ASTM E1573-2009 Standard Test Method for Evaluating Masking Sound in Open Offices Using A-Weighted and One-Third Octave Band Sound Pressure Levels《用A计权和1 3倍频带声压级评价敞开式办公室间掩蔽声的标准试验方法.pdf
《ASTM E1573-2009 Standard Test Method for Evaluating Masking Sound in Open Offices Using A-Weighted and One-Third Octave Band Sound Pressure Levels《用A计权和1 3倍频带声压级评价敞开式办公室间掩蔽声的标准试验方法.pdf》由会员分享,可在线阅读,更多相关《ASTM E1573-2009 Standard Test Method for Evaluating Masking Sound in Open Offices Using A-Weighted and One-Third Octave Band Sound Pressure Levels《用A计权和1 3倍频带声压级评价敞开式办公室间掩蔽声的标准试验方法.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1573 09Standard Test Method forEvaluating Masking Sound in Open Offices UsingA-Weighted and One-Third Octave Band Sound PressureLevels1This standard is issued under the fixed designation E 1573; the number immediately following the designation indicates the year oforiginal adoption or
2、, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis test method is one of a set of standards for evaluating the acoustical per
3、formance ofcomponents or systems in an open office. The other standards in this set deal with the measurementof the sound attenuation between work stations provided by partial height space dividers, verticalsurfaces, and acoustical ceiling systems; speech privacy; and the evaluation of masking sound
4、.1. Scope1.1 This test method specifies the procedures that can beused to evaluate the spatial and temporal uniformity ofmasking sound in open offices using A-weighted sound levels.It also specifies the procedure for evaluating the masking soundspectrum and level using one-third octave band sound pr
5、essurelevels.1.2 The results of this test method can be used to determineif the masking sound meets a particular specification for spatialand temporal uniformity if that specification is written in termsof A-weighted sound levels and if the masking sound meets aparticular spectrum shape and level in
6、 the office area.1.3 This test method must not be used to evaluate theacoustical environment in an office space. It is intended only toevaluate the masking sound in an office. This test method, forinstance, does not evaluate the low frequency rumble noisefound in some offices.1.4 This standard does
7、not purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standa
8、rds:2C 634 Terminology Relating to Building and Environmen-tal AcousticsE 1374 Guide for Open Office Acoustics and ApplicableASTM Standards2.2 ANSI Standards:3S1.11 2004 Specification for Octave-Band and Fractional-Octave Band Analog and Digital FiltersS1.43 1997 (R 2007) Specifications for integrat
9、ing aver-aging sound level metersIEC 61672 2002 Electroacoustics- Sound Level meters-part 1: specifications3. Terminology3.1 DefinitionsThe acoustical terminology used in thistest method is consistent with the definitions in TerminologyC 634.3.2 Definitions of Terms Specific to This Standard:3.2.1 m
10、asking soundsound within an office that reducesthe intelligibility of intruding speech and the distraction fromactivity noise. Masking sound may be produced by a maskingsound system, heating, ventilating, and air conditioning(HVAC) sources, or other sources.3.2.2 masking sound systemthe electronic e
11、quipment andloudspeakers used to generate, distribute, and produce maskingsound throughout an office space.3.2.3 spatial uniformitya condition where the sound pres-sure levels throughout a defined space do not vary significantlyfrom the arithmetic mean sound pressure level. The amount ofallowable va
12、riation is specified by others such as a consultant,designer, or owner.1This test method is under the jurisdiction ofASTM Committee E33 on Buildingand Environmental Acoustics and is the direct responsibility of SubcommitteeE33.02 on Open Plan Spaces.Current edition approved April 1, 2009. Published
13、April 2009. Originallyapproved in 1993. Last previous edition approved in 2002 as E 157302.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Su
14、mmary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.4 temporal uniformityat
15、a given position, a conditionwhere the average sound pressure level measured over a shorttime interval does not differ significantly from the averagesound pressure level measured over a long time interval. Theamount of allowable variation is specified by others such as aconsultant, designer, or owne
16、r.4. Summary of Test Method4.1 The spatial uniformity of the masking sound in an openoffice is determined by measuring the A-weighted averagesound level with a sound level meter or real time analyzer atseveral locations and comparing these values to the arithmeticmean sound level or to a specified l
17、evel. The temporaluniformity of the masking sound is determined by measuringtheA-weighted sound levels over an extended period of time atone or more locations. The masking sound spectrum and levelis determined by measuring the one-third octave band soundpressure levels at one or more locations.5. Si
18、gnificance and Use5.1 Speech privacy in an open office is dependent on manyfactors (see Guide E 1374 for a discussion on open officeacoustical considerations). One of these factors is the maskingsound in the office. Without masking sound in the open office,confidential speech privacy is not possible
19、 at normal voicelevels. The four critical acoustical parameters of maskingsound are its spatial uniformity, temporal uniformity, spectrumshape, and level. The measurement and determination of theseparameters are addressed in this test method.5.2 The results from this test method can be used todeterm
20、ine if the masking sound meets a particular specifica-tion.6. Test Space6.1 The test space shall include the entire office area servedby the masking system, or as otherwise specified.6.2 The ceiling system of the test space shall be completelyfinished, including light fixtures and air diffusers.6.3
21、The floor covering and all wall finishes shall be com-pletely installed prior to testing.6.4 To provide the most meaningful information concerningthe ability of the masking sound to provide consistent privacy,it is preferable to test with interior furnishings in place sincefurniture may influence th
22、e distribution of masking soundwithin the space. However, this test method may also be usedfor unfurnished spaces.6.5 The office space shall be unoccupied during the tests.7. Test Signal7.1 The test signal used for this evaluation may be any ofthe following:7.1.1 The sound due to the HVAC system, th
23、e maskingsound system, and any other noise sources,7.1.2 The sound due to the masking sound system alone, or7.1.3 The sound due to the HVAC system alone.7.2 If the intent is to evaluate the performance of thecombination of sounds from the masking sound system, soundsources associated with the HVAC s
24、ystem and other equip-ment, then the test procedures shall be carried out with themasking sound system adjusted as intended to be used in theoccupied space. The HVAC system should be operated at itsnoisiest and quietest settings or conditions.7.3 If the intent is to evaluate the performance of thema
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便