ASTM E2270-2013 Standard Practice for Periodic Inspection of Building Facades for Unsafe Conditions《对非安全条件下建筑物正面进行周期性检验的标准实施规程》.pdf
《ASTM E2270-2013 Standard Practice for Periodic Inspection of Building Facades for Unsafe Conditions《对非安全条件下建筑物正面进行周期性检验的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2270-2013 Standard Practice for Periodic Inspection of Building Facades for Unsafe Conditions《对非安全条件下建筑物正面进行周期性检验的标准实施规程》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2270 05E2270 13Standard Practice forPeriodic Inspection of Building Facades for UnsafeConditions1This standard is issued under the fixed designation E2270; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of l
2、ast revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This standard practice describescovers methods and procedures for inspection, evaluation, and reporting for periodicins
3、pection of building facades for unsafe conditions. In the context of this standard,practice, unsafe conditions are hazards causedby or resulting from loss of facade material.1.2 This standard practice does not purport to address the nature of deterioration of various building facade materials nor th
4、eperformance of their assemblies. It is the responsibility of the owner to retain a qualified professional who can demonstrateexpertise in the evaluation of various facade materials and their assemblies.1.3 Investigative techniques discussed may be intrusive, disruptive, or destructive. It is the re
5、sponsibility of the qualifiedprofessional to anticipate, advise on the nature of procedures, and to plan for implementing repair as necessary.1.4 It is the responsibility of the specifying authority to establish the usage of this standard practice and to supplement thisstandardpractice with addition
6、al requirements suitable to its local jurisdiction. It is also the responsibility of the specifyingauthority to determine compliance with local licensing regulations and customary practices.1.5 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are
7、mathematicalconversions to SI units that are provided for information only and are not considered standard.1.6 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address allof the safety concerns, if any, associated with its use. It is the res
8、ponsibility of the user of this standard to establish appropriatesafety and health practices and determine the applicability of regulatory limitations prior to use. Awareness of safety andfamiliarity with safe procedures are particularly important for above-ground operations on facades and destructi
9、ve investigativeprocedures, which typically are associated with the work described.2. Referenced Documents2.1 ASTM Standards:2E631 Terminology of Building Constructions3. Terminology3.1 Refer to Terminology E631.3.2 Definitions:3.2.1 categories of facade conditions:3.2.1.1 ordinary maintenancea cond
10、ition identified at the time of inspection that is not characterized as an “unsafe condition”or “requires repair/stabilization,” but requires maintenance.3.2.1.2 requires repair/stabilizationa condition identified at the time of inspection that shall be repaired or stabilized in orderto prevent prog
11、ression into an “unsafe condition” prior to the next scheduled inspection.NOTE 1The immediacy of actions to address conditions requiring repair other than unsafe conditions is highly variable and should be determinedby the owner. Such determination may require more detailed investigation than addres
12、sed herein to assess the urgency of such action.1 This practice is under the jurisdiction ofASTM Committee E06 on Performance of Buildings and is the direct responsibility of Subcommittee E06.55 on Exterior BuildingWall SystemsPerformance of Building Enclosures.Current edition approved March 1, 2005
13、Nov. 1, 2013. Published March 2005November 2013. Originally approved in 2003. Last previous edition approved in 20032005as E2270 03.E2270 05. DOI: 10.1520/E2270-05.10.1520/E2270-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org
14、. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit m
15、ay not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Har
16、bor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.1.3 unsafe conditiona condition identified at the time of inspection of a component or system that presents an imminentthreat of harm, injury, damage, or loss to persons or property.3.2.2 facadeall areas on the exterior of t
17、he building, except for horizontal roof areas. The facade includes all exterior walls,windows, balconies, cornices, parapets, and appurtenances. The facade also includes walls supported at roof level, such aspenthouse walls, chimneys, and so forth.3.2.3 facade agenumber of years since the original C
18、ertificate of Occupancy for building was issued, or since entire facadereplacement.3.2.4 facade inspection categorycategory assigned to building facade based on the facade material, construction, age, andinspection level/extent required, as outlined in Annex A1 of this document.3.2.5 facade inspecti
19、on reporta detailed documentation of qualified professionals findings, observations, discussions,conclusions, and recommendations about the subject building facades.3.2.6 levels of facade inspections:3.2.6.1 detailed inspectionvisual observation from less than 6 ft (1.8 m) and tactile evaluation of
20、facade components,including probing and non-destructive testing to observe concealed conditions of wall construction.3.2.6.2 general inspectionvisual observation of facade components from distances equal to or greater than 6 ft (1.8 m) withor without magnification or remote optical devices.3.2.7 mai
21、ntenance personnelpersonnel who have been involved in maintenance of the subject building facades.3.2.8 non-destructive testing (NDT)a test that causes no significant structural damage to building components.3.2.9 ownerthe owner, agent, manager, or person in charge, of possession, operation, or mana
22、gement of the building, or anycombination thereof.3.2.10 probedisassembly/removal of selective portions of a facade to observe concealed conditions of wall construction.3.2.11 public access areaany sidewalk, street, alley, park, plaza, playground, schoolyard or other area that is open andaccessible
23、to the public, regardless of whether it is publicly or privately owned.3.2.12 qualified inspectora qualified professional or a person working under the direct supervision of a qualified professional.3.2.13 qualified professionalan architect or civil/structural engineer duly licensed. The qualified p
24、rofessional must beknowledgeable of the design, construction, and inspection of building facades, stability, and deterioration mechanisms relating tothe specific materials and assemblies particular to the facade being inspected.3.2.4 qualified inspectora qualified professional or a person working un
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME22702013STANDARDPRACTICEFORPERIODICINSPECTIONOFBUILDINGFACADESFORUNSAFECONDITIONS 安全 条件下 建筑物 正面

链接地址:http://www.mydoc123.com/p-530743.html