《ASTM E2566-2008 Standard Test Method for Determining Visual Acuity and Field of View of On-Board Video Systems for Teleoperation of Robots for Urban Search and Rescue Applications《.pdf》由会员分享,可在线阅读,更多相关《ASTM E2566-2008 Standard Test Method for Determining Visual Acuity and Field of View of On-Board Video Systems for Teleoperation of Robots for Urban Search and Rescue Applications《.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2566 08Standard Test Method forDetermining Visual Acuity and Field of View of On-BoardVideo Systems for Teleoperation of Robots for UrbanSearch and Rescue Applications1This standard is issued under the fixed designation E 2566; the number immediately following the designation indicate
2、s the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of se
3、veral keyparameters of video systems for remote operations. It isinitially intended for applications of robots for Urban Searchand Rescue but is sufficiently general to be used for marine orother remote platforms. Those parameters are (1) field of viewof the camera system, (2) visual acuity at far d
4、istances withboth ambient lighting and lighting on-board the robot, (3)visual acuity at near distances, again in both light and darkenvironments, and (4), if available, visual acuity in both lightand dark environments with zoom lens capability.1.2 These tests measure only end-to-end capability, that
5、 is,they determine the resolution of the images on the displayscreen at the operator control unit since that is the importantissue for the user.1.3 This test method is intended to be used for writingprocurement specifications and for acceptance testing forrobots for urban search and rescue applicati
6、ons.1.4 This test method will use the Snellen fraction to reportvisual acuity; readers may wish to convert to decimal notationto improve intuitive understanding if they are more familiarwith that notation. Distances will be given in metres withEnglish units in parentheses following.1.5 This standard
7、 does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Terminology2.1 Definitions:2.
8、1.1 field of view, nangle subtended by the largest objectthat can be imaged with the video system.2.1.2 optotype, ncharacter used on a chart for testingvisual acuity.2.1.2.1 DiscussionOptotypes are generally built ona5by5 grid, with the size for “standard” vision subtending a square5 min of arc on a
9、 side. This makes one grid element 1 min ofarc square.2.1.3 tumbling E, nspecific optotype that can be drawn invarious orientations (facing left, right, up, or down) and invarious sizes to create an eye chart (see Fig. 1).2.1.3.1 DiscussionThis optoptype is reported in the litera-ture as being maxim
10、ally distinguishable. Eye charts withTumbling Es are available commercially for use at differentdistances.2.1.4 standard vision, nability to resolve target featuressubtending 1 min of arc.2.1.5 visual acuity, nability to resolve features subtendingsome angle, as compared with “standard” vision measu
11、red atthe same distance.2.1.5.1 DiscussionAn angle Q subtends a feature of size hat a distance d, of size 2h at a distance of 2d, of size 3h at adistance 3d, and so on. If 2d is the “standard” measurementdistance of 6 m (20 ft), an eye chart for use at 3 m (10 ft) wouldhave characters of h high rath
12、er than 2h high and themeasurement of visual acuity would be the same. See Fig. 2 foran illustration of the angle/distance relationship.2.1.6 Snellen fraction, na measure of visual acuity.2.1.6.1 DiscussionThe subject is placed a standard dis-tance from an eye chart, typically 6 m (20 ft). The subje
13、ct isasked to identify the line with the smallest characters that hecan resolve. The Snellen fraction is the ratio of the distance atwhich that line would be resolved by a subject with standardvision to the standard test distance. Thus, a subject withstandard vision would have 6/6 (20/20) vision.2.1
14、.7 remote operation, nact of controlling a distant roboton a continuous or intermittent basis via tethered or radio-linked devices while being provided with sensory information(for example, visual information through cameras onboard therobot).1This test method is under the jurisdiction of ASTM Commi
15、ttee E54 onHomeland Security Applications and is the direct responsibility of SubcommitteeE54.08 on Operational Equipment.Current edition approved Feb. 1, 2008. Published March 2008.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.2.1
16、.7.1 DiscussionRemote operation includes teleopera-tion as well as forms of intermittent autonomy or assistedautonomy.3. Units for Reporting Visual Acuity3.1 The commonly used distance for measuring visualacuity is 20 ft in the United States. This leads to the “Snellenfraction” as the common measure
17、 of visual acuity: 20/20,20/40, and so on. The Snellen fraction is also used in England,referred to 6 m as the standard measurement distance (6/6,6/12, etc.), while the rest of Europe generally used the decimalfraction equivalent: 20/20 = 6/6 = 1.0; 20/40 = 6/12=0.5, etc.Measurements may be taken at
18、 any distance and the resultscaled to the common distance.3.2 The meaning of 6/12 (20/40 or 0.5) is that features thatcan be resolved at 6 m (20 ft) by the test subject are of a sizesuch that a person with “standard” visual acuity could resolvethem at 12 m (40 ft). The characters on the 6/12 (20/40,
19、 0.5)line of an eye chart are twice the size of the characters on the6/6 (20/20, 1.0) line. The best human vision is not 6/6 (20/20,1.0), resolving 1 min of arc (1/60 = .016) but more like 6/3.6(20/12, 1.7), resolving about 0.01.4. Significance and Use4.1 Responder-defined requirements for these tes
20、t methodsare documented in a preliminary document entitled “Statementof Requirements for Urban Search and Rescue Robot Perfor-mance Standards.”24.2 Field of View is important in terms of the ability of theoperator to drive the robot. Looking at the world through azoom lens is like “looking through a
21、 soda straw.” Looking witha 30 or 40 field of view lens is like “driving with blinders on.”On the other hand, using a very wide field of view lens (witha field of view of 120 or 150), the operators use of optic flowto cue depth perception is severely degraded and navigating ina tight environment is
22、very difficult. Multiple cameras arerecommended, with one providing a very wide field of view orall together providing a very wide field of view.4.3 Far Vision Visual Acuity is important for both un-manned air vehicles (UAVs) and ground vehicles for wide areasurvey. Zoom is required for ground vehic
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME25662008STANDARDTESTMETHODFORDETERMININGVISUALACUITYANDFIELDOFVIEWOFONBOARDVIDEOSYSTEMSFORTELEOPERATIONOFROBOTSFORURBANSEARCHANDRESCUEAPPLICATIONSPDF

链接地址:http://www.mydoc123.com/p-531425.html