ASTM E2598-2007 Standard Practice for Acoustic Emission Examination of Cast Iron Yankee and Steam Heated Paper Dryers《铸铁扬基和蒸汽加热纸烘干机的声发射检测用标准实施规程》.pdf
《ASTM E2598-2007 Standard Practice for Acoustic Emission Examination of Cast Iron Yankee and Steam Heated Paper Dryers《铸铁扬基和蒸汽加热纸烘干机的声发射检测用标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2598-2007 Standard Practice for Acoustic Emission Examination of Cast Iron Yankee and Steam Heated Paper Dryers《铸铁扬基和蒸汽加热纸烘干机的声发射检测用标准实施规程》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2598 07Standard Practice forAcoustic Emission Examination of Cast Iron Yankee andSteam Heated Paper Dryers1This standard is issued under the fixed designation E2598; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice provides guidelines for carrying out acous-tic emission (AE) examinations of Yankee and Steam
3、HeatedPaper Dryers (SHPD) of the type to make tissue, paper, andpaperboard products.1.2 This practice requires pressurization to levels usedduring normal operation. The pressurization medium may behigh temperature steam, air, or gas. The dryer is also subjectedto significant stresses during the heat
4、ing up and cooling downperiods of operation. Acoustic Emission data maybe collectedduring these time periods but this testing is beyond the scopeof this document.1.3 The AE measurements are used to detect, as well as,localize emission sources. Other methods of nondestructivetesting (NDT) may be used
5、 to further evaluate the significanceof acoustic emission sources.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the app
6、lica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A 278/A 278M Specification for Gray Iron Castings forPressure-Containing Parts for Temperatures Up to 650F(350C)E 543 Specification for Agencies Performing Nondestruc-tive TestingE 569 Practice for Acoustic
7、 Emission Monitoring of Struc-tures During Controlled StimulationE 650 Guide for Mounting Piezoelectric Acoustic EmissionSensorsE 976 Guide for Determining the Reproducibility ofAcous-tic Emission Sensor ResponseE 1316 Terminology for Nondestructive ExaminationsE 2374 Guide for Acoustic Emission Sys
8、tem PerformanceVerification2.2 ASNT Standards:3SNT-TC-1A Recommended Practice for NondestructiveTesting PersonnelANSI/ASNT CP-189 Standard for Qualification and Certi-fication of Nondestructive Testing Personnel3. Terminology3.1 DefinitionsSee Terminology E 1316 for general ter-minology applicable t
9、o this practice.4. Summary of Practice4.1 Each mounted sensor, on the cast iron vessel, monitorswhile the vessel is stationary and pressurized to normaloperating pressure. The vessel may be at ambient, or operating(250F-450F) temperature.4.2 Each mounted AE sensor is connected to an acousticemission
10、 signal processor. After a monitoring period (up to 10minutes) and pre-examination sensor sensitivity checks, pres-surization can begin.4.3 Location4.3.1 Zone LocationEach channel shall have the samesystem examination threshold. A simulated AE source gener-ated anywhere on the vessel shall be detect
11、ed by at least onesensor.4.3.2 Source LocationAll location data resulting fromanalysis shall be presented in a manner consistent with thepreviously established calibration accuracy. The simulated AEsource generated in each structure mounted sensor array shallbe detected by the minimum number of sens
12、ors required tolocate the source within 65 % of sensor spacing.4.4 Due to the potential for gasketed interfaces (at theheads/manway), multiple metal combinations (metalspray, caststeel-cast iron combinations), high vessel temperature, or1This practice is under the jurisdiction of ASTM Committee E07
13、on Nonde-structive Testing and is the direct responsibility of Subcommittee E07.04 onAcoustic Emission Method.Current edition approved Dec. 1, 2007. Published January 2008.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For An
14、nual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available fromAmerican Society for NondestructiveTesting (ASNT), P.O. Box28518, 1711 Arlingate Ln., Columbus, OH 43228-0518, http:/www.asnt.org.1Copyright ASTM International, 100 Barr Harb
15、or Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.random variations in the material velocity of cast iron, accuratesource location (65 % sensor spacing) may not always bepossible.4.5 Once the AE sensor source is localized, further evalua-tion is begun by observing a “history” of
16、 events involving thearea Head tilt (corrosion induced head strain), leak repair,objects through the nip (working contact with another roll),etc. This may give further direction to the selection of theNDE method to use for follow-up examination of the AEindication area.4.6 Secondary examination esta
17、blishes presence of flawsand measures flaw dimensions.4.7 Cast ironYankee dryers can be up to 22 feet in diameter,24 feet long, and weigh 100 tons, or more. Vessel thicknessmeasurements are available from the paper/tissue machineoperator. Cast iron is a brittle metal and has no specific yieldpoint.
18、Yankee dryers must maintain specific dimensional tol-erances. When a pressurized Yankee or steam heated paperdryer (SHPD) remains stationary, it fills with condensate at arapid rate. In an hour, a steam pressurizedYankee or SHPD canfill half way with condensate, doubling the weight on theframe, and
19、the floor. Some Yankee owners have corporaterequirements that a cast iron Yankee dryer remain stationaryfor12 hour, then rotation is required. Permission is required, ifthe Yankee is to remain stationary for more time. This issueshould be discussed with the responsible person prior to theexamination
20、.4.8 Yankee dryers operate under a heated hood. The hood isin close proximity to the Yankee shell and allows only inchesof clearance for the top half of the vessel.4.9 Cast iron steam heated paper machine dryers are 6 feetin diameter, or more, and may be 30 feet long.4.10 Gray cast iron experiences
21、a continuing reduction inelastic modulus as it is stressed to increasing higher levels. It isprudent not to stress grey cast iron material beyond itsoperating stress level.4.11 Flaws to be found are the same as those in any cast andmachined product. Attempts have been made to characterizestrength pr
22、operties of cast irons in compact tension tests. In aTAPPI sponsored laboratory study, two out of three cast ironcompact tension specimens experienced unplanned failures.From that experience it was cautioned that “cracks initiated andgrew faster than expected resulting in brittle fracture before the
23、process could be halted. The failure of these two couponsdemonstrated the rate in which cracks can grow in thesematerials and the materials inability to stop a crack once itbegins to grow. In each case, crack advance was extremelyrapid and without warning.44.12 Maximum Examination PressureMaximum Al
24、low-able Working Pressure for cast iron vessels is set based onASME (Section VIII) pressure calculations based on thickness,radius, and material strength values, and will not exceed 160psi and 450F (A278). When vessels are pressurized, anoma-lies produce emission at pressures less than normal fill p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME25982007STANDARDPRACTICEFORACOUSTICEMISSIONEXAMINATIONOFCASTIRONYANKEEANDSTEAMHEATEDPAPERDRYERS

链接地址:http://www.mydoc123.com/p-531512.html