ASTM D7853-2013 7500 Standard Test Method for Hydraulic Pullout Resistance of a Geomembrane with Locking Extensions Embedded in Concrete《带有嵌入混凝土中的锁紧扩展件的土工膜液压拉拔力的标准试验方法》.pdf
《ASTM D7853-2013 7500 Standard Test Method for Hydraulic Pullout Resistance of a Geomembrane with Locking Extensions Embedded in Concrete《带有嵌入混凝土中的锁紧扩展件的土工膜液压拉拔力的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7853-2013 7500 Standard Test Method for Hydraulic Pullout Resistance of a Geomembrane with Locking Extensions Embedded in Concrete《带有嵌入混凝土中的锁紧扩展件的土工膜液压拉拔力的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7853 13Standard Test Method forHydraulic Pullout Resistance of a Geomembrane withLocking Extensions Embedded in Concrete1This standard is issued under the fixed designation D7853; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the hy-draulic pullout resistance of a geomembrane
3、 with lockingextensions embedded in concrete by determining the pressurerequired for locking extensions of the embedded specimen topullout of the concrete.1.2 The values stated in SI units are to be regarded asstandard. The values given in parentheses are provided forinformation only and are not con
4、sidered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to us
5、e.2. Referenced Documents2.1 ASTM Standards:2A1064 Specification for Carbon-Steel Wire and WeldedWire Reinforcement, Plain and Deformed, for ConcreteC31 Practice for Making and Curing Concrete Test Speci-mens in the FieldC39 Test Method for Compressive Strength of CylindricalConcrete SpecimensC94 Sp
6、ecification for Ready-Mixed ConcreteD618 Practice for Conditioning Plastics for TestingD4439 Terminology for GeosyntheticsD5947 Test Methods for Physical Dimensions of SolidPlastics Specimens3. Terminology3.1 Definitions of terms applying to this test method appearin Terminology D4439.4. Summary of
7、Test Method4.1 A geomembrane with locking extensions on at least onesurface is embedded into concrete. The pullout resistance isdetermined by measuring the maximum pressure required toinitiate pullout of the locking extensions from the concrete.Alternatively, the geomembrane with locking extensions
8、isembedded in concrete and pressurized to a specified pressure toverify whether a minimum level of in-place strength has beenattained.5. Significance and Use5.1 Due to hydraulic pressure that may be present on someapplications, engineers need to understand the capability ofthese products to resist t
9、his pressure. This test allows engineersto compare products and verify pullout strength.5.2 Hydraulic pullout resistance is a function of lockingextension dimensions, locking extension geometry, lockingextensions per area, locking extension polymer composition,and the properties of the concrete in w
10、hich the lockingextensions are embedded.5.3 The data from this test method provides comparativeinformation for rating hydraulic pullout resistance of differentgeomembranes with locking extensions embedded in concrete.Hydraulic pullout resistance, while partly dependent on lock-ing extension dimensio
11、ns, has no simple correlation to lockingextension dimensions and geometry. Hence, hydraulic pulloutresistance cannot be determined with a small sample withoutpotentially producing misleading data to the actual hydraulicpullout resistance of the material. Therefore, the hydraulicpullout resistance is
12、 expressed in kPa (lbs/ft2).5.4 The apparatus can be circular or square in nature musthave a test area of 0.36 m2(558 in.2).5.5 Fig. 1 shows an example of a circular test apparatus thatcan be used in the performance of this test. The apparatusrequires a pressure vessel rated to a minimum 690 kPa (14
13、 410lbs/ft2). The vessel test diameter should be a minimum of677.04 mm (26.655 in.) as shown in Fig. 1.NOTE 1Larger vessels may be used but it is up to user to establishcorrelation to the standard size vessel. The use of a smaller diameter vesselthan denoted in standard may contribute to higher pull
14、out resistance dueto thickness or stiffness of some products.1This test method is under the jurisdiction of ASTM Committee on Geosynthet-ics and is the direct responsibility of Subcommittee D35.01 on MechanicalProperties.Current edition approved March 1, 2013. Published March 2013. DOI: 10.1520/D785
15、313.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO B
16、ox C700, West Conshohocken, PA 19428-2959. United States15.6 Test Pedestalthe base of the testing apparatus whichholds the test specimen.5.7 Upper Flangeis the flange that is bolted down on topof specimen to create a seal.5.8 Formis an aluminum ring used to form test specimenas shown in Fig. 2.5.9 S
17、pecimen Ringthe solid ring that is placed around testspecimen to contain leakage through the concrete.FIG. 1 Picture of Circular test apparatusFIG. 2 Bottom of Form with Studs facing up and cylinder spacerD7853 1325.10 The vessel will have a system to measure pressure.5.10.1 The system for measuring
18、 pressure shall be capableof being read to an accuracy of 3.5 kPa (0.5 psi).5.11 Concrete shall be a ready-mixed concrete per Specifi-cation C94 with a minimum cured compressive strength of34 473.8 kPa (5 000 psi).NOTE 2Alternate concrete or grout mixtures may be used for projectspecific application
19、s with the approval of the owner or engineer.5.12 All tests shall be conducted at standard laboratorytemperatures of 23 6 2C (73.4 6 3.6F).6. Test Specimens6.1 Cut the test specimens large enough to ensure a goodseal while maintaining a 677.04 mm (26.655 inches) indiameter testable specimen.6.2 Do n
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD785320137500STANDARDTESTMETHODFORHYDRAULICPULLOUTRESISTANCEOFAGEOMEMBRANEWITHLOCKINGEXTENSIONSEMBEDDEDINCONCRETE

链接地址:http://www.mydoc123.com/p-526420.html