《ASTM E314-2010 1250 Standard Test Methods for Determination of Manganese in Iron Ores by Pyrophosphate (Potentiometric) and Periodate (Photometric) Techniques《用焦磷酸盐(电势测定的)和高碘酸盐(测光的.pdf》由会员分享,可在线阅读,更多相关《ASTM E314-2010 1250 Standard Test Methods for Determination of Manganese in Iron Ores by Pyrophosphate (Potentiometric) and Periodate (Photometric) Techniques《用焦磷酸盐(电势测定的)和高碘酸盐(测光的.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E314 10Standard Test Methods forDetermination of Manganese in Iron Ores by Pyrophosphate(Potentiometric) and Periodate (Photometric) Techniques1This standard is issued under the fixed designation E314; the number immediately following the designation indicates the year oforiginal adopti
2、on or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the determination of manga-nese in iron ores, con
3、centrates, and agglomerates. The follow-ing two test methods are included:SectionsTest Method A (Pyrophosphate (Potentiometric) 8-15Test Method B (Periodate (Photometric) 16-221.2 Test Method A covers the determination of manganesein the concentration range from 2.5 % to 15.0 %. Test MethodB covers
4、the determination of manganese in the concentrationrange of 0.01 % to 5.00 %.NOTE 1The lower limit for this test method is set at 50 % relativeerror for the lowest grade material tested in the interlaboratory study inaccordance with Practice E1601.1.3 The values stated in SI units are to be regarded
5、 asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine t
6、he applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E50 Practices for Apparatus, Reagents, and Safety Consid-erations for Chemical Analysis of Metals, Ores, andRelated MaterialsE135 Terminology Relating to Analytical Chemistry forMetals, Ores, and Rela
7、ted MaterialsE173 Practice for Conducting Interlaboratory Studies ofMethods for Chemical Analysis of Metals3E877 Practice for Sampling and Sample Preparation of IronOres and Related Materials for Determination of ChemicalCompositionE882 Guide for Accountability and Quality Control in theChemical Ana
8、lysis LaboratoryE1601 Practice for Conducting an Interlaboratory Study toEvaluate the Performance of an Analytical Method3. Terminology3.1 DefinitionsFor definitions of terms used in these testmethods, refer to Terminology E135.4. Significance and Use4.1 This test method is intended to be used for c
9、ompliancewith compositional specifications for manganese content iniron ores, concentrates, and agglomerates. It is assumed that allwho use these procedures will be trained analysts capable ofperforming common laboratory procedures skillfully andsafely. It is expected that work will be performed in
10、a properlyequipped laboratory and that proper waste disposal procedureswill be followed. Appropriate quality control practices must befollowed such as those described in Guide E882.5. Reagents and Materials5.1 Purity and Concentration of ReagentsThe purity andconcentration of the common chemical rea
11、gents used shallconform to Practices E50. Special apparatus and reagentsrequired are located in separate sections preceding the proce-dure.6. Hazards6.1 For precautions to be observed in this method, refer toPractices E50.7. Sampling and Sample Preparation7.1 The gross sample shall be collected and
12、prepared inaccordance with Practice E877.1These test methods are under the jurisdiction of ASTM Committee E01 onAnalytical Chemistry for Metals, Ores, and Related Materials and are the directresponsibility of Subcommittee E01.02 on Ores, Concentrates, and Related Metal-lurgical Materials.Current edi
13、tion approved June 15, 2010. Published August 2010. Originallyapproved in 1966. Last previous edition approved in 2005 as E314 00 (2005).DOI: 10.1520/E0314-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of
14、ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United
15、 States.7.2 The analytical sample shall be pulverized to pass a No.100 (150-m) sieve.NOTE 2To facilitate decomposition some ores, such as specularhematites, may require grinding to pass a No. 200 (75-m) sieve.TEST METHOD APYROPHOSPHATE(POTENTIOMETRIC) METHOD8. Summary of Test Method8.1 The test samp
16、le is decomposed by treatment with HCl,NHO3, HF, and HClO4.After the addition of sodium pyrophos-phate and the adjustment of the acidity, the manganese isdetermined by oxidation to trivalent manganese with a standardsolution of potassium permanganate. The end point is deter-mined potentiometrically.
17、9. Interferences9.1 Provision has been made for the removal of chromiumwhich under some conditions is an interfering element.10. Apparatus10.1 pH MeterA number of pH meters are commerciallyavailable. Many of these instruments can accept a variety ofelectrodes and therefore can be used also for poten
18、tial mea-surements.Although both line- and battery-operated pH metersare manufactured, the former is recommended for laboratorywork because this type of pH meter contains an electronic ortransistorized potentiometer which makes the emf balancingoperation entirely automatic. Electrometer tube input i
19、s usedon both the electronic and transistorized pH meters.10.1.1 The pH meter must have electrode standardization(or asymmetry potential) and manual or automatic temperaturecompensation controls. The dial must read in pH directly, andpermit readings that are accurate to at least 6 0.01 pH unit. Forh
20、igher accuracies it is recommended that a pH meter with anexpanded scale be used.10.1.2 Because there is no accurate method for determiningthe absolute potential of an individual electrode, two electrodesare used for pH measurements. These are called the referenceand indicator electrodes. By interna
21、tional agreement the hy-drogen electrode is the standard indicator electrode for pH, butis inconvenient to use and subject to several limitations. Themost widely used reference electrode is the saturated calomelelectrode. It is most often used as a pencil-type unit that isimmersed directly in the so
22、lution, but may also be utilized asan external cell (to prevent possible contamination) contactingthe solution by means of a salt bridge. The silver-silverchloride reference electrode is also convenient to use, but it ismore difficult to prepare than the saturated calomel electrode.The mercurous sul
23、fate reference electrode may be used insolutions in which the chloride ions that diffuse out of thecalomel cell might be harmful.10.1.3 The most commonly employed indicator electrode isthe glass electrode. The quinhydrone and antimony-antimonous oxide electrodes are used to a much lesser extent.Comb
24、ination electrodes containing both the indicator andreference units are also available. The tips of the electrodescontaining solutions must be covered with rubber caps whenthe electrodes are disconnected from the meter and stored.When pH measurements are not being made the electrodesconnected to the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME31420101250STANDARDTESTMETHODSFORDETERMINATIONOFMANGANESEINIRONORESBYPYROPHOSPHATEPOTENTIOMETRICANDPERIODATEPHOTOMETRICTECHNIQUES

链接地址:http://www.mydoc123.com/p-527382.html