ASTM E1007-2011 6875 Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures《通过天棚.pdf
《ASTM E1007-2011 6875 Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures《通过天棚.pdf》由会员分享,可在线阅读,更多相关《ASTM E1007-2011 6875 Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures《通过天棚.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1007 11Standard Test Method forField Measurement of Tapping Machine Impact SoundTransmission Through Floor-Ceiling Assemblies andAssociated Support Structures1This standard is issued under the fixed designation E1007; the number immediately following the designation indicates the year
2、oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis test method is part of a set of standards for evalua
3、ting the sound insulating properties ofbuilding elements and sound isolation between spaces. It is designed to measure in the field the impactsound isolation between rooms or to estimate lower limits for impact sound transmission through afloor-ceiling partition element installed as an interior part
4、 of a building using a standard tappingmachine. Others in the set cover measurement of impact sound transmission through an isolatedfloor-ceiling assembly in a controlled laboratory environment (Test Method E492), the measurementof airborne sound transmission loss of an isolated partition element in
5、 a controlled laboratoryenvironment (Test Method E90), the measurement of airborne sound isolation and airborne soundtransmission loss associated with building elements in the field (Test Method E336), the measurementof sound transmission through building facades and facade elements in the field (Gu
6、ide E966); and themeasurement of sound transmission through a common plenum between two rooms in a controlledlaboratory environment (Test Method E1414).1. Scope1.1 This test method covers the measurement of the trans-mission of impact sound generated by a standard tappingmachine through floor-ceilin
7、g assemblies and associated sup-porting structures in field situations.1.2 Measurements may be conducted on all types of floor-ceiling assemblies, including those with floating-floor or sus-pended ceiling elements, or both, and floor-ceiling assembliessurfaced with any type of floor-surfacing or flo
8、or-coveringmaterials.1.3 This test method defines several procedures and metricsto assess either the apparent performance of the nominallyseparating floor-ceiling or the isolation of a receiving roomfrom the sound produced by the operation of the tappingmachine. The receiving room may be the space d
9、irectly belowthe tapping machine or, in some cases, any separated space thatreceives sound from the operation of the tapping machine. Thesource and receiving rooms as well as the floor-ceiling systemare identified and described in the test report. All measuredlevels and derivative single number rati
10、ngs include the effect offlanking transmission. Efforts to suppress flanking are notpermitted. Available measures and their single number ratingsare the impact sound pressure levels (ISPL) and impact soundrating (ISR), the reverberation time normalized impact soundpressure levels (RTNISPL) and norma
11、lized impact soundrating (NISR), and the absorption normalized impact soundpressure levels (ANISPL) and apparent impact insulation class(AIIC).1.4 The text of this standard references notes and footnoteswhich provide explanatory material. These notes and footnotes(excluding those in tables and figur
12、es) shall not be consideredas requirements of the standard.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1This test method is under the jurisdiction ofASTM Committee E33 on Buildingand Environmental Acoustics and is the di
13、rect responsibility of SubcommitteeE33.03 on Sound Transmission.Current edition approved March 1, 2011. Published March 2011. Originallyapproved 1984. Last previous edition approved in 2004 as E1007 041. DOI:10.1520/E1007-11.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Con
14、shohocken, PA 19428-2959, United States.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory
15、limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C634 Terminology Relating to Building and EnvironmentalAcousticsE90 Test Method for Laboratory Measurement of AirborneSound Transmission Loss of Building Partitions and Ele-mentsE336 Test Method for Measurement of Airborne SoundAtte
16、nuation between Rooms in BuildingsE492 Test Method for Laboratory Measurement of ImpactSound Transmission Through Floor-Ceiling AssembliesUsing the Tapping MachineE966 Guide for Field Measurements of Airborne SoundAttenuation of Building Facades and Facade ElementsE989 Classification for Determinati
17、on of Impact InsulationClass (IIC)E1414 Test Method for Airborne Sound Attenuation Be-tween Rooms Sharing a Common Ceiling PlenumE2235 Test Method for Determination of Decay Rates forUse in Sound Insulation Test Methods2.2 ANSI Standards:3S1.11 Specification for Octave Band and Fractional-Octave-Ban
18、d Analog and Digital FiltersS1.40 Specifications and Verification Procedures for SoundCalibratorsS1.43 Specifications for Integrating-Averaging Sound LevelMeters2.3 ISO Standard:4ISO 140AcousticsMeasurement of Sound Insulation inBuildings and of Building Elements; Part VILaboratoryMeasurement of Imp
19、act Sound Insulation of Floors, andPart VIIField Measurements of Impact Sound Insula-tion of Floors2.4 IEC Standards5:IEC 60942 Electroacoustics Sound CalibratorsIEC 616721 Electroacoustics - Sound Level Meters Part1:Specifications3. Terminology3.1 DefinitionsFor definitions of terms pertaining toac
20、oustics used in this test method, see Terminology C634.3.2 Definitions of Terms Specific to This Standard:3.2.1 absorption normalized impact sound pressure level,ANISPL, (dB), ninto a receiving room of at least 40 m3in aspecified frequency band, the impact sound pressure level(ISPL) normalized to a
21、reference absorption of 10 m2in thereceiving room.3.2.1.1 Discussion10 m2is equivalent to 108 Sabins3.2.2 apparent impact insulation class, AIIC, na single-number rating derived from values of ANISPL in accordancewith Classification E989.3.2.2.1 Discussionfield impact insulation class (FIIC) hasbeen
22、 replaced with apparent impact insulation class (AIIC) tomake clear that the quantity includes flanking and to harmonizeterminology with Test Method E336.3.2.2.2 DiscussionAIIC provides an estimate of the ap-parent sound insulating properties of a floor-ceiling assemblyunder tapping machine excitati
23、on where sound power fromassociated support structures are attributed to the floor-ceilingassembly.3.2.2.3 DiscussionThe absorption normalized impactsound pressure level (ANISPL) and apparent impact insulationclass (AIIC) are analogous to apparent transmission loss (ATL)and apparent sound transmissi
24、on class (ASTC) for airbornemeasurements.3.2.3 coupled space, na secondary space large enough topermit measurements without microphones too close to sur-faces, but separated from the receiving room (which is partiallybounded by the separating floor-ceiling) by a partial barrierwith an opening that i
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME100720116875STANDARDTESTMETHODFORFIELDMEASUREMENTOFTAPPINGMACHINEIMPACTSOUNDTRANSMISSIONTHROUGHFLOORCEILINGASSEMBLIESANDASSOCIATEDSUPPORTSTRUCTURES

链接地址:http://www.mydoc123.com/p-527723.html