ASTM E1007-2004e1 Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures《通过地板和天花.pdf
《ASTM E1007-2004e1 Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures《通过地板和天花.pdf》由会员分享,可在线阅读,更多相关《ASTM E1007-2004e1 Standard Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures《通过地板和天花.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1007 04e1Standard Test Method forField Measurement of Tapping Machine Impact SoundTransmission Through Floor-Ceiling Assemblies andAssociated Support Structures1This standard is issued under the fixed designation E 1007; the number immediately following the designation indicates the y
2、ear oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEEquations 2 and 3 were editorially corrected in July 2004.
3、INTRODUCTIONThis test method is part of a set of standards for evaluating the sound insulating properties ofbuilding elements. It is designed to measure the impact sound insulation of a floor-ceiling assemblyand associated supporting structures in field situations using a standard tapping machine. O
4、ther in theset cover laboratory measurement of impact sound transmission through floor-ceiling assemblies (TestMethod E 492); and the laboratory (Test Method E 90) and field (Test Method E 336) methods ofmeasuring airborne sound transmission loss of building partitions such as walls, floor-ceilingas
5、semblies, doors, and other space-dividing elements; the measurement of sound transmission throughbuilding facades and facade elements (Guide E 966); the measurement of sound transmission througha common plenum between two rooms (Test Method E 1414), a quick method for the determinationof airborne so
6、und isolation in multiunit buildings (Practice E 597), and the measurement of soundtransmission through door panels and systems (Test Method E 1408).1. Scope1.1 This test method covers the measurement of the trans-mission of impact sound generated by a standard tappingmachine through floor-ceiling a
7、ssemblies and associated sup-porting structures in field situations.1.2 Measurements may be conducted on all types of floor-ceiling assemblies, including those with floating-floor or sus-pended ceiling elements, or both, and floor-ceiling assembliessurfaced with any type of floor-surfacing or floor-
8、coveringmaterials.1.3 This test method further prescribes:1.3.1 A uniform procedure for reporting test data, that is, thenormalized one-third octave band sound pressure levels gen-erated in the receiving room by the operation of the standardtapping machine on the floor-ceiling assembly.1.3.2 The use
9、 of a single-figure classification rating, “FieldImpact Insulation Class, FIIC” that can be used by architects,builders, and specification and code authorities for acousticalevaluation purposes in completed buildings. The FIIC isobtained by matching a standard reference contour to theplotted normali
10、zed one-third octave band sound pressure levelsat each test frequency obtained in accordance with this testmethod. For details regarding the derivation and significance ofthe FIIC, see Classification E 989.1.4 This standard does not purport to address all of thesafety concerns, if any, associated wi
11、th its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 634 Terminology Relating to Environmental AcousticsE 90 Test Met
12、hod for Laboratory Measurement ofAirborne-Sound Transmission Loss of Building Partitionsand ElementsE 336 Test Method for Measurement of Airborne SoundInsulation in BuildingsE 492 Test Method of Laboratory Measurement of ImpactSound Transmission Through Floor-Ceiling AssembliesUsing the Tapping Mach
13、ine1This test method is under the jurisdiction of ASTM Committee E33 onEnvironmental Acoustics and is the direct responsibility of Subcommittee E33.03 onSound Transmission.Current edition approved April 1, 2004. Published May 2004. Originallyapproved 1984. Last previous edition approved in 1997 as E
14、 1007 97.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive
15、, PO Box C700, West Conshohocken, PA 19428-2959, United States.E 597 Practice for Determining a Single-Number Rating ofAirborne Sound Isolation for Use in Multiunit BuildingSpecifications3E 966 Guide for Field Measurement of Airborne SoundInsulation of Building Facades and Facade ElementsE 989 Class
16、ification for Determination of Impact InsulationClass (IIC)2E 1408 Test Method for Laboratory Measurement of theSound Transmission Loss of Door Panels and Door Sys-temsE 1414 Test Method for Airborne Sound Attenuation Be-tween Rooms Sharing a Common Ceiling PlenumE 2235 Test Method for Determination
17、 of Decay Rates forUse in Sound Insulation Test Methods2.2 ANSI Standards:S1.4 Specification for Sound-Level Meters4S1.10 Pressure Calibration of Laboratory Standard PressureMicrophones4S1.11 Specification for Octave Band and Fractional-Octave-Band Analog and Digital Filters42.3 ISO Standard:ISO 140
18、AcousticsMeasurement of Sound Insulation inBuildings and of Building Elements; Part VILaboratoryMeasurement of Impact Sound Insulation of Floors, andPart VIIField Measurements of Impact Sound Insula-tion of Floors42.4 IEC Standard:IEC 804 Specification for Integrating Sound Level Meters3. Terminolog
19、y3.1 DefinitionsFor definitions of terms pertaining toacoustics used in this test method, see Terminology C 634.3.2 Definitions of Terms Specific to This Standard:3.2.1 source roomthe room containing the tapping ma-chine.3.2.2 receiving rooma room below or adjacent to the floorspecimen under test in
20、 which the impact sound pressure levelsare measured.NOTE 1The receiving room is usually the room below the floorspecimen but it may also be on the same level, diagonally below, or, insome cases, it could be above the source room.3.2.3 impact sound pressure levelthe average sound pres-sure level in a
21、 specified frequency band produced in thereceiving room by the operation of the standard tappingmachine on the floor assembly, averaged over each of thespecified machine positions.3.2.4 normalized impact sound pressure levelthe impactsound pressure level normalized to a reference absorption of 10m2(
22、108 sabins).3.2.5 field impact insulation class (FIIC)a single-numberrating derived from measured values of normalized one-thirdoctave band impact sound pressure levels in accordance withClassification E 989.NOTE 2FIIC provides an estimate of the sound insulating perfor-mance of a floor-ceiling asse
23、mbly and associated support structures undertapping machine excitation.4. Summary of Test Method4.1 A standard tapping machine is placed in operation on afloor specimen. The transmitted impact sound is characterizedby the one-third octave band spectrum of the average soundpressure level produced by
24、the tapping machine in the receiv-ing room located beneath or adjacent to the floor specimenunder test.4.2 Since the spectrum and level depend on the absorptionof the receiving room, the impact sound pressure levels arenormalized to a reference absorption for purposes of compar-ing results obtained
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME10072004E1STANDARDTESTMETHODFORFIELDMEASUREMENTOFTAPPINGMACHINEIMPACTSOUNDTRANSMISSIONTHROUGHFLOORCEILINGASSEMBLIESANDASSOCIATEDSUPPORTSTRUCTURES

链接地址:http://www.mydoc123.com/p-527722.html