ASTM D7706-2011 2500 Standard Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers《采用微空腔快速扫描产品的挥发性有机化合物排放物的标准操作规程》.pdf
《ASTM D7706-2011 2500 Standard Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers《采用微空腔快速扫描产品的挥发性有机化合物排放物的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7706-2011 2500 Standard Practice for Rapid Screening of VOC Emissions from Products Using Micro-Scale Chambers《采用微空腔快速扫描产品的挥发性有机化合物排放物的标准操作规程》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7706 11Standard Practice forRapid Screening of VOC Emissions from Products UsingMicro-Scale Chambers1This standard is issued under the fixed designation D7706; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice describes a micro-scale chamber apparatusand associated procedures for rapidly screening materials an
3、dproducts for their vapor-phase emissions of volatile organiccompounds (VOCs) including formaldehyde and other carbo-nyl compounds. It is intended to complement, not replacereference methods for measuring chemical emissions for ex-ample, small-scale chamber tests (Guide D5116) and emissioncell tests
4、 (Practice D7143).1.2 This practice is suitable for use in and outside oflaboratories, in manufacturing sites and in field locations withaccess to electrical power.1.3 Compatible material/product types that may be tested inthe micro-scale chamber apparatus include rigid materials,dried or cured pain
5、ts and coatings, compressible products, andsmall, irregularly-shaped components such as polymer beads.1.4 This practice describes tests to correlate emission resultsobtained from the micro-scale chamber with results obtainedfrom VOC emission reference methods (for example, GuideD5116, Test Method D6
6、007, Practice D7143, and ISO 16000-9and ISO 16000-10).1.5 The micro-scale chamber apparatus operates at moder-ately elevated temperatures, 30C to 60C, to eliminate theneed for cooling, to reduce test times, boost emission rates, andenhance analytical signals for routine emission screening, andto fac
7、ilitate screening of semi-volatile VOC (SVOC) emissionssuch as emissions of some phthalate esters and other plasticiz-ers.1.6 Gas sample collection and chemical analysis are depen-dent upon the nature of the VOCs targeted and are beyond thescope of this practice. However, the procedures described in
8、Test Method D7339, Practice D6196 and ISO 16000-6 foranalysis of VOCs and in Test Method D5197 and ISO 16000-3for analysis of formaldehyde and other carbonyl compoundsare applicable to this practice.1.7 The values stated in SI units are to be regarded asstandard. No other units of measurement are in
9、cluded in thisstandard.1.8 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior
10、 to use.2. Referenced Documents2.1 ASTM Standards:2D1356 Terminology Relating to Sampling and Analysis ofAtmospheresD1914 Practice for Conversion Units and Factors Relatingto Sampling and Analysis of AtmospheresD5116 Guide for Small-Scale Environmental Chamber De-terminations of Organic Emissions fr
11、om Indoor Materials/ProductsD5197 Test Method for Determination of Formaldehydeand Other Carbonyl Compounds in Air (Active SamplerMethodology)D6007 Test Method for Determining Formaldehyde Con-centrations in Air from Wood Products Using a Small-Scale ChamberD6196 Practice for Selection of Sorbents,
12、Sampling, andThermal Desorption Analysis Procedures for Volatile Or-ganic Compounds in AirD5337 Practice for Flow Rate Calibration of PersonalSampling PumpsD7143 Practice for Emission Cells for the Determination ofVolatile Organic Emissions from Indoor Materials/ProductsD7339 Test Method for Determi
13、nation of Volatile OrganicCompounds Emitted from Carpet using a Specific SorbentTube and Thermal Desorption / Gas Chromatography2.2 ISO Standards:3ISO 16000-3 Determination of formaldehyde and othercarbonyl compounds Active sampling methodISO 16000-6 Determination of volatile organic compounds1This
14、practice is under the jurisdiction of ASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.05 on Indoor Air.Current edition approved March 1, 2011. Published March 2011.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Serv
15、ice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 1
16、00 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.in indoor and test chamber air by active sampling onTenax TA sorbent, thermal desorption and gas-chromatography using MS/FIDISO 16000-9 Indoor airPart 9: Determination of theemission of volatile organic compounds Emis
17、sion testchamber methodISO 16000-10 Indoor airPart 10: Determination of theemission of volatile organic compounds Emission testcell method2.3 Other Standard:4US EPA Method TO-17 Determination of volatile organiccompounds in ambient air using active sampling ontosorbent tubes3. Terminology3.1 Definit
18、ionsFor definitions and terms commonly usedfor sampling and analysis of atmospheres, refer to TerminologyD1356. For definitions and terms commonly used when testingmaterials and products for VOC emissions, refer to GuideD5116. For an explanation of general units, symbols andconversion factors, refer
19、 to Practice D1914.3.2 Definitions of Terms Specific to This Standard:3.2.1 micro-scale test chamber, nan environmental testchamber ranging in volume from a few milliliters to about 150mL and designed to operate at moderately elevated tempera-tures that is used to measure vapor-phase organic emissio
20、nsfrom small specimens of solid materials and products.3.2.2 control level, na user-defined acceptance criterionfor a micro-scale chamber test, for example, presence orabsence of a target compound and/or a concentration oremission rate of a target compound, typically used in produc-tion quality cont
21、rol to indicate that the tested product samplelikely will meet the corresponding acceptance criterion for areference test.4. Principles4.1 Micro-scale test chambers operate under the same masstransfer principles as conventional small-scale test chambersand cells for measuring emissions of VOCs inclu
22、ding formal-dehyde and other carbonyl compounds from materials andproducts (see Guide D5116 and Practice D7143).4.2 Clean gas (dry nitrogen or air) is supplied to a micro-scale chamber and passes over the exposed surface of the testspecimen before reaching the exhaust point. The gas flow rateand tem
23、perature within the micro-scale chamber are controlled.As the gas passes over the test specimen, emitted compoundsare swept away from the surface.4.3 After the test specimen has equilibrated in the micro-scale chamber (typically for 20-40 minutes), a sampling deviceis connected to the outlet for col
24、lection of vapor-phase com-pounds exiting the chamber.5. Summary of Practice5.1 Micro-scale chambers can be used for rapid screeningand quality control of VOC emissions from many materials andproducts. Compatible sources include (with examples): rigidmaterials (plastics, wood-based panels, hard surf
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD770620112500STANDARDPRACTICEFORRAPIDSCREENINGOFVOCEMISSIONSFROMPRODUCTSUSINGMICROSCALECHAMBERS 采用

链接地址:http://www.mydoc123.com/p-526138.html