ASTM E1933-2014 Standard Practice for Measuring and Compensating for Emissivity Using Infrared Imaging Radiometers《用红外线成像辐射计测量和补偿辐射率的标准实施规程》.pdf
《ASTM E1933-2014 Standard Practice for Measuring and Compensating for Emissivity Using Infrared Imaging Radiometers《用红外线成像辐射计测量和补偿辐射率的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1933-2014 Standard Practice for Measuring and Compensating for Emissivity Using Infrared Imaging Radiometers《用红外线成像辐射计测量和补偿辐射率的标准实施规程》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1933 99a (Reapproved 2010)E1933 14Standard Test Methods Practice forMeasuring and Compensating for Emissivity Using InfraredImaging Radiometers1This standard is issued under the fixed designation E1933; the number immediately following the designation indicates the year oforiginal adop
2、tion or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover procedures for measuring and compensating for e
3、missivity when measuring the surfacetemperature of a specimen with an infrared imaging radiometer.21.2 The values stated in SI units are to be regarded as the standard.1.3 These test methods may involve use of equipment and materials in the presence of heated or electrically-energizedequipment, or b
4、oth.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced
5、 Documents2.1 ASTM Standards:3E1316 Terminology for Nondestructive Examinations3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 reflected temperaturethe temperature of the energy incident upon and reflected from the measurement surface of thespecimen.3.1.2 surface-modifying mat
6、erialany tape, spray, paint or the like that is used to change the emissivity of the specimen surface.3.2 See also Terminology E1316.4. Summary of Test Method4.1 Two test methods are given for measuring the emissivity of a specimen surface, the contact thermometer method and thenon-contact thermomet
7、er method.4.2 A test method is also given for compensating for the error produced by emissivity using the computer built into an infraredimaging radiometer.5. Significance and Use5.1 The emissivity of a specimen can cause surface temperature measurement errors. Two test methods are provided formeasu
8、ring and compensating for this error source.5.2 These test methods can be used in the field or laboratory, using commonly available materials.5.3 These test methods can be used with any infrared radiometers that have the required computer capabilities.1 These test methods are This practice is under
9、the jurisdiction ofASTM Committee E07 on Nondestructive Testing and is the direct responsibility of Subcommittee E07.10on Specialized NDT Methods.Current edition approved June 1, 2010Oct. 1, 2014. Published November 2010October 2014. Originally approved in 1997. Last previous edition approved in 200
10、5 asE1933 - 99a (2005)(2010).1. DOI: 10.1520/E1933-99AR10.10.1520/E1933-14.2 These test methods procedures are adapted from the Guideline for Measuring and Compensating for Reflected Temperature, Emittance and Transmittance developedby the Infraspection Institute, 425 Ellis Street, Burlington, NJ 08
11、016.3 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended onl
12、y to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versi
13、onof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16. Interferences6.1 Contact Thermometer MethodContact thermometers can act as heat sinks and change the t
14、emperature of the specimen.6.2 Noncontact Thermometer Method:6.2.1 The use of surface-modifying materials can change the heat transfer properties and temperature of the specimen.Any sucherrors can be minimized by applying surface-modifying materials to the smallest area that satisfies the measuremen
15、t accuracyrequirements of the radiometer and infrared thermographer.6.2.2 Before the surface-modifying material is applied to an area of the specimen adjacent to the area where the emissivity isto be measured (as directed in 8.2.4), errors can be minimized by viewing the imager display to ensure tha
16、t both areas have thesame temperature.6.2.3 When removing a surface-modifying material, as directed in 8.2.7, errors can be minimized by ensuring that the surfaceis returned to its original condition.6.3 Both test methods require the specimen to be at a temperature that is at least 10C warmer or coo
17、ler than the ambienttemperature. Potential errors can be minimized by ensuring the stability of the temperature difference between the specimen andthe ambient temperature during the test.Also, the emissivity measurement accuracy can be increased by increasing this temperaturedifference.6.4 The emiss
18、ivity of a specimen may be specific to the temperature of the specimen and the spectral waveband of the infraredimaging radiometer used to make the measurement. Therefore, the temperature of the specimen and the spectral waveband of theradiometer should be noted along with the measured emissivity va
19、lue.6.5 These test methods are valid only for specimens that are opaque in the waveband of the infrared imaging radiometer.6.6 As the emissivity of a specimen decreases, its reflectivity increases. Careful consideration and avoidance of potential errorsources, including the precise determination of
20、reflected temperature in 8.1.3 and 8.2.3, is required to accurately measure theemissivity values of specimens having lower emissivities. For materials with emissivities less than 0.5, radiometric temperaturemeasurements and emissivity measurements may have a high likelihood of error.7. Apparatus7.1
21、Calibrated Infrared Imaging Radiometer, with a built-in computer that allows the infrared thermographer to input reflectedtemperatures and emissivity values.7.2 Tripod, or device to support the infrared imaging radiometer.7.3 A natural or induced means of heating or cooling the specimen at least 10C
22、 above or below the ambient temperature.7.4 The contact thermometer method requires a calibrated contact thermometer.7.5 The noncontact thermometer method requires a surface-modifying material with a known emissivity at a temperature closeto that of the specimen and in the same spectral waveband of
23、the infrared imaging radiometer.NOTE 1For best results, the surface modifying material should have a high emissivity, preferably 0.9 or greater.8. Procedure8.1 Contact Thermometer Method:8.1.1 Place the infrared imaging radiometer on the tripod or support device at the desired location and distance
24、from thespecimen.8.1.2 Point the infrared imaging radiometer at the specimen and focus on the portion where the emissivity is to be measured.8.1.3 Use an appropriate infrared imaging radiometer measurement function (such as spot temperature, crosshairs, or isotherm)to measure and compensate for the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME19332014STANDARDPRACTICEFORMEASURINGANDCOMPENSATINGFOREMISSIVITYUSINGINFRAREDIMAGINGRADIOMETERS

链接地址:http://www.mydoc123.com/p-529852.html