《ASTM E2480-2007 Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method with Multi-Valued Measurands《对带多值被测对象试验方法的精度测定进行的多实验室间研究用标准实施规.pdf》由会员分享,可在线阅读,更多相关《ASTM E2480-2007 Standard Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method with Multi-Valued Measurands《对带多值被测对象试验方法的精度测定进行的多实验室间研究用标准实施规.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2480 07Standard Practice forConducting an Interlaboratory Study to Determine thePrecision of a Test Method with Multi-Valued Measurands1This standard is issued under the fixed designation E 2480; the number immediately following the designation indicates the year oforiginal adoption o
2、r, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice describes the techniques for planning,conducting, and analyzing
3、 the results of an interlaboratorystudy (ILS) conducted for certain test methods within Com-mittee E12.1.2 This practice does not concern itself with the develop-ment of the test method but rather with the gathering of theinformation needed for the precision and bias statement afterthe completion of
4、 development of the test method. The dataobtained in the ILS may indicate, however, that further effort isneeded to improve the test method.1.3 This practice is concerned exclusively with test methodsthat derive a multi-valued measurand, such as, but not limitedto, spectral reflectance, transmittanc
5、e function, tristimulusvalues, or RGB values. Variation in measurements of suchmulti-valued measurands are usually analyzed by reducing thedata to a single-valued parameter, such as color difference, DE.1.4 This practice covers methods of dealing with the non-normal distribution of the variation of
6、sets of color-differences.This is done so that the user may derive valid statistics fromsuch non-normal distributions.1.5 This practice does not cover test methods, even inCommittee E12, whose measurands are single-valued, orwhose variations are known to be normally distributed. Taskgroups involved
7、with such test methods are referred to PracticeE 691 which contains preferable methods of analyzing datawith those properties.1.6 This practice is not intended to establish a method forestimating possible color-difference tolerances.1.7 The values stated in SI units are to be regarded as thestandard
8、. The values given in parentheses are for informationonly.1.8 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bil
9、ity of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE 284 Terminology of AppearanceE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE 1345 Pract
10、ice for Reducing the Effect of Variability ofColor Measurement by Use of Multiple Measurements3. Terminology3.1 DefinitionsFor color and appearance terms, see Ter-minology E 284.3.2 Definitions of Terms Specific to This Standard:3.2.1 precision and bias, nwhen a test method is appliedto a large numb
11、er of specimens that are as nearly alike aspossible, the test results obtained nevertheless will not all havethe same values. A measure of the degree of agreement amongthese test results describes the precision of the test method forthat material. This practice is designed only to estimate theprecis
12、ion of a test method. However, when accepted referencevalues are known for the materials being tested, the test resultdata obtained in accordance with this practice may be used toestimate the bias of the test method. For a discussion of biasestimation, see Practice E 177.3.2.2 repeatability and repr
13、oducibility, nthe term repeat-ability concerns the variability between independent test resultsobtained within a single laboratory in the shortest practicalperiod of time by a single operator applying the test methodwith a specific set of test apparatus using test specimens takenat random from a sin
14、gle quantity of homogeneous materialobtained, or prepared, for the ILS. The term reproducibilityconcerns the variability between single test results obtained indifferent laboratories, each by a different operator, each ofwhom has applied the test method to specimens taken atrandom from a single quan
15、tity of homogeneous materialobtained, or prepared, for the ILS.1This practice is under the jurisdiction of ASTM Committee E12 on Color andAppearance and is the direct responsibility of Subcommittee E12.93 on Precisionand Bias.Current edition approved July 1, 2007. Published August 2007.2For referenc
16、ed ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Co
17、nshohocken, PA 19428-2959, United States.3.2.2.1 DiscussionThe above single operator and singleapparatus requirement, as specified in 3.2.2, means that for aparticular step in the measurement process the same combina-tion of operator and apparatus is used to obtain every test resulton every specimen
18、. Thus, one operator could prepare andmount the specimen, another actuate the measurements, andstill another record the value of the result.3.2.2.2 DiscussionThe shortest practical period of timemeans that the test results are obtained in a time not less thannormal testing and not so long as to perm
19、it significant changesin material, equipment, calibration, or environment.3.2.2.3 DiscussionThe requirement that the measure-ments be independent means that a single test determinationbegins with the mounting of the specimen on the sample portor in the transmission compartment, and ends with the rem
20、ovalof the test specimen from the port or compartment. Allmeasurements are made with replacement.3.2.2.4 DiscussionThe requirement for different laborato-ries does not exclude the case where more than one instrumentresides in the same company, laboratory, or room, providedthat each has an independen
21、t and separate calibration traceabil-ity path from each other.3.2.3 test method and protocol, nin this practice, the termtest method applies to both the actual measurement process andthe written description of the process, while the term protocolrefers to the written instructions given the participa
22、nts forconducting the ILS.3.2.4 test specimens, nthe portion of the material beingtested needed for obtaining a single test determination is calleda test specimen. A single test specimen may be measured morethan once and the results combined to produce a test result ifthe protocol or test method so
23、specifies.4. Summary of Practice4.1 The procedure presented in this practice consists ofthree steps: planning the interlaboratory study, guiding thetesting phase of the study, and analyzing the test result data.The analysis includes the calculation of the numerical mea-sures of precision of the test
24、 method applying to both within-laboratory repeatability and between-laboratory reproducibil-ity.5. Significance and Use5.1 ASTM regulations require precision statements for alltest methods in terms of repeatability and reproducibility. Thispractice may be used in obtaining the information needed to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME24802007STANDARDPRACTICEFORCONDUCTINGANINTERLABORATORYSTUDYTODETERMINETHEPRECISIONOFATESTMETHODWITHMULTIVALUEDMEASURANDS

链接地址:http://www.mydoc123.com/p-531222.html