ASTM E1805-2013 Standard Test Method for Determination of Gold in Copper Concentrates by Fire Assay Gravimetry《用燃烧鉴定重量测定法测定铜精矿中金的标准试验方法》.pdf
《ASTM E1805-2013 Standard Test Method for Determination of Gold in Copper Concentrates by Fire Assay Gravimetry《用燃烧鉴定重量测定法测定铜精矿中金的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1805-2013 Standard Test Method for Determination of Gold in Copper Concentrates by Fire Assay Gravimetry《用燃烧鉴定重量测定法测定铜精矿中金的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1805 13Standard Test Method forDetermination of Gold in Copper Concentrates by FireAssay Gravimetry1This standard is issued under the fixed designation E1805; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year o
2、f last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is for the determination of gold incopper concentrates in the content range from 0.2 g/g to 17g/g.N
3、OTE 1The lower scope limit is set in accordance with PracticeE1601.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It
4、is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificwarning statements, see 11.3.1, 11.5.4, and 11.6.5.2. Referenced Documents2.1 ASTM Standards:2D1193 Specificati
5、on for Reagent WaterE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE50 Practices for Apparatus, Reagents, and Safety Consid-erations for Chemical Analysis of Metals, Ores, andRelated MaterialsE135 Terminology Relating to Analytical Chemistry forMeta
6、ls, Ores, and Related MaterialsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE882 Guide for Accountability and Quality Control in theChemical Analysis LaboratoryE1601 Practice for Conducting an Interlaboratory Study toEvaluate the Performance of an A
7、nalytical Method3. Terminology3.1 For definitions of terms used in this test method, refer toTerminology E135.4. Summary of Test Method4.1 A test sample of copper concentrate is fluxed and fusedin a clay crucible. The precious metals are reduced, collected ina lead button, and then cupelled to remov
8、e the lead. Theremaining dor bead is parted with nitric acid to remove thesilver and other impurities from the gold. The gold is thenannealed, cleaned, and weighed on a microbalance.5. Significance and Use5.1 In the metallurgical process used in the miningindustries, gold is often carried along with
9、 copper during theflotation concentration process. Metallurgical accounting, pro-cess control, and concentrate evaluation procedures for thistype of material depend on an accurate, precise measurementof the gold in the copper concentrate. This test method isintended to be a reference method for meta
10、llurgical laborato-ries and a referee method to settle disputes in commercialtransactions. It is also a definitive method intended to testmaterials for compliance with compliance with compositionalspecifications and to provide data for certification of referencematerials. It is essential that each p
11、erformance of the methodbe validated by applying it to appropriate reference materials atthe same time and in the same manner as it is applied to theunknowns.5.2 It is assumed that all who use this test method will betrained analysts capable of performing skillfully and safely. Itis expected that th
12、e work will be performed in a properlyequipped laboratory under appropriate quality control practicessuch as those described in Guide E882.6. Interferences6.1 Elements normally found in copper concentrates withinthe limits of 1.1 do not interfere. High concentrations ofarsenic, antimony, tellurium,
13、bismuth, nickel, and platinumgroup metals (and, in some instances, copper), however, mayinterfere with the fusion and cupellation steps.1This test method is under the jurisdiction of ASTM Committee E01 onAnalytical Chemistry for Metals, Ores, and Related Materials and is the directresponsibility of
14、Subcommittee E01.02 on Ores, Concentrates, and Related Metal-lurgical Materials.Current edition approved April 1, 2013. Published June 2013. Originallyapproved in 1996. Last previous edition approved in 2007 as E1805 - 07. DOI:10.1520/E1805-13.2For referenced ASTM standards, visit the ASTM website,
15、www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States17.
16、Apparatus7.1 Analytical Balance, capable of weighing to 0.1 g.7.2 Assay Mold, 100-mL capacity.7.3 Cube or Cone Mixer, 1000-g capacity.7.4 Cupel, magnesite or bone ash, 40-g lead capacity.7.5 Drying Oven, forced air circulation with temperaturecontrol, 104 C.7.6 Fire Assay Bead Brush.7.7 Fire Assay B
17、ead Pliers.7.8 Fire Assay Clay Crucible, 20-g to 30-g sample capacity.7.9 Fire Assay Muffle Furnace, gas-fired or electric,equipped with air circulation systems and with draft controls,capable of temperatures to 1100 C 6 10 C, and withventilation controls for acid and lead fumes.7.10 Fire Assay Tong
18、s, crucible and cupel.7.11 Fire Assay Tumble Mixeran industrial mixer-crucibletumbler.7.12 Hot Plate, with variable temperature control and ven-tilation controls for acid fumes.7.13 Jaw Crusher, capable of reducing cupels and slag topass a 4-mm sieve.7.14 Ring Pulverizer, capable of 250-g minimal ca
19、pacity.7.15 Semi-Microbalance, capable of weighing to 0.001 mg.7.16 Steel Hammer.8. Reagents and Materials8.1 Borax Glass (Na2B4O7).8.2 Cupel Correction FluxBlend the following ingredi-ents in the listed proportions:Borax Glass 15 gFlour 2 gLead Oxide 30 gPotassium Carbonate 45 gSilica 12 g8.3 Fire
20、Assay Flux MixtureBlend the following ingredi-ents in the listed proportions:Borax Glass 15 gLead Oxide 55 gPotassium Carbonate 6 gPotassium Nitrate 13 gSilica 6 gSodium Carbonate 20 gNOTE 2Perform a preliminary fusion to determine lead button weight.If a 30-g to 40-g lead button is not obtained, ad
21、just the amount of KNO3and try again. Increasing the KNO3produces a smaller lead button, anddecreasing the KNO3produces a larger one.8.4 Flour, ground wheat.8.5 Lead Oxide, Litharge, (PbO)Containing less than 0.02g/g gold and less than 0.40 g/g silver.8.6 Potassium Carbonate, Potash (K2CO3).8.7 Pota
22、ssium Nitrate, Niter (KNO3).8.8 Silica (SiO2), 95 % minimum purity, particle size lessthan 180 m.8.9 Silver Foil, 99.9 % purity with less than 0.10 g/g goldcontent.8.10 Silver Solution (1 g/L)Add 1.557 g silver nitrate to1000 mL of water containing 5 mL of HNO3, mix. Store in adark bottle.8.11 Sodiu
23、m Carbonate, Soda Ash (Na2CO3), anhydroustechnical grade.8.12 Sodium Chloride, salt (NaCl).8.13 Purity of ReagentsUse reagent grade chemicals in alltests. Unless otherwise indicated, all reagents conform to thespecifications of the Committee on Analytical Reagents of theAmerican Chemical Society whe
24、re such specifications areavailable. Other grades may be used provided it is firstascertained that the reagents are of sufficiently high purity topermit their use without lessening the accuracy of the deter-mination.38.14 Purity of WaterUnless otherwise indicated, refer-ences to water shall be under
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME18052013STANDARDTESTMETHODFORDETERMINATIONOFGOLDINCOPPERCONCENTRATESBYFIREASSAYGRAVIMETRY 燃烧 鉴定

链接地址:http://www.mydoc123.com/p-529509.html