ASTM E1064-2005 Standard Test Method for Water in Organic Liquids by Coulometric Karl Fischer Titration《由库仑计卡耳 费歇尔滴定法测定有机液体中水的标准试验方法》.pdf
《ASTM E1064-2005 Standard Test Method for Water in Organic Liquids by Coulometric Karl Fischer Titration《由库仑计卡耳 费歇尔滴定法测定有机液体中水的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1064-2005 Standard Test Method for Water in Organic Liquids by Coulometric Karl Fischer Titration《由库仑计卡耳 费歇尔滴定法测定有机液体中水的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1064 05Standard Test Method forWater in Organic Liquids by Coulometric Karl FischerTitration1This standard is issued under the fixed designation E 1064; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of las
2、t revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers the determinati
3、on of water from0 to 2.0 % mass in most liquid organic chemicals, with KarlFischer reagent, using an automated coulometric titrationprocedure. Use of this test method is not applicable forliquefied gas products such as Liquid Petroleum Gas (LPG),Butane, Propane, Liquid Natural Gas (LNG), etc.1.2 The
4、 values stated in SI units are to be regarded as thestandard.1.3 Review the current material safety data sheets (MSDS)for detailed information concerning toxicity, first-aid proce-dures, handling, and safety precautions.1.4 This standard does not purport to address all of thesafety problems, if any,
5、 associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary statements are given in Section 8.2. Referenced Documents2.1 ASTM Stan
6、dards:2D 1193 Specifications for Reagent WaterD 4672 Test Methods for Polyurethane Raw Materials:Determination of Water Content of PolyolsE 180 Practice for Determining the Precision of ASTMMethods for Analysis and Testing of Industrial and Spe-cialty ChemicalsE 203 Test Method for Water Using Volum
7、etric Karl FischerTitration3. Summary of Test Method3.1 This test method is based on the Karl Fischer reactionfor determining waterthe reduction of iodine by sulfurdioxide in the presence of water to form sulfur trioxide andhydriodic acid. The reaction becomes quantitative only whenpyridine or other
8、 organic base and methanol or other alcoholare present. Unlike the volumetric Karl Fischer reagents thatinclude iodine, the coulometric technique electrolytically gen-erates iodine, with 10.71 C of generating current correspondingto 1 mg of water in accordance with Faradays law.4. Significance and U
9、se4.1 The coulometric technique is especially suited for de-termining low concentrations of water in organic liquids thatwould yield small titers by the Karl Fischer volumetricprocedure. The precision and accuracy of the coulometrictechnique decreases for concentrations of water much greaterthan 2.0
10、 % because of the difficulty in measuring the small sizeof sample required. The test method assumes 100 % efficiencyof coulombs in iodine production. Provision is made forverifying this efficiency. (See Table 1 and Note 6.)1This test method is under the jurisdiction of ASTM Committee E15 onIndustria
11、l and Specialty Chemicals and is the direct responsibility of SubcommitteeE15.01 on General Standards.Current edition approved Oct. 1, 2005. Published November 2005. Originallyapproved in 1985. Last previous edition approved in 2004 as E 1064 04a.2For referenced ASTM standards, visit the ASTM websit
12、e, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States
13、.5. Interferences5.1 Interfering substances are the same as are encounteredin the volumetric Karl Fischer titration. A detailed discussionof interfering substances can be found in the treatise on“Aquametry.”35.2 Test Method E 203 discusses organic compounds inwhich water may be determined directly a
14、nd compounds inwhich water cannot be determined directly, but in whichinterferences may be eliminated by suitable chemical reactions.6. Apparatus6.1 Automatic Titrator,4consisting of a control unit, titrationvessel, dual platinum sensing electrode, generator assembly,and magnetic stirrer. The instru
15、ment is designed to coulometri-cally generate iodine that reacts stoichiometrically with thewater present in the sample solution. The coulombs of elec-tricity required to generate the reagent are converted tomicrograms of water, which is obtained as a direct digitalreadout.6.2 Syringe, 50-mL, fitted
16、 with an 115-mm hypodermicneedle for removing excess solution from the titration chamber.NOTE 1Rinse all glass syringes and needles with anhydrous acetoneafter cleaning, then dry in an oven at 100C for at least 1 h and store ina desiccator. Plastic syringes shall be disposed of following use.6.3 Syr
17、inge, 20-mL, fitted with an 115-mm hypodermicneedle for introduction of neutralizing solution into the titrationchamber (see Note 1).6.4 Syringes, 1- and 5-mL, fitted with 115-mm hypodermicneedles for introduction of samples into titration chamber (seeNote 1).6.5 Syringe, 5 L, fitted with 115-mm hyp
18、odermic needlefor standardization of instrument (see Note 1).6.6 Fluorocarbon Sealing Grease or TFE-Fluorocarbon,toseal the titration chamber against atmospheric moisture.6.7 Septa, to seal sample port but allow introduction ofsamples by a needle with a minimum of moisture contamina-tion. Replace se
19、rum caps and septa as required to prevent airleakage as indicated by instrument drift.6.8 Serum Bottles.6.9 Oven, temperature 100 6 5C.6.10 Dessicator, standard laboratory type with color changeindicator.6.11 Analytical Balance, capable of weighing to 60.0001 g.7. Reagents7.1 Purity of ReagentsUnles
20、s otherwise indicated, it isintended that all reagents shall conform to the specifications ofthe Committee onAnalytical Reagents of theAmerican Chemi-cal Society, where such specifications are available.5Othergrades may be used, provided it is first ascertained that thereagent is of sufficiently hig
21、h purity to permit its use withoutlessening the accuracy of the determination.7.2 Purity of WaterUnless otherwise indicated, referenceto water shall be understood to mean Type II or Type IIIreagent water, conforming to Specification D 1193.7.3 Karl Fischer ReagentsCommercial coulometric KFreagents a
22、nd reagent systems of various types are available foruse with autotitrators for water determination. Traditionally,pyridine was the organic base used in KF reagents. Pyridine-free formulations are available and are preferred by most KFinstrument manufacturers for use with their equipment. Thepyridin
23、e-free reagents are less toxic, less odorous, and morestable than those containing pyridine. The use of pyridine-freereagents is recommended whenever possible. Coulometrictitrations normally require two reagent solutions.An anolyte orsolvent titration solution and a catholyte or generator titrantsol
24、ution. However, now reagents can be purchased in one ortwo component reagent systems. A one component reagentsystem contains all the components required for a Karl Fischertitration in a single solution. A two component system incor-porates separate solutions for the solvent and titrant.NOTE 2Two goo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME10642005STANDARDTESTMETHODFORWATERINORGANICLIQUIDSBYCOULOMETRICKARLFISCHERTITRATION 库仑计 卡耳费歇尔 滴定法

链接地址:http://www.mydoc123.com/p-527838.html