《ASTM E2459-2005 Standard Guide for Measurement of In-Duct Sound Pressure Levels from Large Industrial Gas Turbines and Fans《测量大型工业燃气轮机和风扇的管内声压级的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2459-2005 Standard Guide for Measurement of In-Duct Sound Pressure Levels from Large Industrial Gas Turbines and Fans《测量大型工业燃气轮机和风扇的管内声压级的标准指南》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2459 05Standard Guide forMeasurement of In-Duct Sound Pressure Levels from LargeIndustrial Gas Turbines and Fans1This standard is issued under the fixed designation E 2459; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revis
2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide is intended to provide a simple and consistentprocedure for the in-situ field measurement
3、 of in-duct soundpressure levels in large low pressure industrial air ducts, suchas for gas turbines or fans, where considerations such as flowvelocity, turbulence or temperature prevent the insertion ofsound pressure sensors directly into the flow. This standardguide is intended for both ambient te
4、mperature intake air andhot exhaust gas flow in ducts having cross sections of four (4)square meters, or more.1.2 The described procedure is intended to provide a repeat-able and reproducible measure of the in-duct dynamic pressurelevel at the inlet or exhaust of the gas turbine, or fan. The guideis
5、 not intended to quantify the “true” sound pressure level orsound power level. Silencers, as well as Waste Heat Boilers,must be designed using the in-duct sound power level as thebasis. Developing the true sound power level based on in-ductmeasurements of true sound pressure within a complete oper-a
6、ting system is complex and procedures are developmental andoften proprietary.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determ
7、ine the applica-bility of regulatory limitations prior to use. Extreme caution ismandatory when working near hot exhaust gas systems andappropriate safety precautions such as the installation of quickacting isolation valves are recommended.2. Referenced Documents2.1 ASTM Standards:2C 634 Terminology
8、 Relating to Environmental Acoustics2.2 ANSI Standards:S1.4 Specification for Sound Level Meters3S1.43 Specification for Integrating Averaging Sound LevelMeters33. Terminology3.1 Definitions of the acoustical terms used in this guide aregiven in Terminology C 634.3.2 Definitions of Terms Specific to
9、 This Standard:3.2.1 anechoic tubea constant diameter tube of sufficientlength that a sound wave reflected from the far end of the tubetermination arrives at the microphone position sufficientlyattenuated that it will not appreciably affect the microphonereading.3.2.2 dynamic pressurethe total insta
10、ntaneous pressureincident upon the opening of the test port, including theinfluence of convective turbulence, local tangential modes,localized boundary layer effects at the test port and theindeterminate effects of all duct acoustical modes.3.2.3 fixturethe apparatus containing the microphone fit-ti
11、ng which locates the microphone flush with the insidediameter of the anechoic tube, the necessary fittings permittingairtight connection of the fixture and anechoic tube to the testport, and the anechoic tube.3.2.4 probe microphonea commercially available micro-diameter microphone probe that is inse
12、rted into the anechoictermination near the test port connection. Some probes requirea pressure compensation connection. Use and installation shallfollow manufacturers procedures/instructions.3.2.5 test portthe hole in the duct wall to which theanechoic tube is connected and whose diameter is equal t
13、o theinside diameter of the anechoic tube. In general the term testport, as used herein, will usually include any semi-permanentlyinstalled hardware in the wall of the duct permitting closure ofthe test port when not in use (ball valve and threaded pipe cap,or both) as well as the pipe elements perm
14、itting attachment ofthe fixture and the anechoic tube.1This guide is under the jurisdiction ofASTM Committee E33 on EnvironmentalAcoustics and is the direct responsibility of Subcommittee E33.08 on Mechanicaland Electrical System Noise.Current edition approved Oct. 15, 2005. Published November 2005.
15、2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI),
16、 25 W. 43rd St.,4th Floor, New York, NY 10036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4. Summary of Guide4.1 Key features of this guide:4.1.1 Athrough-wall test port opening, 25.4 mm (nominally,1 in.) or less, to which is con
17、nected the fixture, having aconstant inside diameter tube, to which the anechoic tube isconnected.The test port opening is flush with the inside surfaceof the duct wall. No apparatus are inserted into the flow path.4.1.2 The microphone sensor is mounted in the fixture(3.2.3) outboard of the duct wal
18、l, with the microphone axisoriented normal to the centerline of the anechoic tube.4.1.3 The tip of the microphone, usually with a protectivegrid, is positioned flush with, or more accurately tangential to,the inner wall of the fixture and as close to the duct wall astemperature or access limitations
19、 permit.4.1.4 The diameter of the microphone shall always be lessthan or equal to the inside diameter of the anechoic tube.4.1.5 The position of the microphone is critical for hightemperature ducts, so as to limit the maximum temperature onthe microphone during testing.4.1.6 The anechoic tube shall
20、have no inner wall disconti-nuities or changes in diameter that might create reflections orstanding waves within the tube. It is important to avoid anyprotrusion of the apparatus into the gas flow path.4.1.7 The anechoic termination may be achieved by looselypacking the “cold” end of the tube with m
21、ineral wool or steelwool. The tube end should be sealed airtight unless forced airis to be used to ensure adequate cooling of the anechoic tube.4.1.8 The inner duct wall opening shall be as smooth aspracticable, with a minimum of turbulence producing discon-tinuities at the duct wall inner surface.
22、If the user chooses tomount a protective screen covering the inside duct wallopening, such screen shall not materially influence the soundpressure measurements, or a means of quantifying and ac-counting for such influence shall be included in the testprotocol. (Be aware that such screens can become
23、fouled withparticles.)4.1.9 The inner duct wall opening shall be the same insidediameter as the inside diameter of the anechoic tube. That is,this guide does not permit the anechoic tube to be inserted into,or positioned within a duct wall port of larger size, unlessmeans are provided to ensure that
24、 the inner wall surface at thetest port is restored to a reasonable semblance of a smoothcontinuous wall surface.4.2 A sketch of a typical Test Port is shown in Fig. 1.Asketch of a typical Fixture is shown in Fig. 2. Only the initialportion of the otherwise very long Anechoic Tube is depictedin each
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME24592005STANDARDGUIDEFORMEASUREMENTOFINDUCTSOUNDPRESSURELEVELSFROMLARGEINDUSTRIALGASTURBINESANDFANS

链接地址:http://www.mydoc123.com/p-531170.html