ASTM D7501-2009 838 Standard Test Method for Determination of Fuel Filter Blocking Potential of Biodiesel (B100) Blend Stock by Cold Soak Filtration Test (CSFT).pdf
《ASTM D7501-2009 838 Standard Test Method for Determination of Fuel Filter Blocking Potential of Biodiesel (B100) Blend Stock by Cold Soak Filtration Test (CSFT).pdf》由会员分享,可在线阅读,更多相关《ASTM D7501-2009 838 Standard Test Method for Determination of Fuel Filter Blocking Potential of Biodiesel (B100) Blend Stock by Cold Soak Filtration Test (CSFT).pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7501 09Standard Test Method forDetermination of Fuel Filter Blocking Potential of Biodiesel(B100) Blend Stock by Cold Soak Filtration Test (CSFT)1This standard is issued under the fixed designation D 7501; the number immediately following the designation indicates the year oforiginal
2、adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination by filtrationtime after co
3、ld soak of the suitability for a biodiesel (B100)blend stock that meets all other requirements of SpecificationD 6751 and has a cloud point below 68F (20C) to provideadequate low temperature operability performance to at leastthe cloud point of the finished blend.1.2 The formal precision of this tes
4、t method has not yet beendetermined. Interim precision for repeatability is included in13.1.1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered st
5、andard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Refer
6、enced Documents2.1 ASTM Standards:2D 4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD 5452 Test Method for Particulate Contamination in Avia-tion Fuels by Laboratory FiltrationD 6300 Practice for Determination of Precision and BiasData for Use in Test Methods for Petroleum Produ
7、cts andLubricantsD 6751 Specification for Biodiesel Fuel Blend Stock(B100) for Middle Distillate Fuels3. Terminology3.1 Definitions:3.1.1 biodiesel, nfuel comprised of mono-alkyl esters oflong chain fatty acids derived from vegetable oils or animalfats, designated as B100.3.1.2 bond, vto connect two
8、 parts of a system electricallyby means of a conductive wire to eliminate voltage differences.3.1.3 BXX blend, nfuel blend consisting of up to 20volume percent biodiesel designated as up to B20 conformingto the requirements of Specification D 6751 with the remainderbeing a light middle or middle dis
9、tillate grade diesel fuel andmeeting the requirements of this test method.3.1.3.1 DiscussionThe abbreviation BXX represents aspecific blend concentration in the range B2 to B20, where XXis the percent volume of biodiesel in the fuel blend.3.1.4 ground, vto connect electrically with earth.3.2 Definit
10、ions of Terms Specific to This Standard:3.2.1 air chamber, nunit to control temperature of samplefor cooling with maximum 0.5C variation from set point. Theunit shall use a microprocessor temperature controller withdigital set point and readout.Afood-grade refrigerator does notprovide adequate tempe
11、rature stability for this test method.3.2.2 minor component, nmaterial present in B100, typi-cally at concentrations well below 1% by mass.3.2.3 thermal history, nrange of temperatures that a batchor sample of B100 has experienced which can result inseparation or precipitation of minor components.3.
12、2.3.1 DiscussionCooling some biodiesel fuels can resultin precipitation or separation of minor components that havelimited solubility in B100. Heating these biodiesel fuels above40C is believed to redissolve most of these minor componentsand thus erase the thermal history of the sample.3.3 Abbreviat
13、ions:3.3.1 CSFTCold Soak Filtration Test4. Summary of Test Method4.1 In this test method, 300 mL of biodiesel (B100) is storedat 40 6 1F (4.5 6 0.5C) for 16 h, allowed to warm to 77 62F (25 6 1C), and vacuum filtered through a single 0.7 mglass fiber filter at controlled vacuum levels of 2125 in. of
14、 Hg.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.14 on Stability and Cleanliness of Liquid Fuels.Current edition approved April 1, 2009. Published April 2009.2For referenced ASTM standards, v
15、isit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428
16、-2959, United States.4.2 The filtration time is reported in seconds.5. Significance and Use5.1 Some substances that are soluble or appear to be solublein biodiesel (B100) at room temperature will, upon cooling totemperatures above the cloud point or standing at roomtemperature for extended periods,
17、come out of solution. Thisphenomenon has been observed in both B100 and BXX blends.These substances can cause filter plugging. This methodprovides an accelerated means of assessing the presence ofthese substances in B100 and their propensity to plug filters.5.1.1 B100 biodiesel fuels that give short
18、 filtration times areexpected to give satisfactory operation of BXX blends at leastdown to the cloud point of the biodiesel blends.5.2 The test method can be used in specifications as a meansof controlling levels of minor filter plugging components inbiodiesel and biodiesel blends.6. Apparatus6.1 Fi
19、ltration SystemArrange the following componentsas shown in Fig. 1.6.1.1 Funnel and Funnel Base, with a stainless steel filtersupport for a 47-mm diameter glass fiber filter, and locking ringor spring action clip, capable of receiving 300 mL.NOTE 1Sintered glass supports were found to give much highe
20、rfiltration times during initial studies and are not recommended to be used.6.1.2 Ground/Bond Wire, 0.912-2.59-mm (No. 10 throughNo. 19) bare stranded flexible, stainless steel or copperinstalled in the flasks and grounded as shown in Fig. 1.6.1.3 Electrical Bonding Apparatus, as described in TestMe
21、thod D 5452 or by using other suitable means of electricalgrounding that ensure safe operation of the filtration apparatusand flask.6.1.4 Receiving Flask, 1-L borosilicate glass vacuum filterflask, into which the filtration apparatus fits, and equipped witha sidearm to connect to the safety flask.6.
22、1.5 Safety Flask, 1-L borosilicate glass vacuum filter flaskequipped with a sidearm to connect the vacuum system. A fueland solvent resistant rubber hose, through which the groundingwire is connected to the sidearm of the receiving flask to thetube, passes through the rubber stopper in the top of th
23、e safetyflask.6.1.6 Vacuum System, capable of producing a vacuum of 70to 100 kPa below atmospheric pressure when measured at thesafety flask. A mechanical vacuum pump may be used if it hasthis capability.NOTE 2Water aspirated vacuum will not provide relative vacuumwithin the prescribed range.6.1.7 C
24、hilling Apparatus, either 6.1.7.1 or 6.1.7.2 may beused.6.1.7.1 Circulating Water Bath, capable of sustaining atemperature of 40 6 1F (4.5 6 0.5C).6.1.7.2 Air Chamber, capable of sustaining a temperature of40 6 1F (4.5 6 0.5C). The unit shall use microprocessortemperature control and have a digital
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD75012009838STANDARDTESTMETHODFORDETERMINATIONOFFUELFILTERBLOCKINGPOTENTIALOFBIODIESELB100BLENDSTOCKBYCOLDSOAKFILTRATIONTESTCSFTPDF

链接地址:http://www.mydoc123.com/p-525670.html