《ASTM E2144-2011 Standard Practice for Personal Sampling and Analysis of Endotoxin in Metalworking Fluid Aerosols in Workplace Atmospheres《工作场所大气环境里金属加工流体气溶胶中内毒素的人体取样和分析的标准实施规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2144-2011 Standard Practice for Personal Sampling and Analysis of Endotoxin in Metalworking Fluid Aerosols in Workplace Atmospheres《工作场所大气环境里金属加工流体气溶胶中内毒素的人体取样和分析的标准实施规范》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2144 11An American National StandardStandard Practice forPersonal Sampling and Analysis of Endotoxin inMetalworking Fluid Aerosols in Workplace Atmospheres1This standard is issued under the fixed designation E2144; the number immediately following the designation indicates the year ofo
2、riginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers quantitative methods for the per-sonal
3、sampling and determination of bacterial endotoxin con-centrations in poly-disperse metalworking fluid aerosols inworkplace atmospheres. Users should have fundamentalknowledge of microbiological techniques and endotoxin test-ing.1.2 Users of this practice may obtain personal or areaexposure data of e
4、ndotoxin in metalworking fluid aerosols,either on a short-term or full-shift basis in workplace atmo-spheres.1.3 This practice gives an estimate of the endotoxin con-centration of the sampled atmosphere.1.4 This practice seeks to minimize inter laboratory varia-tion but does not ensure uniformity of
5、 results.1.5 It is anticipated that this practice will facilitate interlaboratory comparisons of airborne endotoxin data from met-alworking fluid atmospheres, particularly metal removal fluidatmospheres, by providing a basis for endotoxin sampling,extraction, and analytical methods.1.6 In 1997, the
6、Occupational Safety and Health Adminis-tration (OSHA) empanelled a Standards Advisory Committeeto make recommendations to the Administration regardingmeasures that the Administration could take to improve thehealth of workers exposed to metalworking fluids. A report tothe Assistant Secretary of Labo
7、r for OSHA was submitted inJuly, 1999. Subcommittee E34.50 believes that the user com-munity would benefit significantly if a standard method wasdeveloped to give the community guidance on a methodologyfor the sampling and analysis of personal airborne endotoxinexposure assessments in facilities usi
8、ng water-miscible metalremoval fluids, based on the LAL assay or other endotoxindetection technologies as they become available.1.7 This practice does not attempt to set or imply limits forpersonal exposure to endotoxin in metalworking fluid aerosolsin workplace environments.1.8 This standard does n
9、ot purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standar
10、ds:2D1356 Terminology Relating to Sampling and Analysis ofAtmospheresD4840 Guide for Sample Chain-of-Custody ProceduresD5337 Practice for Flow Rate Adjustment of PersonalSampling PumpsD6629 Guide for Selection of Methods for Estimating SoilLoss by ErosionE1370 Guide for Air Sampling Strategies for W
11、orker andWorkplace ProtectionE1497 Practice for Selection and Safe Use of Water-Miscible and Straight Oil Metal Removal FluidsE1542 Terminology Relating to Occupational Health andSafety2.2 OSHA Standards:329 CFR 1910.1000 Air Contaminants29 CFR 1910.1450 Occupational Exposure to HazardousChemicals i
12、n Laboratories2.3 Other Documents:Criteria Document for a Recommended Standard: Occupa-tional Exposure to Metalworking Fluids41This practice is under the jurisdiction of ASTM Committee E34 on Occupa-tional Health and Safety and is the direct responsibility of Subcommittee E34.50 onHealth and Safety
13、Standards for Metal Working Fluids.Current edition approved Dec. 1, 2011. Published December 2011. Originallyapproved in 2001. Last previous edition approved in 2007 as E2144 - 01(2007).DOI: 10.1520/E2144-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Custome
14、r Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.acces
15、s.gpo.gov4Available from U.S. Department of Health and Human Services, Public HealthService, Centers for Disease Control and Prevention, National Institute for Occu-pational Safety and Health, 4676 Columbia Pkwy., Cincinnati, OH 45226.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700
16、, West Conshohocken, PA 19428-2959, United States.NIOSH Manual of Analytical Methods (NMAM)43. Terminology3.1 For definitions of terms in this practice relating tosampling and analysis of atmospheres, refer to TerminologyD1356. For definitions of terms in this practice relating tooccupational health
17、 and safety, refer to Terminology E1542.3.2 Definitions of Terms Specific to This Standard:3.2.1 endotoxin, npyrogenic high molar mass lipopoly-saccharide (LPS) complex associated with the cell wall ofgram-negative bacteria.3.2.1.1 DiscussionThough endotoxins are pyrogens, notall pyrogens are endoto
18、xins. Endotoxins are specifically de-tected through a Limulus Amoebocyte Lysate (LAL) test.3.2.2 endotoxin unit (EU), na biological potency unitequivalent to the FDA Reference Standard Endotoxin (RSE).Currently, EC-6 is equivalent to 0.1 ng 3D 1 EU.3.2.3 field blank, nfilter/cassette unit prepared f
19、or sam-pling that is taken to the sampling site and handled in the samemanner as the analytical filter/cassette unit, but that is not a partof the sampling process.3.2.4 Gram-negative bacteria, nprokaryotic cells thathave a complex cell-wall structure that stain characteristicallywhen subjected to t
20、he differential Gram staining procedure.3.2.5 Limulus amebocyte lysate (LAL) assay, na biologi-cal assay that detects endotoxin.3.2.6 metal removal fluids, nthe subset of metal workingfluids that are used for wet machining or grinding to producethe finished part.3.2.6.1 DiscussionThe term most often
21、 refers to straightoils and water-based fluids, such as soluble, semi-synthetic,and synthetic fluids.3.2.7 onset time, ntime required for a change of 200 mOD(optical density) units relative to the initial OD value.3.2.8 personal sampler, na portable sampling instrumentthat is attached to a person to
22、 ascertain the concentration ofspecific constituents in the air in the persons breathing zone.3.2.9 pyrogen-free, adjmaterial(s) devoid of measurableendotoxin activity.3.2.10 pyrogen-free water (PFW), nprocessed water thatis devoid of measurable endotoxin activity.4. Summary of Practice4.1 A known v
23、olume of workplace air in a facility utilizingmetalworking fluids is drawn through a sample filter cassetteunit.4.2 The sample filter is extracted into a pyrogen-free solu-tion to quantitatively release endotoxin absorbed from col-lected metalworking fluid aerosol.4.3 The extract solution is subject
24、ed to quantitative endo-toxin analysis techniques. The measured endotoxin concentra-tion is reported in terms of endotoxin potency units per unitvolume of air sampled.5. Significance and Use5.1 Endotoxins in metalworking fluid aerosols present po-tential respiratory health hazards to workers who inh
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME21442011STANDARDPRACTICEFORPERSONALSAMPLINGANDANALYSISOFENDOTOXININMETALWORKINGFLUIDAEROSOLSINWORKPLACEATMOSPHERES

链接地址:http://www.mydoc123.com/p-530397.html