《ASTM E2316-2003(2009) Standard Test Method for Determination of Particles Resulting from the Attrition of Granular Pesticides《测定粒状农药磨损产生微粒的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2316-2003(2009) Standard Test Method for Determination of Particles Resulting from the Attrition of Granular Pesticides《测定粒状农药磨损产生微粒的试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 2316 03 (Reapproved 2009)Standard Test Method forDetermination of Particles Resulting from the Attrition ofGranular Pesticides1This standard is issued under the fixed designation E 2316; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is used to determine the amount andparticle size distribution curve of
3、 particles with diameter 106micrometers or smaller resulting from the attrition of granularpesticides.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, i
4、f any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatement, see Section 8.2. Referenced Documents2.1 ASTM Standards:2E
5、11 Specification for Wire Cloth and Sieves for TestingPurposesE 725 Test Method for Sampling Granular Carriers andGranular Pesticides2.2 CIPAC Standard:CIPAC Test Method MT 18733. Terminology3.1 Definitions:3.1.1 finesa synonym for particles with diameter of 106micrometers or smaller.3.1.2 micron an
6、d msynonyms for micrometer.4. Summary of Test Method4.1 The initial weight of a test sample of granular pesticideis determined. The sample is then air jet sieved using 106micron openings to remove the inherent fines. The fines-freegranules are then combined with glass beads in a glass jar, thelid is
7、 placed on the jar, and the jar is placed on a roller systemwith a drive bed capable of rotating the jar at a known rpm.After rolling for a specified time period, the jar is removedfrom the rollers and the contents of the jar are poured througha sieve sized to remove the glass beads. The sample minu
8、s theglass beads is again air jet sieved using 106micron openings toremove the fines attrited during the rolling of the jar. The totalof particles smaller than 106microns for the test sample is theinherent fines plus the attrited fines. The particle size distribu-tion curve of the combined inherent
9、and attrited fines isdetermined by laser light diffraction using CIPAC Test MethodMT 187.5. Significance and Use5.1 This test method is designed specifically for granularpesticide formulations.5.2 This test method helps provide information on healthhazards likely to arise from exposures by the inhal
10、ation route.It can be of use in selecting dose levels for chronic studies andfor establishing safety criteria for human exposure.5.3 The amount of fines determined by this method is ameasure of potential inhalation and respiration toxicity becausethe hazards of inhaled solid substances are influence
11、d byphysical factors such as particle size.6. Apparatus6.1 Roller System, two or more rollers with a drive bed,capable of rotating the specified glass jar at 75 6 15 rpm.1This test method is under the jurisdiction of ASTM Committee E35 onPesticides and Alternative Control Agents and is the direct re
12、sponsibility ofSubcommittee E35.22 on Pesticide Formulations and Delivery Systems.Current edition approved March 1, 2009. Published March 2009. Originallyapproved in 2003. Last previous edition approved in 2003 as E 2316 031.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcon
13、tact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The size distribution of the particles with sieve diameter less than 106m isdetermined by laser light diffraction using CIPAC Test Meth
14、od MT 187.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.2 Glass Jar, with lid, capacity 500 mL, outer diameter8 cm, height 15 cm.6.3 Glass Beads, diameter 4.0 6 0.2 mm, bulk density 1.5g/cc.6.4 Micron Air Jet Sieve, with GAZ 125
15、cyclone finescollector or Alpine Air Jet Sieve, with GAZ 125 cyclone finescollector,4or equivalent.6.5 Sieves, U.S. standard series conforming to SpecificationE11, diameter 8 in. (203 mm), height 2 in. (51 mm): 10-mesh(2 mm openings), 140-mesh (106m openings).NOTE 1The amount of particles with sieve
16、 diameter 106m orsmaller is determined by sieving.6.6 Balance, sensitivity of 0.01 g.6.7 Hygrometer, minimum range of 25 to 95 % relativehumidity.6.8 Apparatus specified in CIPAC Test Method MT 187.7. Reagents and Materials7.1 Granular pesticide to be tested.7.2 Reagents and materials specified in C
17、IPAC Test MethodMT 187.8. Hazards8.1 Before testing, read the precautionary statements on theproduct label and the Material Safety Data Sheet (MSDS).Take proper precautions to prevent skin contact and inhalationof the fines. Take care to prevent contamination of thesurrounding area. Always wear the
18、appropriate safety equip-ment and, where indicated, wear respiratory devices approvedby the National Institute of Occupational Safety and Health(NIOSH) for the product being tested.8.2 Storage, handling, and disposal of test pesticides shouldbe done with consideration for health and environmentalsaf
19、ety, and in accordance with federal, state, and local regula-tions.9. Sampling, Test Specimens, and Test Units9.1 See Test Method E 725 for proper sampling practicesand procedures to reduce a gross sample to a representative,suitable size for this test method.10. Preparation of Apparatus10.1 For all
20、 apparatus, see manufacturers instructions forproper calibration, operation, and maintenance.11. Procedure11.1 The test sample should be 15 g, nominal. The exactamount of each sample should be recorded for use in necessarycalculations.11.2 Weigh the test sample to the nearest 0.01 g (15 gnominal) an
21、d record as W (granules plus inherent inhalableparticles).11.3 Weigh the cyclone collection jar to the nearest 0.01 gand record as J1. Attach the jar to the apparatus.11.4 Measure and record the relative humidity of the air thatwill come in contact with the granules. In the absence ofhumidity contro
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME231620032009STANDARDTESTMETHODFORDETERMINATIONOFPARTICLESRESULTINGFROMTHEATTRITIONOFGRANULARPESTICIDES

链接地址:http://www.mydoc123.com/p-530857.html