ASTM E1061-2001(2014) 0979 Standard Specification for Direct-Reading Liquid Crystal Forehead Thermometers《直读式带液晶头温度计的标准规格》.pdf
《ASTM E1061-2001(2014) 0979 Standard Specification for Direct-Reading Liquid Crystal Forehead Thermometers《直读式带液晶头温度计的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1061-2001(2014) 0979 Standard Specification for Direct-Reading Liquid Crystal Forehead Thermometers《直读式带液晶头温度计的标准规格》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1061 01 (Reapproved 2014)Standard Specification forDirect-Reading Liquid Crystal Forehead Thermometers1This standard is issued under the fixed designation E1061; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers direct-reading liquid crystalforehead thermometers designed to monitor trends or measur
3、ehuman forehead surface temperatures, or both.1.2 Thermometers covered by this specification are gener-ally available in continuous or intermittent reading modes.Thermometers meeting the requirements specified herein shallbe considered as complying with this specification.1.3 The following precautio
4、nary caveat pertains only to thetest method portion, Section 5, of this specification.Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to consult and establish appropriate safety andhealth practi
5、ces and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E344 Terminology Relating to Thermometry and Hydrom-etry3. Terminology3.1 DefinitionsFor definitions of terms used in thisspecification, refer to Terminology E344.3.2 Definitions of T
6、erms Specific to This Standard:3.2.1 center green (CG) or mid green (MG), nthat tem-perature which unifies the visual and instrumental evaluationmethods and is defined by the equation:CG 5 MG 5SG1SB25 T520See 3.2.5.2 for description of T520.3.2.2 color play, nthe predictable sequence of colorsexhibi
7、ted by a liquid crystal formulation as it passes through itsactive temperature range. For example, as temperatureincreases, a formulation exhibits successive tan, red, green, andblue colors.3.2.3 manufacturing lot, n(1) in the case of continuousmanufacturing processes, a lot is a specifically identi
8、fiedamount produced in a unit of time or quantity in a manner thatassumes its having uniform characteristics and quality withinspecified limits.(2) In the case of batch processes, a lot means a batch orspecifically identified portion of a batch assumed to haveuniform characteristics and quality with
9、in specified limits.3.2.4 sequencing, na characteristic whereby the thermalprofiles of the liquid crystal formulations of a given thermom-eter follow each other in an orderly predetermined manner.3.2.5 specific color phenomena, n (using instrumental meth-ods of evaluation):3.2.5.1 bluethat temperatu
10、re at which the intensity of 470nm light reflected by the liquid crystal is maximum, symbol-ized as T470.3.2.5.2 greenthat temperature at which the intensity of520 nm light reflected by the liquid crystal is maximum,symbolized as T520.3.2.5.3 redthat temperature at which the intensity of 650nm light
11、 reflected by the liquid crystal is maximum, symbol-ized as T650.3.2.6 start of blue (SB), nthat temperature at which theliquid crystal first begins to reflect blue light, which is definedas light having a wavelength of 491 nm.3.2.7 start of green (SG), nthat temperature at which theliquid crystal f
12、irst begins to reflect green light, which is definedas light having a wavelength of 575 nm.3.2.8 start of red (SR), nthat temperature at which theliquid crystal first begins to reflect red light, which is defined aslight having a wavelength of 675 nm.3.2.9 thermal profile, ntemperatures at which spe
13、cificcolor phenomena occur in a liquid crystal thermometer.3.2.10 visible start (VS), nthat temperature at which theliquid crystal first begins to reflect visible light.1This specification is under the jurisdiction of ASTM Committee F04 onMedical and Surgical Materials and Devices and is the direct
14、responsibility ofSubcommittee F04.33 on Medical/Surgical Instruments.Current edition approved Oct. 1, 2014. Published November 2014. Originallyapproved in 1985. Last previous edition approved in 2007 as E1061 01(2007).DOI: 10.1520/E1061-01R14.2For referenced ASTM standards, visit the ASTM website, w
15、ww.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14. R
16、equirements4.1 GeneralThermometers represented as complying withthis specification shall meet all of the requirements specifiedherein.4.2 Temperature RangeThe liquid crystal forehead ther-mometer shall, as a minimum, meet all requirements of thisspecification over the temperature range of 32.0 to 38
17、.0 C (90to 100 F). Some color must remain visible up to temperaturesof 39.5 C (103 F).4.3 ToleranceWhenever a temperature for a specific colorphenomenon (3.2.1) is measured, the maximum permissibledeviation is 60.6 C (61.0 F), when tested according to 5.2of this standard.4.4 SequencingThermal profil
18、es of the liquid crystal for-mulations must be such that: (1) no two readouts are the samecolor within the temperature range of red start to blue start atthe same time; and (2) within the temperature range of thedevice, color must be visible in at least one graphical repre-sentation at all times.4.5
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME1061200120140979STANDARDSPECIFICATIONFORDIRECTREADINGLIQUIDCRYSTALFOREHEADTHERMOMETERS 直读 液晶 温度计

链接地址:http://www.mydoc123.com/p-527837.html