ASTM E1158-2004 Standard Guide for Material Selection and Fabrication of Reference Blocks for the Pulsed Longitudinal Wave Ultrasonic Examination of Metal and Metal Alloy Productio.pdf
《ASTM E1158-2004 Standard Guide for Material Selection and Fabrication of Reference Blocks for the Pulsed Longitudinal Wave Ultrasonic Examination of Metal and Metal Alloy Productio.pdf》由会员分享,可在线阅读,更多相关《ASTM E1158-2004 Standard Guide for Material Selection and Fabrication of Reference Blocks for the Pulsed Longitudinal Wave Ultrasonic Examination of Metal and Metal Alloy Productio.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1158 04Standard Guide forMaterial Selection and Fabrication of Reference Blocks forthe Pulsed Longitudinal Wave Ultrasonic Examination ofMetal and Metal Alloy Production Material1This standard is issued under the fixed designation E 1158; the number immediately following the designati
2、on indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers general procedur
3、es for the materialselection and fabrication of reference blocks made of metal ormetal alloys and intended to be used for the examination of thesame or similar production materials by pulsed longitudinalultrasonic waves applied perpendicular to the beam entrysurface. Primary emphasis is on solid mat
4、erials but some of thetechniques described may be used for midwall examination ofpipes and tubes of heavy wall thickness. Near-surface resolu-tion in any material depends upon the characteristics of theinstrument and search unit employed.1.2 This guide covers the fabrication of reference blocks foru
5、se with either the immersion or the direct-contact method ofultrasonic examination.1.3 Reference blocks fabricated in accordance with thisguide can be used to determine proper ultrasonic examinationsystem operation. Area-amplitude and distance-amplitudecurves can also be determined with these refere
6、nce blocks.1.4 This guide does not specify reference reflector sizes orproduct rejection limits. It does describe typical industryfabrication practices and commonly applied tolerances wherethey lend clarity to the guide. In all cases of conflict betweenthis guide and customer specifications, the cus
7、tomer specifica-tion shall prevail.1.5 This standard does not purport to address the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealth practices and to determine the applicability of regula-tory limitations
8、 prior to use.2. Referenced Documents2.1 ASTM Standards:2E 127 Practice for Fabricating and Checking AluminumAlloy Ultrasonic Standard Reference Blocks3E 428 Practice for Fabrication and Control of Steel Refer-ence Blocks Used in Ultrasonic ExaminationE 1316 Terminology for Nondestructive Examinatio
9、ns3. Terminology3.1 DefinitionsFor definitions of terms used in this guide,see Terminology E 1316.4. Summary of Guide4.1 This guide describes a method of selecting suitablereference block material from current or previous productionand the subsequent fabrication and checking of the resultingultrason
10、ic reference blocks.5. Significance and Use5.1 This guide is intended to illustrate the fabrication ofultrasonic reference blocks that are representative of theproduction material to be examined. Care in material selectionand fabrication can result in the manufacture of referenceblocks that are ultr
11、asonically similar to the production materialthus eliminating the reference block as an examination vari-able.6. Material Selection6.1 It is good practice to use a sample removed from theproduction lot of material as the reference block material.When this is not possible the following guidelines sho
12、uld befollowed.6.2 The reference block material should be of the samegeneral shape and dimensions, surface finish, chemical com-position, and microstructure as the production material to beexamined.6.3 To ensure that the material chosen is suitable for use asreference block material and is free of p
13、otentially interfering1This guide is under the jurisdiction of ASTM Committee E07 on Nondestruc-tive Testing and is the direct responsibility of Subcommittee E07.06 on UltrasonicMethod.Current edition approved February 1, 2004. Published March 2004. Originallyapproved in 1990. Last previous edition
14、approved in 1998 as E 1158 - 98.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The reference blocks in Prac
15、tice E 127 are used to check the performance ofultrasonic examination equipment and for standardization and control of ultrasonicexaminations of aluminum alloy products. The ultrasonic response of the blocks inPractice E 127 is evaluated against a standard target. The blocks described in thisstandar
16、d are used for the examination of production material and may be used toestablish accept-reject criteria.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.reflectors, ultrasonically examine the reference block materialat the anticipate
17、d examining frequency and at a sensitivity thatproduces an acoustic noise level of 20 % screen height. Theentire block should be scanned from the surface which will beused for standardization. Any discrete indication that exceeds40 % screen height should be cause to remove the materialfrom considera
18、tion as an ultrasonic reference block.6.4 Reference block material that meets the guidelines of6.3 should then be examined at a sensitivity that producesmultiple reflections from the back surface (between 3 and 5reflections in most metals and metal alloys). The productionmaterial should be examined
19、at the same sensitivity level todetermine that the same number of back reflections areobtained. This procedure may have to be repeated several timesand an average number of back reflections determined in thecase of some materials (see Note 1).NOTE 1In some highly attenuative materials more than one
20、or twoback reflections may not be attainable. In these cases, selection of thereference block material may be based on similar acoustic noise levelsfrom both the production material and that chosen for a reference block.7. Reference Block Configuration7.1 There are many different types of reference
21、blocks usedin industry depending upon the size and shape of the materialto be examined. Some of the more common types are describedin 7.2 through 7.7, and shown in Figs. 1-7. An alternate methodfor fabricating flat-bottom holes is described in the annex.7.2 Fig. 1 shows the typical reference standar
22、ds used forultrasonic examination when the product to be examinedconsists of large round bar stock, between 1 and 10 in. indiameter. With such products it is often necessary to correct forthe loss of signal with increasing examination distance(distance-amplitude-correction, or DAC). Therefore, a ste
23、ppedblock, as shown in Fig. 1 is commonly used. This type of blockis typically referred to as a distance-amplitude-block. It con-tains a number of holes of the same size at various distancesfrom the scan surface. A typical flat-bottom hole size found inmany such blocks is564 in. or larger depending
24、upon theultrasonic attenuation, or the internal structure of the product,or both. For even larger diameter bars the distance amplitudecorrection reference standard may contain even larger flatbottom holes, possibly14 in. or greater.7.3 To determine the linearity of the examination and toestablish th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME11582004STANDARDGUIDEFORMATERIALSELECTIONANDFABRICATIONOFREFERENCEBLOCKSFORTHEPULSEDLONGITUDINALWAVEULTRASONICEXAMINATIONOFMETALANDMETALALLOYPRODUCTIOPDF

链接地址:http://www.mydoc123.com/p-528037.html