《ASTM E2458-2017 Standard Practices for Bulk Sample Collection and Swab Sample Collection of Visible Powders Suspected of Being Biological Agents and Toxins from Nonporous Surfaces《.pdf》由会员分享,可在线阅读,更多相关《ASTM E2458-2017 Standard Practices for Bulk Sample Collection and Swab Sample Collection of Visible Powders Suspected of Being Biological Agents and Toxins from Nonporous Surfaces《.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2458 10E2458 17Standard Practices forBulk Sample Collection and Swab Sample Collection ofVisible Powders Suspected of Being BiothreatBiologicalAgents and Toxins from Nonporous Surfaces1This standard is issued under the fixed designation E2458; the number immediately following the desig
2、nation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These practices address collect
3、ion of visible powders that are suspected biothreatbiological agents and toxins from solidnonporous surfaces using a bulk collection method, using a dry swab and laminated card, followed by a swab sampling methodusing a sterile moistened swab. Bulk powder samples are collected and packaged in a mann
4、er that permits the maximum amountof the sample to be safely transported to a reference laboratory within the Centers for Disease Control and Prevention (CDC)national Laboratory Response Network (LRN)2 for confirmatory identification and safe storage. If the source of the powder is aletter or small
5、package, that item is also packaged in a manner that permits it to be safely transported to an LRN referencelaboratory. A sterile moistened swab may be used to collect residual powder from the nonporous surface and may be used toconduct on-site biological assessments for the purpose of testing for b
6、iothreat agents.biological agents and toxins.1.2 These practices are performed in coordination with the Federal Bureau of Investigation (FBI) as part of a risk assessmentincluding hazard assessment and threat credibility evaluation as recommended and clarified in Guide E2770. The decision toimplemen
7、t these practices and collect a public safety sample will be made by members of the response community of thejurisdiction assuming responsibility through coordination with the FBI and the receiving LRN reference laboratory.1.3 Sample Collection Method A covers the bulk collection and packaging of su
8、spicious visible powders that are suspectedbiothreatbiological agents and toxins from solid nonporous surfaces. All samples suspected to be biothreatbiological agents andtoxins on nonporous surfaces should be collected according to Sample Collection Method A and sent to aan LRN referencelaboratory f
9、or confirmatory testing.1.4 Sample Collection Method B covers swab sampling of residual suspicious powders that are suspected biothreatbiologicalagents and toxins from solid nonporous surfaces. Swab samples can be used for on-site biological assessment; however resultsfrom on-site biological assessm
10、ents are not definitive; confirmatory testing by the LRN reference laboratory is necessary to makepublic health decisions.1.5 These practices incorporate reference guidance for packaging and transport of suspicious visible powders to comply withall appropriate federal regulations regarding biosafety
11、 and biosecurity.1.6 These practices should only be used to collect visible samples that are suspected biothreatbiological agents and toxins andhave been field screened according to reference guidance for explosive hazard, radiological hazard, and other acute chemicalhazards.1.7 The values stated in
12、 SI units are to be regarded as standard. The values given in parentheses are for information only.1.8 This standard does not purport to address all of the safety concerns associated with its use. It is the responsibility of theuser of this standard to establish appropriate safety and health practic
13、es and determine the applicability of regulatory limitationsprior to use.1.9 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recom
14、mendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.1 These practices are under the jurisdiction of ASTM Committee E54 on Homeland Security Applications and are the direct responsibility of Subcommittee E54.01 onCBRNE Sensors and Detectors.Current edition app
15、roved Oct. 1, 2010May 15, 2017. Published November 2010June 2017. Originally approved in 2006. Last previous edition approved in 20062010 asE2458 06.E2458 10. DOI: 10.1520/E2458-10.10.1520/E2458-17.2 The CDC Laboratory Response Network is the network responsible for handling clinical specimens and e
16、nvironmental samples containing suspected biothreat agents.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all chang
17、es accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. Uni
18、ted States12. Referenced Documents2.1 ASTM Standards:3E2770 Guide for Operational Guidelines for Initial Response to Suspected Biological Agents and ToxinsF2412 Test Methods for Foot ProtectionF2413 Specification for Performance Requirements for Protective (Safety) Toe Cap Footwear2.2 Federal Govern
19、ment Regulations:418 USC 175178 Prohibitions with respect to biological weaponsDOT 49 CFR, Parts 171-180 Hazardous Materials RegulationsDOT - 49 CFR 172 Subpart H, Transportation TrainingDOT - 49 CFR 173 General Requirements for Shipments and PackagingsDOT - 49 CFR 178 Specifications for PackagingsE
20、PA - 40 CFR 300 National Oil and Hazardous Substances Pollution Contingency Plan (NCP)EPA - 40 CFR 311 Worker ProtectionNRC - 10 CFR 20 Standards for Protection against RadiationNIOSH - 42 CFR 84 Respiratory Protective DevicesOSHA - 29 CFR 1910 Subpart Z and 29 CFR 1926 Subpart Z Toxic and Hazardous
21、 SubstancesOSHA - 29 1910.1096 and 29 CFR 1926.53 Ionizing RadiationOSHA - 29 CFR 1910.120 Hazardous Waste Operations and Emergency Response (HAZWOPER) standardOSHA - 29 CFR 1910 Subpart I (Sections 132 to 139) Personal Protective EquipmentOSHA - 29 CFR 1910.1200 Hazard Communication2.3 Federal Guid
22、ance:OSHA - CPL 02-02-073 Inspection Procedures for 29 CFR 1910.120 and 1926.65, Paragraph (q): Emergency Response toHazardous Substance ReleasesNIOSH Publication No. 2009-132 Recommendations for the Selection and Use of Respirators and Protective Clothing forProtection Against Biological AgentsFBI
23、Laboratory Publication Handbook of Forensic Services 20032013FBI-DHS-HHS/CDC Coordinated Document Guidance on Initial Response to a Suspicious Letter/Container with a PotentialBiological threat, November 2, 2004CDC/NIOSH Surface Sampling Procedures for Bacillus anthracis Spores from Smooth, Non-poro
24、us Surfaces, April 26, 20125DHS Framework for a Biothreat Field Response Mission Capability, April 20116Sandia National Laboratories SAND2005-3237 (LBNL-54973 (II) Guidelines to Improve Airport Preparedness AgainstChemical and Biological Terrorism72.4 NFPA Standards:8NFPA 472 Standard for Competence
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME24582017STANDARDPRACTICESFORBULKSAMPLECOLLECTIONANDSWABSAMPLECOLLECTIONOFVISIBLEPOWDERSSUSPECTEDOFBEINGBIOLOGICALAGENTSANDTOXINSFROMNONPOROUSSURFACESPDF

链接地址:http://www.mydoc123.com/p-531169.html