ASTM E1692-1995a(2012) Standard Classification for Serviceability of an Office Facility for Change and Churn by Occupants《对人员变动和工作人员有剧烈活动的办工设备的适用性标准分类》.pdf
《ASTM E1692-1995a(2012) Standard Classification for Serviceability of an Office Facility for Change and Churn by Occupants《对人员变动和工作人员有剧烈活动的办工设备的适用性标准分类》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1692-1995a(2012) Standard Classification for Serviceability of an Office Facility for Change and Churn by Occupants《对人员变动和工作人员有剧烈活动的办工设备的适用性标准分类》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1692 95a (Reapproved 2012)An American National StandardStandard Classification forServiceability of an Office Facility for Change and Churn byOccupants1This standard is issued under the fixed designation E1692; the number immediately following the designation indicates the year oforigi
2、nal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This classification covers pairs of scales for classifyingan asp
3、ect of the serviceability of an office facility, that is, thecapability of an office facility to meet certain possible require-ments to accommodate changes in working method, andfrequent relocations of staff, and realignment of workstations.1.2 Each pair of scales shown in Figs. 1-5, printed side by
4、side on a page, are for classifying one topic of serviceabilitywithin that aspect of serviceability. Each paragraph in anOccupant Requirement Scale (see Figs. 1-5) summarizes onelevel of serviceability on that topic that occupants mightrequire. The matching entry in the Facility Rating Scale (see)is
5、 a translation of the requirement into a description of certainfeatures of a facility that, taken in combination, indicate thatthe facility is likely to meet that level of required serviceability.1.3 The entries in the Facility Rating Scale (see Figs. 1-5)are indicative and not comprehensive. They a
6、re for quickscanning, to estimate approximately, quickly, and economi-cally how well an office facility is likely to meet the needs ofone or another type of occupant group over time. The entriesare not for measuring, knowing, and evaluating how an officefacility is performing.1.4 This classification
7、 can be used to estimate the level ofserviceability of an existing facility. It can also be used toestimate the serviceability of a facility that has been plannedbut not yet built, such as one for which single-line drawingsand outline specifications have been prepared.1.5 This classification indicat
8、es what would cause a facilityto be rated at a certain level of serviceability, but it does notstate how to conduct a serviceability rating or how to assign aserviceability score. That information is found in PracticeE1334. The scales in this classification are complementary toand compatible with Pr
9、actice E1334. Each requires the other.2. Referenced Documents2.1 ASTM Standards:2E631 Terminology of Building ConstructionsE1334 Practice for Rating the Serviceability of a Buildingor Building-Related FacilityE1679 Practice for Setting the Requirements for the Ser-viceability of a Building or Buildi
10、ng-Related Facility2.2 ISO Documents:3ISO 6240 International Standard, PerformancemStandardsin BuildingContents and PresentationISO/DIS 7162 Draft International Standard, PerformanceStandards in BuildingContents and Format of Standardsfor Evaluation of PerformanceISO/DIS 7164 Draft International Sta
11、ndard, PerformanceStandards in BuildingDefinitions and Means of Expres-sion for the Performance of a Whole Building3. Terminology3.1 Definitions:3.1.1 For standard definitions of additional terms applicableto this classification, see Terminology E631.3.1.2 facility, nphysical setting used to serve a
12、 specificpurpose. E6313.1.2.1 DiscussionA facility may be within a building, ora whole building, or a building with its site and surroundingenvironment; or it may be a construction that is not a building.The term encompasses both the physical object and its use.3.1.3 facility serviceabilitythe capab
13、ility of a facility toperform the function(s) for which it is designed, used, or1This classification is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.25on Whole Buildings and Facilities.Current edition approved April 1, 2
14、012. Published May 2012. Originallyapproved in 1995. Last previous edition approved in 2005 as E1692 95a (2005).DOI: 10.1520/E1692-95AR12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume
15、information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2
16、959, United States.required to be used. E6313.1.3.1 DiscussionThe scope of this performance is of thefacility as a system, including its subsystems, components, andmaterials and their interactions, such as acoustical, hydrother-mal, air purity, and economic; and of the relative importance ofeach per
17、formance requirement.3.1.4 offcea place, such as a room, suite, or building, inwhich business, clerical, or professional activities are con-ducted. E6313.2 Definitions of Terms Specific to This Standard:3.2.1 churn ratethe rate at which changes in the layout orlocation of individual workstations occ
18、ur in an organization,calculated as the number of occasions during the year in whichthe location at which an individual works is changed, or aworkstation was relocated, including realignments or moveswithin the building, and moves in or out of the facility, with thetotal being divided by the total n
19、umber of occupants at the endof the year and expressed as a percentage.3.2.1.1 DiscussionThe workstation that is relocated maybe as an individuals workstation or a workstation that is sharedby a workgroup or project team. The relocation may require themovement of furniture screens or of partition wa
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME16921995A2012STANDARDCLASSIFICATIONFORSERVICEABILITYOFANOFFICEFACILITYFORCHANGEANDCHURNBYOCCUPANTS

链接地址:http://www.mydoc123.com/p-529251.html