ASTM E2003-2010(2014) Standard Practice for Fabrication of the Neutron Radiographic Beam Purity Indicators《中子射线照相波束纯度指示计制作的标准实施规程》.pdf
《ASTM E2003-2010(2014) Standard Practice for Fabrication of the Neutron Radiographic Beam Purity Indicators《中子射线照相波束纯度指示计制作的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2003-2010(2014) Standard Practice for Fabrication of the Neutron Radiographic Beam Purity Indicators《中子射线照相波束纯度指示计制作的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2003 10 (Reapproved 2014)Standard Practice forFabrication of the Neutron Radiographic Beam PurityIndicators1This standard is issued under the fixed designation E2003; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the material and fabrication of aBeam Purity Indicator (BPI), which can be used to dete
3、rminethe relative quality of radiographic images produced by direct,thermal neutron radiographic examination.1.2 The values stated in SI units are regarded to be standard.1.3 This standard does not purport to address the safetyconcerns, if any, associated with its use. It is the responsibilityof the
4、 user of this standard to establish appropriate safety andhealth practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E543 Specification for Agencies Performing NondestructiveTestingE545 Test Method for Determining Image Quality i
5、n DirectThermal Neutron Radiographic ExaminationE748 Practices for Thermal Neutron Radiography of Mate-rialsE1316 Terminology for Nondestructive Examinations3. Terminology3.1 Definitions For definitions of terms used in thispractice, see Terminology E1316, Section H.4. Summary of Practice4.1 The BPI
6、 is used for quantitative determination ofthermal neutron radiographic quality. It consists of a polytet-rafluoroethylene block containing two boron nitride disks, twolead disks and two cadmium wires. A key feature of the deviceis the ability to make visual analysis of its image for subjectivequalit
7、y information. Densitometric measurements of the imageof the device permit quantitative determination of radiographiccontrast, low-energy photon contribution, pair productioncontribution, image unsharpness, and information regardingfilm and processing quality.4.2 Neutron radiography practices are di
8、scussed in PracticeE748.5. Significance and Use5.1 The BPI is designed to yield quantitative informationconcerning neutron beam and image system parameters thatcontribute to film exposure and, thereby, affect overall imagequality. For proper measurements of film exposure due to theneutron beam const
9、ituents, the BPI must be fabricated inaccordance with this practice.5.2 This practice shall be followed for the fabrication of allBeam Purity Indicators to be used with Method E545 todetermine image quality in direct thermal neutron radiography.6. Basis of Application6.1 Qualification of Nondestruct
10、ive AgenciesIf specifiedin the contractual agreement, NDT agencies shall be qualifiedand evaluated as described in Practice E543. The applicablerevision of Practice E543 shall be specified in the contractualagreement.6.2 Procedures and TechniquesThe procedures and tech-niques to be utilized shall be
11、 as described in this practice unlessotherwise specified. Specific techniques may be specified in thecontractual agreement.6.3 Reporting Criteria/Acceptance CriteriaReporting cri-teria for the examination results shall be in accordance withSections 9 and 10 unless otherwise specified. Acceptancecrit
12、eria, for example, for reference radiographs, shall bespecified in the contractual agreement.6.4 Reexamination of Repaired/Reworked ItemsReexamination of repaired/reworked items is not addressed inthis practice and, if required, shall be specified in the contrac-tual agreement.7. Beam Purity Indicat
13、or (BPI)7.1 The BPI shall be constructed of polytetrafluoroethylene,cadmium, lead, and boron nitride.1This practice is under the jurisdiction of ASTM Committee E07 on Nonde-structive Testing and is the direct responsibility of Subcommittee E07.05 onRadiology (Neutron) Method.Current edition approved
14、 Oct. 1, 2014. Published November 2014. Originallyapproved in 1998. Last previous edition approved in 2010 as E2003 - 10. DOI:10.1520/E2003-10R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards
15、 volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States17.2 The construction and dimensions shall be as shown inFig. 1.7.3 The BPI may be encased in a frame
16、for easy mounting,but shall not be enclosed in a dust cover nor shall any materialcover either side of the BPI face.7.4 Cadmium and lead shall be at least 99.9 % pure elemen-tal material.7.5 Boron nitride shall be hot-pressed, minimum 40 %elemental boron.7.6 The polytetrafluoroethylene block toleran
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME200320102014STANDARDPRACTICEFORFABRICATIONOFTHENEUTRONRADIOGRAPHICBEAMPURITYINDICATORS 中子 射线 照相

链接地址:http://www.mydoc123.com/p-530027.html