ISO ASTM 51939-2017 Practice for blood irradiation dosimetry《血液辐照剂量测定的操作规程》.pdf
《ISO ASTM 51939-2017 Practice for blood irradiation dosimetry《血液辐照剂量测定的操作规程》.pdf》由会员分享,可在线阅读,更多相关《ISO ASTM 51939-2017 Practice for blood irradiation dosimetry《血液辐照剂量测定的操作规程》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、Practice for blood irradiation dosimetry Pratique de la dosimtrie pour lirradiation du sang INTERNATIONAL STANDARD ISO/ASTM 51939 Reference number ISO/ASTM 51939:2017(E) Fourth edition 2017-02 ISO/ASTM International 2017 ISO/ASTM 51939:2017(E)ii ISO/ASTM International 2017 All rights reserved COPYRI
2、GHT PROTECTED DOCUMENT ISO/ASTM International 2017, Published in Switzerland All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized otherwise in any form or by any means, electronic or mechanical, including photocopying, or posting on the internet
3、or an intranet, without prior written permission. Permission can be requested from either ISO at the address below or ISOs member body in the country of the requester. In the United States, such requests should be sent to ASTM International. ISO copyright office ASTM International Ch. de Blandonnet
4、8 CP 401 100 Barr Harbor Drive, PO Box C700 CH-1214 Vernier, Geneva, Switzerland West Conshohocken, PA 19428-2959, USA Tel. +41 22 749 01 11 Tel. +610 832 9634 Fax +41 22 749 09 47 Fax +610 832 9635 copyrightiso.org khooperastm.org www.iso.org www.astm.orgExplanatory Material This international stan
5、dard is part of the project between ISO and ASTM International to develop and maintain a group of ISO/ASTM dosimetry standards for radiation processing. In accordance with ISO/TC 85 N 1248, Maintenance Procedures for ISO/ASTM Radiation Processing Dosimetry Standards, a joint meeting of ISO/TC 85 WG3
6、 Dosimetry for Radiation Processing and ASTM Committee E61 was held in New Orleans, Louisiana, on January 16-28 to review standards being considered for withdrawal, revision/ amendment, or conrmation. Although ISO/ASTM 51939, published in 2005, had been reapproved in 2013, it was decided that this s
7、tandard should be revised to bring it in line with the new format adopted for the ISO/ASTM standards. A review was conducted to determine if, in addition to the format changes, technical changes would be required. From this review it was decided that major changes should be made to the standard and
8、that it should be revised as a major revision. The new standard covers the irradiation of blood or blood components in self-contained blood irradiators using photons. The previous version also covered the use of teletherapy equipment and electron beams. The standard provides recommendations for prop
9、erly implementing dosimetry in blood irradiation. The practice describes a means of achieving compliance with the requirments of ISO/ASTM Practice 52628 for dosimetry performed for blood irradiation and is intended to be read in conjunction with ISO/ASTM 52628. ISO/ASTM 51939:2017(E) ISO/ASTM Intern
10、ational 2017 All rights reserved ii-2 Contents Page 1 Scope . 1 2 Referenced documents 1 3 Terminology 2 4 Signicance and use 3 5 Type of irradiators and modes of operation. 4 6 Radiation source characteristics 4 7 Dosimetry systems. 5 8 Installation qualication 6 9 Operational qualication. 6 10 Per
11、formance qualication. 7 11 Routine product processing . 8 12 Maintenance of validation 9 13 Measurement uncertainty. 9 14 Keywords 9 Annexes 10 Table 1 Examples of reference-standard dosimetry systems 5 Table 2 Examples of routine dosimetry systems 6 Table A2.1 Recommended quality assurance steps fo
12、r blood irradiation 12 ISO/ASTM 51939:2017(E) ISO/ASTM International 2017 All rights reserved iii ISO/ASTM 51939:2017(E) Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International S
13、tandards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, als
14、o take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an Internati
15、onal Standard requires approval by at least 75% of the member bodies casting a vote. ASTM International is one of the worlds largest voluntary standards development organizations with global participation from affected stakeholders. ASTM technical committees follow rigorous due process balloting pro
16、cedures. A project between ISO and ASTM International has been formed to develop and maintain a group of ISO/ASTM radiation processing dosimetry standards. Under this project, ASTM Commitee E61, Radiation Processing, is responsible for the development and maintenance of these dosimetry standards wit
17、h unrestricted participation and input from appropriate ISO member bodies. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. Neither ISO nor ASTM International shall be held responsible for identifying any or all such patent rights.
18、 International Standard ISO/ASTM 51939 was developed by ASTM Committee E61, Radiation Processing, through Subcommittee E61.04, Specialty Application, and by Technical Committee ISO/TC 85, Nuclear energy, nuclear technologies and radiological protection. This fourth edition cancels and replaces the t
19、hird edition (ISO/ASTM 51939:05(2013), which has been technically revised. iv ISO/ASTM International 2017 All rights reservedISO/ASTM 51939:2017(E) Standard Practice for Blood Irradiation Dosimetry 1 This standard is issued under the xed designation ISO/ASTM FDIS 51939; the number immediately follow
20、ing the designation indicates the year of original adoption or, in the case of revision, the year of last revision. 1. Scope 1.1 This practice outlines the irradiator installation quali- cation program and the dosimetric procedures to be followed during operational qualication and performance qualic
21、ation of the irradiator. Procedures for the routine radiation process- ing of blood product (blood and blood components) are also given. If followed, these procedures will help ensure that blood product exposed to gamma radiation or X-radiation (bremsstrahlung) will receive absorbed doses with a spe
22、cied range. 1.2 This practice covers dosimetry for the irradiation of blood product for self-contained irradiators (free-standing irradiators) utilizing radionuclides such as 137 Cs and 60 Co, or X-radiation (bremsstrahlung). The absorbed dose range for blood irradiation is typically 15 Gy to 50 Gy.
23、 1.3 The photon energy range of X-radiation used for blood irradiation is typically from 40 keV to 300 keV . 1.4 This practice also covers the use of radiation-sensitive indicators for the visual and qualitative indication that the product has been irradiated (see ISO/ASTM Guide 51539). 1.5 This doc
24、ument is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing and describes a means of achieving compliance with the requirements of ISO/ASTM Practice 52628 for dosimetry performed for blood irradiation. It is intended to be read in conj
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISOASTM519392017PRACTICEFORBLOODIRRADIATIONDOSIMETRY 血液 辐照 剂量 测定 操作规程 PDF

链接地址:http://www.mydoc123.com/p-1256718.html