ASTM E102 E102M-1993(2016) 8812 Standard Test Method for Saybolt Furol Viscosity of Bituminous Materials at High Temperatures《高温沥青材料赛波特-傅洛粘度的标准试验方法》.pdf
《ASTM E102 E102M-1993(2016) 8812 Standard Test Method for Saybolt Furol Viscosity of Bituminous Materials at High Temperatures《高温沥青材料赛波特-傅洛粘度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E102 E102M-1993(2016) 8812 Standard Test Method for Saybolt Furol Viscosity of Bituminous Materials at High Temperatures《高温沥青材料赛波特-傅洛粘度的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E102/E102M 93 (Reapproved 2016)Standard Test Method forSaybolt Furol Viscosity of Bituminous Materials at HighTemperatures1This standard is issued under the fixed designation E102/E102M; the number immediately following the designation indicates the yearof original adoption or, in the c
2、ase of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the empirical procedures fordetermining the Saybolt Furol viscosi
3、ties of bituminous mate-rials at specified temperatures between 120 and 240C 248and 464F.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independen
4、tly of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and he
5、alth practices and determine the applica-bility of regulatory limitations prior to use. See 8.1.2. Referenced Documents2.1 ASTM Standards:2D88 Test Method for Saybolt ViscosityD92 Test Method for Flash and Fire Points by ClevelandOpen Cup TesterD140/D140M Practice for Sampling Bituminous MaterialsE1
6、 Specification for ASTM Liquid-in-Glass ThermometersE11 Specification for Woven Wire Test Sieve Cloth and TestSieves3. Terminology3.1 Definitions:3.1.1 Furolan acronym of “Fuel and road oils.”3.1.2 Saybolt Furol viscositythe corrected efflux time inseconds of 60 mL of sample flowing through a calibr
7、ated Furolorifice under specified conditions. The viscosity value isreported in Saybolt Furol seconds, abbreviated SFS, at aspecified temperature.4. Summary of Test Method4.1 The efflux time in seconds of 60 mL of sample, flowingthrough a calibrated orifice, is measured under carefullycontrolled con
8、ditions. The time is corrected by an orifice factorand reported as the viscosity of the sample at that temperature.5. Significance and Use5.1 This test method is useful in characterizing certainbituminous materials, as one element in establishing unifor-mity of shipments and sources of supply.5.2 Th
9、is test method is an extension of Test Method D88.6. Apparatus6.1 Saybolt Furol Viscometer and Bath, as shown anddescribed in Test Method D88, Fig. 1 andAnnex 1.An externalheater may also be used, but if so, it shall be more than 51 mm2 in. from the viscometer. An aluminum-block, constant-temperatur
10、e bath is also acceptable, and no stirring device isrequired with this type of bath.6.2 Displacement Ring, as shown in Fig. 1, constructed ofthe same corrosion-resistant metal as the viscometer.6.3 CoverA metal cover for the viscometer, cylindricalwith a flat top, approximately 57 mm 214 in. in diam
11、eter and7mm14 in. deep (Note 1). One hole slightly larger than thediameter of a viscosity thermometer shall be drilled in thecenter of the cover, and two smaller holes to permit the verticalrods of the displacement ring to pass through the cover.NOTE 1The cover of a 90-mL 3-oz Gill-style ointment bo
12、x fulfillsthese requirements.6.4 Thermometer Support, as shown in Test Method D88,Fig. 3.6.5 Saybolt Viscosity Thermometers, as listed in Table 1, forreading the temperature of the sample. Each thermometer shallconform to the requirements listed in Specification E1 for thatASTM Thermometer Number.1T
13、his test method is under the jurisdiction ofASTM Committee D08 on Roofingand Waterproofing and is the direct responsibility of Subcommittee D08.05 onSolvent-Bearing Bituminous Compounds for Roofing and Waterproofing.Current edition approved May 1, 2016. Published May 2016. Originallyapproved in 1954
14、. Last previous edition approved in 2009 as E102/E102M 93 (2009). DOI: 10.1520/E0102_E0102M-93R16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Docu
15、ment Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16.6 Bath ThermometersSaybolt Viscosity thermometers,or any other temperature-indicating means of equivalent accu-racy.6.7 Sieve, 850-m No. 20, confor
16、ming to the requirementsof Specification E11.6.8 Receiving Flask, as shown in Test Method D88, Fig. 5.6.9 Timer, graduated in fifths or tenths of a second, andaccurate to within 0.1 % when tested over a 60-min interval.Electric timers are acceptable if operated on a controlledfrequency circuit.6.10
17、Hot Plate, electric, approximately 200 mm 8 in. indiameter, with a three-heat switch, rated at 1200 W at the highheat setting and 500 to 600 W at the medium heat setting.7. Sampling7.1 Sample the material in accordance with Practice D140/D140M.8. Preparation of Apparatus8.1 Clean the viscometer thor
18、oughly with xylene, removeall solvent from the viscometer and its gallery, and dry well.Clean the displacement ring and receiving flask in the samemanner. Xylene is a toxic and flammable solvent; all workingareas shall be efficiently hooded and kept free of sparks andopen flames. If the viscometer i
19、s hot, vaporization of xylenecan be reduced by filling the tube rapidly and immediatelyallowing it to flow out through the orifice. A wooden toothpickmay be useful in cleaning the orifice.NOTE 2The viscometer may be kept clean by filling with cylinder oilimmediately after each test and allowing the
20、oil to remain in theviscometer for several minutes before draining and cleaning with xyleneas described above. If desired, the viscometer may be kept filled withcylinder oil between runs, draining and cleaning with xylene just beforeeach test.8.2 Set up the viscometer and bath in an area where theyw
21、ill not be exposed to drafts or rapid changes in airtemperature, and dust or vapors that might contaminate asample.8.3 Place the receiving flask beneath the viscometer so thatthe graduation mark on the flask is from 100 to 130 mm 4 to5 in. below the bottom of the viscometer tube, and so that thestre
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME102E102M199320168812STANDARDTESTMETHODFORSAYBOLTFUROLVISCOSITYOFBITUMINOUSMATERIALSATHIGHTEMPERATURES

链接地址:http://www.mydoc123.com/p-526840.html