《ASTM E1666-1995a(2005) Standard Classification for Serviceability of an Office Facility for Work Outside Normal Hours or Conditions《办公设备对于正常时间或条件以外的工作的适用性标准分类》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1666-1995a(2005) Standard Classification for Serviceability of an Office Facility for Work Outside Normal Hours or Conditions《办公设备对于正常时间或条件以外的工作的适用性标准分类》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1666 95a (Reapproved 2005)An American National StandardStandard Classification forServiceability of an Office Facility for Work Outside NormalHours or Conditions1, 2This standard is issued under the fixed designation E 1666; the number immediately following the designation indicates t
2、he year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This classification covers pairs of scales for c
3、lassifyingan aspect of the serviceability of an office facility, that is, thecapability of an office facility to meet certain possible require-ments to be able to do normal office tasks outside scheduledhours.1.2 Within that aspect of serviceability, each pair of scales,shown in Figs. 1-4, are for c
4、lassifying one topic of serviceabil-ity. Each paragraph in an Occupant Requirement Scale (seeFigs. 1-4) summarizes one level of serviceability on that topic,which occupants might require. The matching entry in theFacility Rating Scale (see Figs. 1-4) is a translation of therequirement into a descrip
5、tion of certain features of a facilitywhich, taken in combination, indicate that the facility is likelyto meet that level of required serviceability.1.3 The entries in the Facility Rating Scale (see Figs. 1-4)are indicative and not comprehensive. They are for quickscanning to estimate approximately,
6、 quickly, and economically,how well an office facility is likely to meet the needs of one oranother type of occupant group over time. The entries are notfor measuring, knowing, or evaluating how an office facility isperforming.1.4 This classification can be used to estimate the level ofserviceabilit
7、y of an existing facility. It can also be used toestimate the serviceability of a facility that has been plannedbut not yet built, such as one for which single-line drawingsand outline specifications have been prepared.1.5 This classification indicates what would cause a facilityto be rated at a cer
8、tain level of serviceability, but does not statehow to conduct a serviceability rating nor how to assign aserviceability score. That information is found in PracticeE 1334. The scales in this classification are complimentary toand compatible with Practice E 1334. Each requires the other.2. Reference
9、d Documents2.1 ASTM Standards:3E 631 Terminology of Building ConstructionsE 1334 Practice for Rating Serviceability of a Building orBuilding-Related FacilityE 1679 Practice for Setting Requirements for Serviceabilityof a Building or Building-Related Facility2.2 ISO Document:4ISO 6240 International S
10、tandard, Performance Standards inBuildingContents and Presentation3. Terminology3.1 Definitions:3.1.1 facilitya physical setting used to serve a specificpurpose. E 6313.1.1.1 DiscussionA facility may be within a building, awhole building, or a building with its site and surroundingenvironment; or it
11、 may be a construction that is not a building.The term encompasses both the physical object and its use.3.1.2 facility serviceabilitythe capability of a facility toperform the function(s) for which it is designed, used, orrequired to be used. E 6313.1.2.1 DiscussionThe scope of this performance is o
12、f thefacility as a system, including its subsystems, components andmaterials and their interactions, such as acoustical, hydrother-mal, air purity, and economic; and of the relative importance ofeach performance requirement.3.1.3 offcea place, such as a room, suite, or building, inwhich business, cl
13、erical or professional activities are con-ducted. E 6313.1.4 For standard definitions of additional terms applicableto this classification, see Terminology E 631.3.2 Definitions of Terms Specific to This Standard:3.2.1 hours of operation:3.2.1.1 active hoursthe time when a facility is normallyfully
14、occupied and operational.1This classification is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.25on Whole Buildings and Facilities.Current edition approved May 1, 2005. Published May 2005. Originallyapproved in 1995. Last
15、 previous edition approved in 1999 as E 1666 95a (1999).2Portions of this document are based on material originally prepared by theInternational Centre for Facilities (ICF) and r 1993 by ICF and Minister of PublicWorks and Government Services Canada. Their cooperation in the development ofthis stand
16、ard is acknowledged.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from American National Standar
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME16661995A2005STANDARDCLASSIFICATIONFORSERVICEABILITYOFANOFFICEFACILITYFORWORKOUTSIDENORMALHOURSORCONDITIONS

链接地址:http://www.mydoc123.com/p-529177.html