ASTM E2481-2006 Standard Test Method for Hot Spot Protection Testing of Photovoltaic Modules《光伏模块热冲击防护的标准试验方法》.pdf
《ASTM E2481-2006 Standard Test Method for Hot Spot Protection Testing of Photovoltaic Modules《光伏模块热冲击防护的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2481-2006 Standard Test Method for Hot Spot Protection Testing of Photovoltaic Modules《光伏模块热冲击防护的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2481 06Standard Test Method forHot Spot Protection Testing of Photovoltaic Modules1This standard is issued under the fixed designation E 2481; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision
2、. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method provides a procedure to determine theability of a photovoltaic (PV) module to endure the long-termeffects of peri
3、odic “hot spot” heating associated with commonfault conditions such as severely cracked or mismatched cells,single-point open circuit failures (for example, interconnectfailures), partial (or non-uniform) shadowing or soiling. Sucheffects typically include solder melting or deterioration of theencap
4、sulation, but in severe cases could progress to combus-tion of the PV module and surrounding materials.1.2 There are two ways that cells can cause a hot spotproblem; either by having a high resistance so that there is alarge resistance in the circuit, or by having a low resistancearea (shunt) such t
5、hat there is a high-current flow in a localizedregion. This test method selects cells of both types to bestressed.1.3 This test method does not establish pass or fail levels.The determination of acceptable or unacceptable results isbeyond the scope of this test method.1.4 This standard does not purp
6、ort to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 7
7、72 Terminology Relating to Solar Energy ConversionE 927 Specification for Solar Simulation for PhotovoltaicTestingE 1036 Test Methods for Electrical Performance of Non-concentrator Terrestrial Photovoltaic Modules and ArraysUsing Reference CellsE 1328 Terminology Relating to Photovoltaic Solar Energ
8、yConversionE 1799 Practice for Visual Inspections of PhotovoltaicModulesE 1802 Test Methods for Wet Insulation Integrity Testing ofPhotovoltaic Modules3. Terminology3.1 Definitionsdefinitions of terms used in this testmethod may be found in Terminology E 772 and TerminologyE 1328.3.2 Definitions of
9、Terms Specific to This Standard:3.2.1 hot spota condition that occurs, usually as a result ofshadowing, when a solar cell or group of cells is forced intoreverse bias and must dissipate power, which can result inabnormally high cell temperatures.4. Significance and Use4.1 The design of a photovoltai
10、c module or system intendedto provide safe conversion of the suns radiant energy intouseful electricity must take into consideration the possibility ofpartial shadowing of the module(s) during operation. This testmethod describes a procedure for verifying that the design andconstruction of the modul
11、e provides adequate protectionagainst the potential harmful effects of hot spots during normalinstallation and use.4.2 This test method describes a procedure for determiningthe ability of the module to provide protection from internaldefects which could cause loss of electrical insulation orcombusti
12、on hazards.4.3 Hot-spot heating occurs in a module when its operatingcurrent exceeds the reduced short-circuit current (Isc) of ashadowed or faulty cell or group of cells. When such acondition occurs, the affected cell or group of cells is forcedinto reverse bias and must dissipate power, which can
13、causeoverheating.NOTE 1The correct use of bypass diodes can prevent hot spot damagefrom occurring.4.4 Fig. 1 illustrates the hot-spot effect in a module of aseries string of cells, one of which, cell Y, is partiallyshadowed. The amount of electrical power dissipated in Y isequal to the product of th
14、e module current and the reversevoltage developed across Y. For any irradiance level, when thereverse voltage across Y is equal to the voltage generated by theremaining (s-1) cells in the module, power dissipation is at a1This test method is under the jurisdiction of ASTM Committee E44 on Solar,Geot
15、hermal and Other Alternative Energy and is the direct responsibility ofSubcommittee E44.09 on Photovoltaic Electric Power Conversion.Current edition approved March 1, 2006. Published March 2006.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at s
16、erviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.maximum when the module is short-circuited. This is
17、shown inFig. 1 by the shaded rectangle constructed at the intersection ofthe reverse I-V characteristic of Y with the image of theforward I-V characteristic of the (s-1) cells.4.5 By-pass diodes, if present, as shown in Fig. 2, beginconducting when a series-connected string in a module is inreverse
18、bias, thereby limiting the power dissipation in thereduced-output cell.NOTE 2If the module does not contain bypass diodes, check themanufacturers instructions to see if a maximum number of series modulesis recommended before installing bypass diodes. If the maximum numberof modules recommended is gr
19、eater than one, the hot spot test should bepreformed with that number of modules in series. For convenience, aconstant current power supply may be substituted for the additionalmodules to maintain the specified current.4.6 The reverse characteristics of solar cells can varyconsiderably. Cells can ha
20、ve either high shunt resistance wherethe reverse performance is voltage-limited or have low shuntresistance where the reverse performance is current-limited.Each of these types of cells can suffer hot spot problems, but indifferent ways.4.6.1 Low-Shunt Resistance Cells:4.6.1.1 The worst case shadowi
21、ng conditions occur whenthe whole cell (or a large fraction) is shadowed.4.6.1.2 Often low shunt resistance cells are this way becauseof localized shunts. In this case hot spot heating occurs becausea large amount of current flows in a small area. Because this isa localized phenomenon, there is a gr
22、eat deal of scatter inperformance of this type of cell. Cells with the lowest shuntresistance have a high likelihood of operating at excessivelyhigh temperatures when reverse biased.4.6.1.3 Because the heating is localized, hot spot failures oflow shunt resistance cells occur quickly.4.6.2 High Shun
23、t Resistance Cells:4.6.2.1 The worst case shadowing conditions occur when asmall fraction of the cell is shadowed.4.6.2.2 High shunt resistance cells limit the reverse currentflow of the circuit and therefore heat up. The cell with thehighest shunt resistance will have the highest power dissipa-tion
24、.4.6.2.3 Because the heating is uniform over the whole areaof the cell, it can take a long time for the cell to heat to thepoint of causing damage.4.6.2.4 High shunt resistance cells define the need forbypass diodes in the modules circuit, and their performancecharacteristics determine the number of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME24812006STANDARDTESTMETHODFORHOTSPOTPROTECTIONTESTINGOFPHOTOVOLTAICMODULES 模块 冲击 防护 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-531225.html