《ASTM E1199-1987(2012) Standard Practice for Sampling Zooplankton with a Clarke-Bumpus Plankton Sampler《用克-朋氏浮游生物采样器采集浮游生物的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1199-1987(2012) Standard Practice for Sampling Zooplankton with a Clarke-Bumpus Plankton Sampler《用克-朋氏浮游生物采样器采集浮游生物的标准实施规程》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1199 87 (Reapproved 2012)Standard Practice forSampling Zooplankton with a Clarke-Bumpus PlanktonSampler1This standard is issued under the fixed designation E1199; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the procedures for obtaining quan-titative samples of a zooplankton community by use of aCl
3、arke-Bumpus plankton sampler.1.2 This standard does not purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations
4、 prior to use.2. Referenced Documents2.1 ASTM Standards:2D4134 Practice for Sampling Phytoplankton with a Clarke-Bumpus Plankton SamplerE1200 Practice for Preserving Zooplankton Samples3. Summary of Practice3.1 The sampler is towed from a moving boat at a specifieddepth. The sampler uses a net for t
5、he collection and concen-tration of zooplankton. The actual volume of water entering thesampler is measured by a calibrated flowmeter. The zooplank-ton are preserved as dictated by the objectives of the study.4. Significance and Use4.1 The advantages of the Clarke-Bumpus plankton samplerare as follo
6、ws:4.1.1 It will sample a discrete depth or multiple depths,depending upon the sampling design.4.1.2 It is a slow to medium speed sampler requiring atowing speed of three to five knots.4.1.3 The sample size can be easily controlled.4.1.4 The sampler is lightweight and can be used withoutauxiliary eq
7、uipment.4.1.5 It has a relatively high filtration efficiency factor of0.88.4.1.6 It is a versatile sampler and can be used in all but theshallowest waters.4.1.7 The flowmeter records the amount of water that passesinto the net.4.1.8 Overspill of water at the mouth of the net due toexcess speed of to
8、wing is of minimal consequence.4.2 The disadvantages of the Clarke-Bumpus plankton sam-pler are as follows:4.2.1 The flowmeter requires frequent maintenance includ-ing calibration and lubrication.4.2.2 It is not suitable for use in very small areas or shallowwaters.4.3 There are several special cons
9、iderations that shall beobserved when using a Clarke-Bumpus sampler. They are:4.3.1 The flowmeter should be calibrated and servicedfrequently to ensure efficient and accurate operation.4.3.2 The sampler is relatively fragile, particularly theclosing device and flowmeter. This necessitates careful de
10、ploy-ment and recovery procedures.4.3.3 Following each collection, the net must be thoroughlywashed.4.3.4 Special attention must be given to the strength of thecable and its attachment to avoid loss of the sampler.4.3.5 The sampler should not be used in beds ofmacrophytes, in waters containing subme
11、rged objects, or closeto the bottom.4.3.6 The net should be inspected frequently for pin-sizeholes, tears, net deterioration, and other anomalies.4.3.7 Following use, the wet net should be suspended fulllength in the air in subdued light and allowed to dry.5. Apparatus5.1 The Clarke-Bumpus zooplankt
12、on sampler is a 5-in.diameter by 6-in. long brass tube consisting of a metal frame inwhich an interchangeable conical plankton net is attached at1This practice is under the jurisdiction of ASTM Committee E47 on BiologicalEffects and Environmental Fate and is the direct responsibility of Subcommittee
13、E47.01 on Aquatic Assessment and Toxicology.Current edition approved Dec. 1, 2012. Published December 2012. Originallyapproved in 1987. Last previous edition approved in 2004 as E1199 87 (2004).DOI: 10.1520/E1199-87R12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact A
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME119919872012STANDARDPRACTICEFORSAMPLINGZOOPLANKTONWITHACLARKEBUMPUSPLANKTONSAMPLER 用克朋氏 浮游生物 采样

链接地址:http://www.mydoc123.com/p-528150.html