ASTM E1664-1995a(2018) Standard Classification for Serviceability of an Office Facility for Layout and Building Factors《办公设施布局和建筑因素适用性的标准分类》.pdf
《ASTM E1664-1995a(2018) Standard Classification for Serviceability of an Office Facility for Layout and Building Factors《办公设施布局和建筑因素适用性的标准分类》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1664-1995a(2018) Standard Classification for Serviceability of an Office Facility for Layout and Building Factors《办公设施布局和建筑因素适用性的标准分类》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1664 95a (Reapproved 2018) An American National StandardStandard Classification forServiceability of an Office Facility for Layout and BuildingFactors1,2This standard is issued under the fixed designation E1664; the number immediately following the designation indicates the year oforig
2、inal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This classification covers pairs of scales for classifyingan as
3、pect of the serviceability of an office facility, that is, thecapability of an office facility to meet certain possible require-ments for layout and building factors.1.2 Within that aspect of serviceability, each pair of scales,shown in Figs. 1-3, are for classifying one topic of serviceabil-ity. Ea
4、ch paragraph in an Occupant Requirement Scale (seeFigs. 1-3) summarizes one level of serviceability on that topic,which occupants might require. The matching entry in theFacility Rating Scale (see Figs. 1-3) is a translation of therequirement into a description of certain features of a facilitywhich
5、, taken in combination, indicate that the facility is likelyto meet that level of required serviceability.1.3 The entries in the Facility Rating Scale (see Figs. 1-3)are indicative and not comprehensive. They are for quickscanning to estimate approximately, quickly, and economically,how well an offi
6、ce facility is likely to meet the needs of one oranother type of occupant group over time. The entries are notfor measuring, knowing, or evaluating how an office facility isperforming.1.4 This classification can be used to estimate the level ofserviceability of an existing facility. It can also be u
7、sed toestimate the serviceability of a facility that has been plannedbut not yet built, such as one for which single-line drawingsand outline specifications have been prepared.1.5 This classification indicates what would cause a facilityto be rated at a certain level of serviceability but does not s
8、tatehow to conduct a serviceability rating nor how to assign aserviceability score. That information is found in PracticeE1334. The scales in this classification are complimentary toand compatible with Practice E1334. Each requires the other.1.6 The values stated in SI units are to be regarded assta
9、ndard. The values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.7 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in th
10、e Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:3E631 Terminology of Building ConstructionsE1334 Practice for Rating the Ser
11、viceability of a Building orBuilding-Related Facility (Withdrawn 2013)4E1679 Practice for Setting the Requirements for the Service-ability of a Building or Building-Related Facility, and forDetermining What Serviceability is Provided or Proposed2.2 ISO Document:5ISO 6240 International Standard, Perf
12、ormance Standards inBuildingContents and Presentation2.3 ASHRAE Standard:6ASHRAE 62-89 Ventilation forAcceptable IndoorAir Qual-ity2.4 ANSI Document:5ANSI Z65.1 Method for Measuring Floor Area in OfficeBuildings1This classification is under the jurisdiction of ASTM Committee E06 onPerformance of Bui
13、ldings and is the direct responsibility of Subcommittee E06.25on Whole Buildings and Facilities.Current edition approved March 1, 2018. Published March 2018. Originallyapproved in 1995. Last previous edition approved in 2012 as E1664 95a (2012).DOI: 10.1520/E1664-95AR18.2Portions of this document ar
14、e based on material originally prepared by theInternational Centre for Facilities (ICF) and 1993 by ICF and Minister of PublicWorks and Government Services Canada. Their cooperation in the development ofthis standard is acknowledged.3For referenced ASTM standards, visit the ASTM website, www.astm.or
15、g, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4The last approved version of this historical standard is referenced onwww.astm.org.5Available from American National Standards
16、Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.6Available from American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. (ASHRAE), 1791 Tullie Circle, NE, Atlanta, GA30329, http:/www.ashrae.org.Copyright ASTM International, 100 Barr Harbor D
17、rive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations
18、issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1FIG. 1 Scale A.7.1 for Influence of HVAC on LayoutE1664 95a (2018)2FIG. 1 Scale A.7.1 for Influence of HVAC on Layout (continued)E1664 95a (2018)3FIG. 2 Scale A.7.2 for the Influence of Sound and Visual Factors on La
19、youtE1664 95a (2018)4FIG. 2 Scale A.7.2 for the Influence of Sound and Visual Factors on Layout (continued)E1664 95a (2018)5FIG. 3 Scale A.7.3 for the Influence of Building Loss Factors on Space NeedsE1664 95a (2018)63. Terminology3.1 Definitions:3.1.1 facilitya physical setting used to serve a spec
20、ificpurpose. E6313.1.1.1 DiscussionA facility may be within a building, awhole building, or a building with its site and surroundingenvironment; or it may be a construction that is not a building.The term encompasses both the physical object and its use.3.1.2 facility serviceabilitythe capability of
21、 a facility toperform the function(s) for which it is designed, used, orrequired to be used. E6313.1.2.1 DiscussionThe scope of this performance is of thefacility as a system, including its subsystems, components andmaterials and their interactions, such as acoustical,hydrothermal, air purity, and e
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME16641995A2018STANDARDCLASSIFICATIONFORSERVICEABILITYOFANOFFICEFACILITYFORLAYOUTANDBUILDINGFACTORS

链接地址:http://www.mydoc123.com/p-529173.html