ASTM D7868-2013 1250 Standard Practice for Determining the Dry Fall (Fog) Properties of Protective Coatings《测定保护涂层过喷干燥(雾状)特性的标准实施规程》.pdf
《ASTM D7868-2013 1250 Standard Practice for Determining the Dry Fall (Fog) Properties of Protective Coatings《测定保护涂层过喷干燥(雾状)特性的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7868-2013 1250 Standard Practice for Determining the Dry Fall (Fog) Properties of Protective Coatings《测定保护涂层过喷干燥(雾状)特性的标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7868 13Standard Practice forDetermining the Dry Fall (Fog) Properties of ProtectiveCoatings1This standard is issued under the fixed designation D7868; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers a procedure for qualitatively evalu-ating the dry fall properties of coatings. The establishment ofthe
3、test environment and the evaluation procedures are de-scribed.1.2 This practice uses panels containing an automotivefinish since these types of surfaces are often the primaryconcern relating to overspray damage. Panels coated with othersystems may be used as collection surfaces when they aredeemed t
4、o be more representative.1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.4 This standard does not purport to address all of thesafe
5、ty concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D610 Practice for Evaluating Deg
6、ree of Rusting on PaintedSteel SurfacesD5402 Practice for Assessing the Solvent Resistance ofOrganic Coatings Using Solvent Rubs3. Terminology3.1 Definitions:3.1.1 dry/fall/fog coating, nan interior or exterior coatingspecially formulated so that the fine particles of overspray dryto a dust or powde
7、r during a free fall of a certain distance atspecific temperature and humidity ranges, and will not adhereto surfaces on which the overspray is subsequently deposited.4. Summary of Practice4.1 A structural frame is erected and enclosed. Spray targetsare placed inside the enclosure. Four steel panels
8、 coated withan automotive basecoat/clear coat system are placed on theenclosure floor to collect the dry fall. (Panels coated with othersystems or uncoated panels, or both, can be used when they aredeemed to be more representative.) A duplicate panel set ismaintained at the prevailing air temperatur
9、e, while the otherduplicate panel set is heated in oven and placed inside theenclosure immediately prior to atomizing the coating. Thecoating is atomized against the targets at each of two distancesand the panels are removed for evaluation. Two of the coatedsteel panels remain at laboratory ambient
10、conditions, while the“pre-heated” panels are returned to a laboratory oven. Theheated and ambient coated panels are cleaned and evaluatedafter 24-h for dry fall attachment.5. Significance and Use5.1 Attachment of overspray particles to vehicles and othersurfaces not intended to be coated can result
11、in propertydamage and insurance claims. Dry fall coatings are formulatedsuch that overspray particles dry as they move through the air,and before they land on horizontal surfaces. These particles canthen be brushed off, vacuumed or washed from the surfaceswith no damage. This practice can be used to
12、 evaluate the dryfall properties of coatings prior to large scale use. The practicecan also be used to evaluate whether the coating(s) possess thesame dry fall properties when the fallout collects on surfaceswith an elevated temperature.6. Reagents6.1 Commercially available Car Washing Concentrate.6
13、.2 Mineral Spirits.7. Procedure7.1 Construct a frame (enclosure) using steel conduit andcouplings or other materials of construction. The interior of theenclosure measures approximately 3 ft wide by 4 ft deep and is1This practice is under the jurisdiction of ASTM Committee D01 on Paint andRelated Co
14、atings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.46 on Industrial Protective Coatings.Current edition approved June 1, 2013. Published July 2013. DOI:10.1520D7868-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer S
15、ervice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States119 ft high in order to permit a dry fall t
16、est distance of 18 ft.3Enclose the frame with plastic sheeting or tarpaulins andsecure, making sure there is access at the base of the enclosureto add and remove the collection surfaces (coated panels). Abase constructed of plywood and protected with paper orplastic sheeting (that can be pushed in/p
17、ulled out to load/unload the panels) may be used. This requires the frame to beheightened approximately 2 in. from the floor surface usingwooden blocks or other methods (see Fig. 1).7.2 Fabricate and suspend (vertically) a spray target con-structed of18 in. by 3 by 3 ft wood or other rigid material
18、ontotwo hanging rods inside the enclosure. Mount troughs alongthe bottom edge of the target (optional) or position thecollection surfaces to prevent dripping coating on the dry fallcollection surfaces at the base of the enclosure. The spraytargets are positioned at the top of the enclosure to allow
19、a dryfall distance of 18 ft, and are positioned 48 ft and 24 ft from thespray gun tip (see 7.7 and 7.9). The spray targets shall bereplaced for each test to prevent build-up of wet coating on thetargets and potential dripping onto the dry fall collectionsurfaces at the base of the enclosure (See Fig
20、. 2).7.3 Mix and reduce (thin) the coating material according tothe manufacturers instructions, by the maximum amountpermitted. Record the material temperature. Atomize the coat-ing by airless spray (unless another spray method is mutuallyselected), using the pump pressure, hose diameter and tip siz
21、erecommended by the manufacturer. If the coating manufacturerrecommends a range of pump pressures and tip sizes, use thelowest pump pressure and the largest tip size (of the rangesrecommended) to create a worse case scenario. Record theactual pressure and tip size used, and the type, batch numberand
22、 amount of reducer used.7.4 Record the date and time of day. Measure and record theair temperature, relative humidity and dew point temperatureinside the enclosure. Testing should be performed when the airtemperature is between 60 and 80F (16 and 27C) and therelative humidity is between 40 and 85 %.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD786820131250STANDARDPRACTICEFORDETERMININGTHEDRYFALLFOGPROPERTIESOFPROTECTIVECOATINGS 测定 保护 涂层 干燥

链接地址:http://www.mydoc123.com/p-526451.html