ASTM E2358-2004 Standard Specification for the Performance of Glass in Permanent Glass Railing Systems Guards and Balustrades《固定玻璃围栏系统、护栏和栏杆的性能的标准规范》.pdf
《ASTM E2358-2004 Standard Specification for the Performance of Glass in Permanent Glass Railing Systems Guards and Balustrades《固定玻璃围栏系统、护栏和栏杆的性能的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2358-2004 Standard Specification for the Performance of Glass in Permanent Glass Railing Systems Guards and Balustrades《固定玻璃围栏系统、护栏和栏杆的性能的标准规范》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2358 04Standard Specification forthe Performance of Glass in Permanent Glass RailingSystems, Guards, and Balustrades1This standard is issued under the fixed designation E 2358; the number immediately following the designation indicates the year oforiginal adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers glass in permanent railingsystems, guards and balustrades installed in
3、 agricultural, as-sembly, commercial, educational, industrial, institutional, rec-reational, and residential buildings.1.2 This specification is intended to be applied to permanentglass railing systems for buildings and to such railing systems,rails, guards and balustrades having major structural co
4、mpo-nents made of glass, or the secondary components such as infillor balusters made of glass.1.3 This specification considers that the overall outlook isbased on the health and safety of all potential users ofbuildings. The criteria incorporated in this specification pro-vide for normal and anticip
5、ated building uses, but not forabuses for which the building and its components are notdesigned.1.4 This specification establishes basic minimum require-ments and criteria that lead to satisfactory products undernormal use conditions and does not give consideration todesign criteria for specific fie
6、ld conditions, the establishment ofwhich is the prerogative and responsibility of the designer,specification writer, and regulatory agencies.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard
7、to establish appro-priate safety and health practices and to determine theapplicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 631 Terminologies of Building ConstructionsE 2025 Test Method for Evaluating Fenestration Compo-nents and Assemblies for Resista
8、nce to Impact EnergiesF 1233 Test Method for Security Glazing Materials andSystemsE 935 Test Method for Performance of Permanent MetalRailing Systems and Rails for BuildingsE 1481 Terminology of Railing Systems and Rails forBuildingsE 2353 Test Methods for Performance of Glass in Perma-nent Glass Ra
9、iling Systems, Guards, and Balustrades2.2 Other Standards:ANSI Z97.1 Glazing Materials Used in Buildings, SafetyPerformance Specifications and Methods of Test3CPSC 16 CFR Part 1201 Architectural Glazing Materials,Federal Register43. Terminology3.1 Definitions: General terms used in this standard tes
10、tmethod are defined in Terminologies E 631 and E 1481. Termscommon to this standard test method and referenced testmethods are defined in the respective document unless definedherein.3.2 Definitions of Terms Specific to This Standard:3.2.1 Failure LoadA load, which, if placed upon a struc-ture or te
11、st piece, is just great enough to break it.3.2.2 Glazing Retentionthe property of maintaining theglass or glazing material, post breakage, in a system, such thatthe glass must be held in the framing system with no openingsufficient to pass a 76 mm (3 in.) solid steel sphere through thesystem using a
12、 horizontally applied force of 18 N (4.0 lbs).3.2.3 Guard SystemA protective railing system along theouter edges of locations of an accessible roof, parapet, balcony,landing, platform or ramp, designed to minimize the probabil-ity of an accidental fall from the walking surface.3.2.4 Interlayera laye
13、r of material acting as an adhesivebetween lites of glazing, which adds additional performanceattributes to the finished product, for example: impact resis-tance, solar control, and acoustical insulation.3.2.5 Litea term for a single pane (or piece) of glass orother glazing material.3.2.6 Stileone o
14、f the upright structural members of aframe or a framework of bars1This specification is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.56on Performance of Railing Systems and Rails for Buildings.Current edition approved No
15、v. 1, 2004. Published November 2004.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American
16、National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.4Available from U.S. Consumer Product Safety Commission (CPSC), 4330East-West Hwy., Bethesda, MD 20814.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
17、4. Design Requirements4.1 Railing Height4.1.1 Guardrail Systems:4.1.1.1 The fabricated height of a guardrail system, mea-sured from its top surface to the finished floor level, shall be atleast 1070 mm (42 in.). When variation in the evenness of thefinished floor will result in any individual height
18、 measurementof the installed guardrail system to be less than 1040 mm (41in.), the fabricated height of the entire guardrail system shall beincreased accordingly.4.1.1.2 Within an individual dwelling unit, the requiredrailing height shall be permitted to be reduced as allowed bythe governing jurisdi
19、ction.4.1.1.2.1 Where the vertical distance between adjacent fin-ished floor levels is less than 1830 mm (72 in.), the height ofthe guardrail system shall be at least 810 mm (32 in) (Fig. 1).When variation in the evenness of the finished floor results inany individual height measurement of the insta
20、lled guardrailsystem less than 790 mm (31 in), the fabricated height of theentire guardrail system shall be increased accordingly.4.1.1.2.2 Where the vertical distance between adjacent fin-ished floor levels is a minimum of 1830 mm (72 in.), the heightshall be a minimum of 860 mm (34 in.) (Fig. 2).
21、Whenvariations in the evenness of the finished floor results inindividual height measurements of the installed guardrailsystem less than 840 mm (33 in.), the fabricated height of theguardrail system shall be increased accordingly.4.1.1.3 In public assembly, elementary school, and multiple-family bui
22、ldings where the vertical distance between stair andadjacent floor levels is more than 6100 mm (20 ft), the requiredheight of the top of the railing above the finished floorincluding any variation shall be at least 1220 mm (48 in.).4.1.1.4 For balconies in public-assembly buildings, therequired rail
23、ing height in front of the first row of fixed seatsshall be reduced to 660 mm (26 in.) provided adequate safetyis established by the design and approved by the authorityhaving jurisdiction; however, it shall be a minimum of 910 mm(36 in.) at aisle ends and a minimum of 1070 mm (42 in.)where aisle st
24、eps are perpendicular to the railing system.4.1.2 Handrails and Stair-rail Systems4.1.2.1 In corridors, ramp, walkways, and enclosed stair-ways having a slope of at least 1 in 20, the height of thehandrail of the stair-rail system, measured from its top surfaceto the finished floor level or tread-no
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME23582004STANDARDSPECIFICATIONFORTHEPERFORMANCEOFGLASSINPERMANENTGLASSRAILINGSYSTEMSGUARDSANDBALUSTRADES

链接地址:http://www.mydoc123.com/p-530964.html