ASTM D7603-2013 red 3125 Standard Test Method for Determination of Storage Stability and Compatibility in Automotive Gear Oils《测定汽车齿轮油贮存稳定性和兼容性的标准试验方法》.pdf
《ASTM D7603-2013 red 3125 Standard Test Method for Determination of Storage Stability and Compatibility in Automotive Gear Oils《测定汽车齿轮油贮存稳定性和兼容性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7603-2013 red 3125 Standard Test Method for Determination of Storage Stability and Compatibility in Automotive Gear Oils《测定汽车齿轮油贮存稳定性和兼容性的标准试验方法》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7603 10D7603 13Standard Test Method forDetermination of Storage Stability and Compatibility inAutomotive Gear Oils1This standard is issued under the fixed designation D7603; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revis
2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This test method covers the determination of storage stability characteristics and the compati
3、bility of automotive gearlubricants when blended with reference lubricants. The purpose of the test is to determine if performance-enhancing additivesseparate out under defined conditions.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in
4、this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2.
5、Referenced Documents2.1 ASTM Standards:2D235 Specification for Mineral Spirits (Petroleum Spirits) (Hydrocarbon Dry Cleaning Solvent)D1193 Specification for Reagent WaterD4175 Terminology Relating to Petroleum, Petroleum Products, and LubricantsD5760 Specification for Performance of Manual Transmiss
6、ion Gear LubricantsE542 Practice for Calibration of Laboratory Volumetric ApparatusE1272 Specification for Laboratory Glass Graduated Cylinders2.2 SAE Standards:3J2360 Lubricating Oil, Gear Multipurpose (Metric) Military Use2.3 Federal Test Method Standard:4FED-STD-791/3440.1 Storage Solubility Char
7、acteristics of Universal Gear LubricantsFED-STD-791/3440.2 Compatibility Characteristics of Universal Gear Lubricants3. Terminology3.1 Definitions:3.1.1 calibrate, vto determine the indication or output of a measuring device (for example, thermometer, manometer, engine)with respect to that of a stan
8、dard.3.1.2 candidate oil, nan oil that is intended to have the performance characteristics necessary to satisfy a specification andis to be tested against that specification. D41753.1.3 reference oil, nan oil of known performance characteristics, used as a basis for comparison.3.1.3.1 Discussion1 Th
9、is test method is under the jurisdiction of ASTM Committee D02 on Petroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.B0.03D02.B0.01 on Automotive Gear Lubricants see 8.1.6.2 and 8.2.9.5). Store the tubes in the desiccator until required.8.1.3 Preparation of the Tes
10、t Oil:8.1.3.1 Thoroughly shake the test oil prior to sampling.8.1.3.2 Using a clean, dry, graduated cylinder (see 6.7.1), pour 220 mLof the test oil into a clean, dry beaker (400 mL) and heatin an oven controlled at 120 C 6 1 C for 20 min 6 1 min.8.1.3.3 Remove the beaker from the oven and allow to
11、cool to 25 C 6 3 C. Fill each centrifuge tube with test oil to the markat 100 mL. Stopper the tubes.8.1.4 Storing the Test OilStore the centrifuge tubes for 30 days 6 1 day. Place the tubes in an upright position in a darkenedarea (such as a drawer or cupboard) in a room whose temperature is control
12、led at 25 C 6 3 C.8.1.5 CentrifugingTransfer the tubes to the centrifuge, taking care not to disturb any material that may have separated fromthe oil. Operate the centrifuge for 30 min 6 1 min at a speed to give a rcf of 407 at the tips of the tubes (see 6.2).8.1.6 After centrifuging, remove the tub
13、es from the centrifuge and check each tube visually to determine if solid or liquidmaterial has separated out.8.1.6.1 If there is no visual evidence of separated material in the centrifuge tubes, stop the storage stability procedure, recordthat the storage stability test resulted in zero residue, an
14、d report as detailed in 9.1.1.8.1.6.2 If solid or liquid material has separated out, record that the storage stability test resulted in residue, and report as detailedin 9.1.2. If it is desired to quantify the amount of residue, proceed as directed in Appendix X1 and Appendix X2.5 ASTM Test Monitori
15、ng Center, 6555 Penn Ave., Pittsburgh, PA 152064489, www.standards.astmtmc.cmu.edu.6 The sole source of supply of the detergent known to the committee at this time is Alconox, 30 Glenn St., White Plains, NY, . Trademark of Alconox,30 Glenn St., White Plains, NY, . If you are aware of alternative sup
16、pliers, please provide this information to ASTM International Headquarters. Yourcomments will receive careful consideration at a meeting of the responsible technical committee,1 which you may attend.D7603 1348.2 Compatibility TestingIn general, when a mixture of a test oil and reference oil is store
17、d, residue can originate because ofincompatibility between the test oil and reference oil, or from a storage stability problem associated with the test and referenceoils themselves, or both. In the specific case of the reference oils SSCT Fluid (6-pack), the situation is simplified because they dono
18、t normally produce storage stability residues.NOTE 1In principle, therefore, any residue observed in the compatibility test involving these reference oils arises either from incompatibility betweenthe test oil and the reference oil or from storage stability problems from the test oil alone. In pract
19、ice, however, there is a possibility that the referenceoil(s) alone maymight produce residue during storage. For instance, the reference oil(s) maymight have deteriorated during storage, or have becomecontaminated, or the test maymight have been carried out incorrectly. To cover such eventualities,
20、the procedure requires that in the event a residue isobserved in the compatibility test with a test oil, the reference oil(s) involved are subjected to the storage stability test with a view to eliminating themas the source of residue.8.2.1 If desired, the compatibility testing canmay be carried out
21、 in parallel with the storage stability testing described in 8.1.8.2.2 Perform duplicate tests (that is, use two centrifuge tubes).8.2.3 Screen the Test Oil for Storage StabilitySubject the test oil alone (that is, not in combination with the reference oils) tothe storage stability test as described
22、 in 8.1.8.2.4 Preparation of the Centrifuge Tubes, Graduated Cylinders, and BeakersProceed as directed in 8.1.2.8.2.5 Preparation of the Test Oil/Reference Oil Mixtures:8.2.5.1 Thoroughly shake the test and reference oils prior to sampling.8.2.5.2 For each reference oil, use separate graduated cylin
23、ders (see 6.7.2) to pour 110 mL 6 1 mL each of the reference oiland the test oil into a clean, dry beaker (400 mL). Use the same graduated cylinder each time the test oil is measured, but a clean,dry, graduated cylinder for each of the reference oils. Heat the beakers containing the reference oil/te
24、st oil mixtures in an oven at120 C 6 1 C for 20 min 6 1 min.8.2.5.3 Remove the beakers from the oven and stir the contents while still hot for 5 min, using a mechanical stirrer operatedat approximately 200 r/min.8.2.5.4 Allow to cool to 25 C 6 3 C. Fill each centrifuge tube with reference oil/test o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD76032013RED3125STANDARDTESTMETHODFORDETERMINATIONOFSTORAGESTABILITYANDCOMPATIBILITYINAUTOMOTIVEGEAROILS

链接地址:http://www.mydoc123.com/p-525937.html