlled labora-tory environment. Refer to 12.3.5.5 This test method may be used to determine the argon gasconcentration before, during, or after the insulating glass unit issubjected to durability tests.5.6 The accuracy of the test method is dependent upon theconce
17、ntration of argon gas.As the argon gas level decreases theaccuracy also decreases. When the concentration of argon isbelow 70 % this test method is not applicable.6. Apparatus6.1 Spark Emission Spectroscope:6.1.1 The apparatus employs a high voltage, at low current,source and employs spark emission
18、spectroscopy.6.1.2 The head of the spark emission spectroscope containsan electrode which is used to apply the voltage to the glasssurface of the test specimen. It also contains a light collectorwhich transmits light emissions to a spectrometer for process-ing.6.1.3 Different models3of the spark emi
19、ssion spectroscopeshall be acceptable provided that new models demonstrateaccuracy limits that are equal or greater to those of the originalmodel.6.2 Specimen Stand:6.2.1 The test specimen shall be supported in a verticalposition or up to 30 off vertical position.6.2.2 If necessary, a stand is used
20、to support the testspecimens. For example test stands, see Fig. 1 and Fig. 2.6.3 Background:6.3.1 A non-reflective black background shall be positionedbehind the test specimen. Examples of background materialsinclude photographic black fabric and black closed-cell foam.7. Hazards7.1 WarningThe high
21、voltage of the spark emissionspectroscope used in this test method can be harmful. Appro-priate protective measures shall be observed. Refer to theinstrument manufacturers instruction manual.8. Test Specimens8.1 Any sealed insulating glass unit that allows the sparkemission spectroscope to excite th
22、e gas present in the airspacecan be tested using this test method.8.2 Typically, test specimens are 355 mm 3 505 mm (14 in.3 20 in.) sealed insulating glass units constructed using onelite of 4 mm (532 in.) clear uncoated glass, a 12 mm (12 in.) airspace, and one lite of 4 mm (532 in.) coated low E
23、glass.Variations in the specimen construction may require a correc-tion. See the instrument manufacturers instruction manual forfurther information.9. Calibration9.1 Adjustment of the instrument is recommended to beperformed only by the manufacturer of the instrument or an3This method was based on u
24、se of the Gasglass 1002 device (the wand model).As of this writing, there are other models of the device which include V1 and V2(handheld models). The sole source of supply of these apparatuses known to thecommittee at this time is Sparklike, Ltd., Srkiniementie5C6,00210 Helsinki,Finland, http:/. If
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME26492009STANDARDTESTMETHODFORDETERMININGARGONCONCENTRATIONINSEALEDINSULATINGGLASSUNITSUSINGSPARKEMISSIONSPECTROSCOPY

链接地址:http://www.mydoc123.com/p-531616.html