ASTM D7470-2008(2015) 2829 Standard Practice for Evaluating Elevated Temperature Performance of End-Jointed Lumber Studs《评估端拼木螺柱高温性能评价的标准实践规程》.pdf
《ASTM D7470-2008(2015) 2829 Standard Practice for Evaluating Elevated Temperature Performance of End-Jointed Lumber Studs《评估端拼木螺柱高温性能评价的标准实践规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7470-2008(2015) 2829 Standard Practice for Evaluating Elevated Temperature Performance of End-Jointed Lumber Studs《评估端拼木螺柱高温性能评价的标准实践规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7470 08 (Reapproved 2015)Standard Practice forEvaluating Elevated Temperature Performance of End-Jointed Lumber Studs1This standard is issued under the fixed designation D7470; the number immediately following the designation indicates the year oforiginal adoption or, in the case of re
2、vision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice is to be used to evaluate the elevatedtemperature performance of end-jointed lumber
3、studs.1.2 Asymmetric wall assembly containing end-jointed lum-ber studs is exposed to a standard fire exposure specified inTest Methods E119.1.3 End-jointed lumber studs are deemed qualified if thewall assembly resists a standard fire exposure specified in TestMethods E119 for a period of 60 min or
4、more. Qualification ofend-jointed lumber studs are restricted to the joint configura-tion and adhesive tested.1.4 This practice is used to evaluate the performance ofend-jointed lumber studs to heat and flame under controlledconditions, but does not by itself incorporate all factorsrequired for fire
5、 hazard or fire risk assessment under actual fireconditions.1.5 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. I
6、t is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C1396/C1396M Specification for Gypsum BoardD4688 Test Method for Evaluating Str
7、uctural Adhesives forFinger Jointing LumberD6513 Practice for Calculating the Superimposed Load onWood-frame Walls for Standard Fire-Resistance TestsE119 Test Methods for Fire Tests of Building Constructionand MaterialsF1667 Specification for Driven Fasteners: Nails, Spikes, andStaples2.2 Other Stan
8、dards:NDS National Design Specification for Wood Construction33. Terminology3.1 Definitions:3.1.1 end-jointed lumberLumber containing one or moreend-joints.3.1.2 end-jointsa joint formed by bonding two pieces oflumber end-to-end, often by machining a set of interlocking“fingers” (finger-joint) into
9、each end of adjoining pieces, usingan adhesive to form an adhesive bonded joint.3.1.3 qualified agencyan organization, hereafter referredto as the agency, that has trained personnel and procedures toensure the grades comply with all applicable requirements ofthis practice. The agency shall have no f
10、inancial interest in, norshall be financially dependent upon, any single companymanufacturing the product being inspected or tested; and shallnot be owned, operated, or controlled by any such company.4. Summary of Practice4.1 This practice shall be used to evaluate end-jointedlumber studs manufactur
11、ed with a specific joint configurationand adhesive. This practice is intended to be limited to theevaluation of end-jointed lumber studs with a specific jointconfiguration, adhesive, and limited design properties. Theresults are only applicable to end-jointed lumber studs using ajoint configuration
12、with the same number of fingers and afinger length of at least equal length as qualified in 7.1.2 andshall have assigned design properties no greater than the gradelevel qualified in 7.1.2.5. Significance and Use5.1 End-jointed lumber studs used in fire resistance-ratedassemblies shall be able to su
13、pport the superimposed design1This practice is under the jurisdiction of ASTM Committee D07 on Wood andis the direct responsibility of Subcommittee D07.02 on Lumber and EngineeredWood Products.Current edition approved May 1, 2015. Published June 2015. Originallyapproved in 2008. Last previous editio
14、n approved in 2008 as D7470 08. DOI:10.1520/D7470-08R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Avai
15、lable from American Wood Council (AWC), 1111 Nineteenth Street, NW,Suite 800, Washington, DC 20036, http:/www.awc.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1load for the specified time under an elevated temperatureexposure, w
16、hen a wall assembly is exposed to a standard firespecified in Test Methods E119. Light-weight wood assembliesutilize gypsum wallboard or other types of membrane protec-tion to accomplish a requisite fire resistance rating for theassembly. However, wood studs and the end-joints in the studsshall resi
17、st the developed elevated temperature environment forthe duration of the rating. This practice provides a method forevaluating the elevated temperature performance of an assem-bly constructed with end-jointed studs having fire performancecomparable to an assembly constructed with solid-sawn studs.6.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7470200820152829STANDARDPRACTICEFOREVALUATINGELEVATEDTEMPERATUREPERFORMANCEOFENDJOINTEDLUMBERSTUDS

链接地址:http://www.mydoc123.com/p-525590.html