ASTM E1684 E1684M-2015 Standard Specification for Miniature Thermocouple Connectors《微型热电偶连接器的标准规格》.pdf
《ASTM E1684 E1684M-2015 Standard Specification for Miniature Thermocouple Connectors《微型热电偶连接器的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1684 E1684M-2015 Standard Specification for Miniature Thermocouple Connectors《微型热电偶连接器的标准规格》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1684 10E1684/E1684M 15Standard Specification forMiniature Thermocouple Connectors1This standard is issued under the fixed designation E1684;E1684/E1684M; the number immediately following the designation indicatesthe year of original adoption or, in the case of revision, the year of las
2、t revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers separable single-circuit miniature thermocouple connectors with two flat pins. Connectors cover
3、edby this specification must be rated for continuous use to at least 300F (150C), but they may optionally be rated higher.to a highertemperature.1.2 This specification does not cover multiple-circuit connectors, multi-pin connectors, standard size connectors, or connectorsintended primarily for pane
4、l mounting. High-temperature connectors (for example, those designed for continuous use attemperatures significantly above approximately 500F (260C)260C) are not intended to be covered by this specification.1.3 The values stated in either SI units or inch-pound units are to be regarded separately as
5、 the standard. The values stated inbrackets are not conversions to the values they succeed and therefore shall be used independently of the preceding values. Thevalues given in parentheses are for information only.conversions of the values they succeed. Combining values from the twosystems may resul
6、t in non-conformance with the standard.1.4 The plug and jack may be ordered separately but many of the connector characteristics (see Table 1) are qualified as a matedpair. The requirements in this standard are applicable for the connector pair supplied by the same manufacturer.1.5 The following pre
7、cautionary statement pertains only to the test methodsTest Methods portion, Section 9, of thisspecification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appropriate safety and
8、 health practices and determine the applicability ofregulatory limitations prior to use.2. Referenced Documents2.1 The following documents of the latest issue form a part of this specification to the extent referenced herein. In case ofconflict between this specification and another referenced docum
9、ent, this specification shall take precedence.2.2 ASTM Standards:2E230E230/E230M Specification and Temperature-Electromotive Force (EMF)(emf) Tables for Standardized ThermocouplesE344 Terminology Relating to Thermometry and HydrometryE2820 Test Method for Evaluating Thermal EMF Properties of Base-Me
10、tal Thermocouple Connectors3. Terminology3.1 DefinitionsThe definitions given in Terminology E344 shall apply.3.2 Definitions of Terms Specific to This Standard:3.2.1 connector pair, nassembly consisting of a plug and a jack, each having both positive and negative inserts, that willconnect two parts
11、 of an electrical circuit and provide a means of physically disconnecting the two parts without the use of tools.atool.3.2.2 contact insert, nmetallic conductor assemblies that, when installed in connector bodies, provide connections betweentwo parts of an electrical circuit. Plug connectors will co
12、ntain projecting prong contacts, while jack connectors will containrecessed socket or receptacle contacts.1 This specification is under the jurisdiction of ASTM Committee E20 on Temperature Measurement and is the direct responsibility of Subcommittee E20.04 onThermocouples.Current edition approved N
13、ov. 1, 2010Dec. 1, 2015. Published December 2010January 2016. Originally approved in 1995. Last previous edition approved in 20052010as E1684 05.E1684 10. DOI: 10.1520/E1684-10.10.1520/E1684-15.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at se
14、rviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version
15、. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International,
16、 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.3 service life, nintervalperiod of time that over which a connector assembly willcan be put to use and retain all physicaland thermoelectric properties.3.2.4 test difference, napparent thermoelectric difference
17、emf value attributable to mated connectors observed by the testprocedure of this specification.4. Significance and Use4.1 The widespread use of thermocouple connectors requires standardization of mating dimensions and performancecharacteristics.4.2 This specification describes miniaturizedminiature
18、thermocouple connector dimensions and capabilities and includes testprocedures suitable for evaluating the performance of a particular specimen or design. The tests described are not intended forroutine inspection or rapid testing of large groups of connectors or for quality control purposes.5. Clas
19、sification5.1 Plugs or Jacks:5.1.1 Connectors shall be constructed as either plugs or jacks, and these two forms shall be designed to connect with each other.5.1.2 Plug connectors shall have two external prong contacts of differing sizesdifferent dimensions to prevent improper mating.The negative pr
20、ong shall be the wider, as indicated in Table 2 and Fig. 1.5.1.3 Jack connectorconnectors shall have two internal socket contacts sized and spaced to receive and accommodate the prongcontacts of the mating plug. Jack connectors shall also include a means of producing and maintaining sufficient conta
21、ct pressureto meet all the other requirements of this specification.5.2 ANSI/ASTM Type:5.2.1 Connectors shall be produced in versions to match each of the standardized ANSI/ASTM thermocouple types as given inTable 3.TABLE 1 RatingsCharacteristic min maxOperating temperature 0F (-18C) 300F (150C)Cont
22、act resistance (each leg) . 0.04 Insulation resistance at room temperature 107 .Insulation resistance at 300 F (150 C) 106 .Test difference . 2F (1.1C)Repeated coupling cycles (coupled oruncoupled)25 .Service life 5000 h .Withdraw force 8 oz .TABLE 1 RatingsCharacteristic Min Max Requirement Test Pr
23、ocedureOperating temperature 0F -18C 300F 150C 7.1.2 9.7Contact resistance (each leg) . 0.04 7.2.6 9.2Insulation resistance at room temperature 107 . 7.3.4 9.4Insulation resistance at 300 F (150 C) 106 . 7.3.4 9.4Thermal gradient test difference . 2F 1.1C 7.2.7 9.3Repeated cycles 25 . 7.2.4 9.6Servi
24、ce life 5000 h . 7.3.5 9.7Disengagement force 8 ozf 2.2 N . 7.2.3 9.5TABLE 2 DimensionsDimension SymbolA Minimum Size,in. (mm) Maximum Size,in. (mm)Plug body length PL . 0.788 (20.00)Jack body length JL . 1.069 (27.13)Body width W . 0.635 (16.10)Body thickness T . 0.385 (9.78)Length of prong P 0.406
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME1684E1684M2015STANDARDSPECIFICATIONFORMINIATURETHERMOCOUPLECONNECTORS 微型 热电偶 连接器 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-529229.html