ASTM E1432-2004 Standard Practice for Defining and Calculating Individual and Group Sensory Thresholds from Forced-Choice Data Sets of Intermediate Size《中型的规定数据集的个体和群体感观阈值的确定和计算的标准.pdf
《ASTM E1432-2004 Standard Practice for Defining and Calculating Individual and Group Sensory Thresholds from Forced-Choice Data Sets of Intermediate Size《中型的规定数据集的个体和群体感观阈值的确定和计算的标准.pdf》由会员分享,可在线阅读,更多相关《ASTM E1432-2004 Standard Practice for Defining and Calculating Individual and Group Sensory Thresholds from Forced-Choice Data Sets of Intermediate Size《中型的规定数据集的个体和群体感观阈值的确定和计算的标准.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1432 04Standard Practice forDefining and Calculating Individual and Group SensoryThresholds from Forced-Choice Data Sets ofIntermediate Size1This standard is issued under the fixed designation E 1432; the number immediately following the designation indicates the year oforiginal adopt
2、ion or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONThe purpose of this practice is to determine individual sensory threshol
3、ds for odor, taste, and othermodalities and, when appropriate, calculate group thresholds. The practice takes as its starting pointany sensory threshold data set of more than 100 presentations, collected by a forced-choice procedure.The usual procedure is the Three-Alternative Forced-Choice (3-AFC),
4、 as exemplified by DynamicTriangle Olfactometry. A similar practice, Practice E 679, utilizes limited-size data sets of 50 to 1003-AFC presentations, and is suitable as a rapid method to approximate group thresholds.Collection of the data is not a part of this practice. The data are assumed to be va
5、lid; for example,it is assumed that the stimulus is defined properly, that each subject has been fully trained to recognizethe stimulus and did indeed perceive it when it was present above his or her momentary threshold, andthat the quality of dilution medium did not vary.It is recognized that preci
6、se threshold values for a given substance do not exist in the same sensethat values of vapor pressure exist. A panelists ability to detect a stimulus varies as a result of randomvariations in factors such as alertness, attention, fatigue, events at the molecular level, health status,etc., the effect
7、s of which can usually be described in terms of a probability function. At lowconcentrations of an odorant or tastant, the probability of detection by a given individual is typically0.0 and at high concentrations it is 1.0, and there is a range of concentrations in which the probabilityof detection
8、is between these limits. By definition, the threshold is the concentration for which theprobability of detection of the stimulus is 0.5 (that is, 50 % above chance, by a given individual, underthe conditions of the test).Thresholds may be determined (1) for an individual (or for individuals one by o
9、ne), and (2) for agroup (panel). While the determination of an individual threshold is a definable task, carefulconsideration of the composition of the group is necessary to ensure the determined thresholdrepresents the group of interest.There is a large degree of random error associated with estima
10、ting the probability of detection fromless than approximately 500 3-AFC presentations. The reliability of the results can be increasedgreatly by enlarging the panel and by replicating the tests.1. Scope1.1 The definitions and procedures of this practice apply tothe calculation of individual threshol
11、ds for any stimulus in anymedium, from data sets of intermediate size, that is, consistingof more than 20 to 40 3-AFC presentations per individual. Agroup threshold may be calculated using 5 to 15 individualthresholds.1.2 This standard does not purport to address all of thesafety concerns, if any, a
12、ssociated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1This practice is under the jurisdiction of ASTM Committee E18 on SensoryEvaluation of Materials
13、and Products and is the direct responsibility of Subcom-mittee E18.04 on Fundamentals of Sensory.Current edition approved April 1, 2004. Published April 2004. Originallyapproved in 1991. Last previous edition approved in 1997 as E 143291 (1997).1Copyright ASTM International, 100 Barr Harbor Drive, P
14、O Box C700, West Conshohocken, PA 19428-2959, United States.2. Principles2.1 The 3-AFC procedure is one of the set of n-AFCprocedures, any of which could be used, in principle, for themeasurement of sensory thresholds, as could the duo-trio, thetriangular, and the two-out-of-five procedures.2.2 For
15、calculation of the threshold of one individual, thispractice requires data sets taken at five or more concentrationscale steps, typically six or seven steps, with each step differingfrom the previous step by a factor usually between 2 and 4,typically 3.0. The practice presupposes that the range ofco
16、ncentrations has been selected by pretesting, in order toensure that the individuals threshold falls neither outside nornear the ends of the range, but well within it. At eachconcentration step, the individual must be tested several times,typically five or more times.2.3 Individual thresholds, as de
17、termined in 2.2, may be usedfor calculation of a group (or panel) threshold. The size andcomposition of the panel (usually 5 to 15 members, preferablymore) is determined according to the purpose for which thethreshold is required and the limitations of the testing situation(see 7.2).2.4 Pooling of t
18、he data sets from panel members to producea single step calculation of the panel threshold is not permitted.3. Referenced Documents3.1 ASTM Standards:2E 122 Practice for Calculating Sample Size to Estimate,With a Specified Tolerable Error, the Average for Charac-teristic of a Lot or ProcessE 679 Pra
19、ctice for Determination of Odor and Taste Thresh-olds By a Forced-Choice Ascending Concentration SeriesMethod of Limits3.2 CEN Standard:3EN 13725 Air QualityDetermination of Odour Concen-tration Using Dynamic Dilution Olfactometry3.3 ISO Standard:4ISO 13301 Sensory AnalysisMethodologyGeneralguidance
20、 for Measuring Odour, Flavour, and Taste Detec-tion Thresholds by a Three Alternative Forced Choice(3-AFC) Procedure4. Terminology4.1 Definitions of Terms Specific to This Standard:4.1.1 Three-Alternative Forced-Choice (3-AFC) testprocedurea test presentation used in many threshold tests.For example
21、, in odor testing by Dynamic Triangle Olfactom-etry, the panelist is presented with three gas streams, only oneof which contains the diluted odorant, while the other twocontain odorless carrier gas. The panelist must indicate the onecontaining the added substance. (The 3-AFC procedure isdifferent fr
22、om the classical Triangle test, in which either one ortwo of the three samples may contain the added substance.)4.1.2 modelan abstract or concrete analogy, usually math-ematical, which represents in a useful way the functionalelements of a system or process. In short, the experimenterstheory of what
23、 is guiding the results observed.4.1.3 statistical modela model assuming that the principalfactor causing the results to deviate from the true value is arandom error process. This can usually be described in terms ofa probability function, for example, a bell-shaped curve,symmetrical or skewed. Erro
24、rs are binomially distributed in the3-AFC test procedure.4.1.4 threshold, detectionthe intensity of the stimulus thathas a probability of 0.5 of being detected under the conditionsof the test. The probability of detection at any intensity is nota fixed attribute of the observer, but rather a value w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME14322004STANDARDPRACTICEFORDEFININGANDCALCULATINGINDIVIDUALANDGROUPSENSORYTHRESHOLDSFROMFORCEDCHOICEDATASETSOFINTERMEDIATESIZE

链接地址:http://www.mydoc123.com/p-528682.html