ASTM E1894-2008 Standard Guide for Selecting Dosimetry Systems for Application in Pulsed X-Ray Sources《选择脉冲X射线源用的剂量测定系统的标准指南》.pdf
《ASTM E1894-2008 Standard Guide for Selecting Dosimetry Systems for Application in Pulsed X-Ray Sources《选择脉冲X射线源用的剂量测定系统的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1894-2008 Standard Guide for Selecting Dosimetry Systems for Application in Pulsed X-Ray Sources《选择脉冲X射线源用的剂量测定系统的标准指南》.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1894 08Standard Guide forSelecting Dosimetry Systems for Application in PulsedX-Ray Sources1This standard is issued under the fixed designation E 1894; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、 revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide provides assistance in selecting and usingdosimetry systems in flash X-ray experiments. Both dose anddose-rate
3、techniques are described.1.2 Operating characteristics of flash x-ray sources aregiven, with emphasis on the spectrum of the photon output.1.3 Assistance is provided to relate the measured dose to theresponse of a device under test (DUT). The device is assumedto be a semiconductor electronic part or
4、 system.2. Contents2.1 Section 1: Scope of guide.2.2 Section 2: Outline.2.3 Section 3: Related ASTM and ICRU documents.2.4 Section 4: Definition of terms.2.5 Section 5: Significance and use of this document for theselection of dosimetry systems for use in pulsed x-ray sources.2.6 Section 6: Descript
5、ion of large flash x-ray sources andtheir characteristics.2.7 Section 7: Measurement principles with an emphasis onobtaining absorbed dose measurements for different spectralconditions in the dosimeter, the DUT, and the relationshipbetween them.2.8 Section 8: The primary information in this guide. T
6、heexperimenter will find details on each dosimetry system. Listedare details such as: 1) how the dosimeters works, i.e., physicalprinciples, 2) typical applications or instrumentation configu-rations, 3) advantages, 4) limitations, 5) sensitivity 6) proce-dures for calibration and proper use and fin
7、ally reproducibilityand accuracy.2.9 Section 9: Suggested documentation requirements.2.10 Section 10: Description of how the experimenter de-termines uncertainty in the dosimetry measurements.2.11 Section 11: References.3. Referenced Documents3.1 ASTM Standards:2E 170 Terminology Relating to Radiati
8、on Measurementsand DosimetryE 665 Practice for Determining Absorbed Dose VersusDepth in Materials Exposed to the X-ray Output of FlashX-ray Machines3E 666 Practice for Calculating Absorbed Dose FromGamma or X RadiationE 668 Practice for Application of Thermoluminescence-Dosimetry (TLD) Systems for D
9、eterminingAbsorbed Dosein Radiation-Hardness Testing of Electronic DevicesE 1249 Practice for Minimizing Dosimetry Errors in Radia-tion Hardness Testing of Silicon Electronic Devices UsingCo-60 SourcesE 1261 Guide for Selection and Calibration of DosimetrySystems for Radiation Processing3E 1275 Prac
10、tice for Use of a Radiochromic Film DosimetrySystem3E 1310 Practice for Use of a Radiochromic OpticalWaveguide Dosimetry System33.2 International Commission on Radiation Units (ICRU)and Measurements Reports:4ICRU Report 14 Radiation Dosimetry: X rays and GammaRays with Maximum Photon Energies Betwee
11、n 0.6 and 50MeVICRU Report 17 Radiation Dosimetry: X rays Generated atPotentials of 5 to 150 kV1This practice is under the jurisdiction of ASTM Committee E10 on NuclearTechnology and Applications and is the direct responsibility of SubcommitteeE10.07 on Radiation Dosimetry for Radiation Effects on M
12、aterials and Devices.Current edition approved Sept. 15, 2008. Published November 2008. Originallyapproved in 1997. Last previous edition approved in 2002 as E 1894 97 (2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For
13、Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.4Available from the International Commission on Radiation Units and Measure-ments, 7910 Wood
14、mont Ave., Suite 800, Bethesda, MD 20814, U.S.A.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.ICRU Report 33 Radiation Quantities and UnitsICRU Report 34 The Dosimetry of Pulsed Radiation4. Terminology4.1 absorbed dosequotient of d
15、e/dm, where de is themean energy imparted by ionizing radiation to matter of massdm:D 5ddme (1)See ICRU Report 33. The special name for the unit forabsorbed dose is the gray (Gy).1Gy5 1J/kg (2)Formerly, the special unit for absorbed dose was the rad,where 1 rad = 100 erg/g.1 rad 5 0.01 Gy (3)Because
16、 the magnitude of the absorbed dose is materialdependent, it is important to include the material compositionfor which the dose is being reported, e.g., 15.3 Gy(LiF).4.2 absorbed dose enhancementincrease (or decrease) inthe absorbed dose (as compared to the equilibrium absorbeddose) at a point in a
17、material of interest. This can be expectedto occur near an interface with a material of higher or loweratomic number.4.3 convertera target for electron beams, generally of ahigh atomic number material, in which bremsstrahlung X raysare produced by radiative energy losses of the incident elec-trons.4
18、.4 dosimetera device that, when irradiated, exhibits aquantifiable change in some property of the device which canbe related to absorbed dose in a given material using appro-priate analytical instrumentation and techniques.4.5 dosimetry systemA system used for determining ab-sorbed dose, consisting
19、of dosimeters, measurement instru-ments, and their associated reference standards, and proceduresfor the systems use.4.6 DUTdevice under test. This is the electronic compo-nent or system tested to determine its performance during orafter irradiation.4.7 endpoint energyendpoint energy refers to the p
20、eakenergy of the electron beam, usually in MeV, generated in aflash X-ray source and is numerically equal to the maximumvoltage in MV. The word endpoint refers to the highest photonenergy of the bremsstrahlung spectra, and this endpoint isequal to the maximum or peak in the electron energy. Forexamp
21、le, if the most energetic electron that strikes the con-verter is 10 MeV, this electron produces a range of bremsstrahl-ung photon energies but the maximum energy of any photon isequal to 10 MeV, the endpoint energy. Most photons haveenergies one-tenth to one-third of the maximum electronenergy for
22、typical flash X-ray sources in the 10 MV to 1 MVendpoint voltage region, respectively.4.8 endpoint voltageEndpoint voltage refers to the peakvoltage across a bremsstrahlung diode in a flash X-ray source.For example, a 10-MV flash X-ray source is designed to reacha peak voltage of 10-MV across the an
23、ode-cathode gap whichgenerates the electron beam for striking a converter to producebremsstrahlung.4.9 equilibrium absorbed doseabsorbed dose at someincremental volume within the material in which the conditionof electron equilibrium (the energies, number, and direction ofcharged particles induced b
24、y the radiation are constantthroughout the volume) exists. For lower energies wherebremsstrahlung production is negligible the equilibrium ab-sorbed dose is equal to the kerma.NOTE 1For practical purposes, assuming the spatial gradient in theX-ray field is small over the range of the maximum energy
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME18942008STANDARDGUIDEFORSELECTINGDOSIMETRYSYSTEMSFORAPPLICATIONINPULSEDXRAYSOURCES 选择 脉冲 射线 剂量 测定

链接地址:http://www.mydoc123.com/p-529748.html