《ASTM D7376-2010a 1250 Standard Practice for Outdoor Evaluation of Wet Stack Storage Conditions on Coil-Coated Metals《镀层金属盘材的潮湿堆放储存条件的室外评估的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7376-2010a 1250 Standard Practice for Outdoor Evaluation of Wet Stack Storage Conditions on Coil-Coated Metals《镀层金属盘材的潮湿堆放储存条件的室外评估的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7376 10aStandard Practice forOutdoor Evaluation of Wet Stack Storage Conditions onCoil-Coated Metals1This standard is issued under the fixed designation D7376; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice is used to determine the resistance tocorrosion and blistering of coil-coated metal products relative
3、to one another when stacked outdoors under direct weatheringconditions in which they are wetted by rain and dew.1.2 The coil-coated product variables evaluated may in-clude, but are not limited to, substrates, pretreatments, primers,topcoats, and backers.1.3 This test simulates a stacked building pa
4、nel bundlestored at a job site in wet outdoor conditions. The results frompanels tested during the same time period at the same physicallocation may be used to compare products as an indicator ofrelative field performance. Environments with higher tempera-ture and moisture levels accelerate corrosio
5、n and blistering.1.4 This standard does not endorse the storage of level (thatis, 0 from horizontal) building panels stacks in wet outdoorconditions. Level storage of building panels is not recom-mended and is used in this standard for evaluation only.1.5 The values stated in SI units are to be rega
6、rded as thestandard. The values given in parentheses are for informationonly.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determ
7、ine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D610 Practice for Evaluating Degree of Rusting on PaintedSteel SurfacesD714 Test Method for Evaluating Degree of Blistering ofPaintsD1654 Test Method for Evaluation of Painted or CoatedSpecimens
8、Subjected to Corrosive EnvironmentsG7 Practice for Atmospheric Environmental Exposure Test-ing of Nonmetallic Materials3. Summary of Practice3.1 This practice is for the evaluation of relative resistanceto wet stack corrosion and blistering of coil-coated metal. Thetest is to be conducted in an outd
9、oor environment withcoil-coated panels placed on a flat surface while allowingexposure to direct weather conditions including rain, dew, andsolar radiation.3.2 It is necessary to expose negative controls in each testrun, that is, products with known resistance to corrosion andblistering in this loca
10、tion, at the same time as the test productto determine its resistance relative to controls.3.3 Panels are evaluated periodically for corrosion andblistering as specified in 6.7.4. Significance and Use4.1 This practice provides for periodic testing for resistanceto wet conditions during storage to co
11、mpare the relativeperformance of specific combinations of coatings, substrates,and/or pretreatments used on coil-coated metal. The resultsmust be considered relative and do not indicate absoluteperformance.4.2 When stored improperly, coil-coated building panelstacks can be exposed to rainwater, whic
12、h flows into gapsbetween panels by capillary action or gravity, and remains inthe gaps because of poor drainage conditions. Such a conditionis known as a “wet stack” and may cause blistering andcorrosion of the painted surfaces. This practice simulates suchimproper storage conditions.4.3 Because the
13、 outdoor environment shows year-to-yearseasonal and geographic climate variation, the absolute amountof degradation based on corrosion and blistering may vary (seeAppendix X1).4.4 Temperature, rain, humidity, and storage practices areimportant factors in wet stack corrosion. Corrosion and blis-terin
14、g will accelerate with increased temperature. The pre-ferred test location is south of 27N latitude in Florida. Otherlocations may be used, but differences in temperature and1This practice is under the jurisdiction of ASTM Committee D01 on Paint andRelated Coatings, Materials, and Applications and i
15、s the direct responsibility ofSubcommittee D01.53 on Coil Coated Metal.Current edition approved June 1, 2010. Published June 2010. Originallyapproved in 2007. Last previous edition approved in 2010 as D7376 - 10. DOI:10.1520/D7376-10A.2For referenced ASTM standards, visit the ASTM website, www.astm.
16、org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.moisture mu
17、st be considered, and the amount of corrosion andblistering are expected to vary considerably with climate. Testsites must have the instrumentation to measure and recordambient temperature and rainfall as in Practice G7.4.5 This practice is not meant to support the field storage ofcoil-coated metal
18、in any way other than what is recommendedby the manufacturer.5. Apparatus5.1 The use of a wooden or plastic pallet to stack the testpanels in a horizontal position is one way to ensure rain doesnot puddle around the panels. Rainwater and condensation flowdown the sides of the stacks, and water is dr
19、awn betweenpanels by capillary action. Excess water will drain through theslats in the pallet (see Fig. 1).5.2 The pallet is recommended to be 61 cm to 91 cm (24 in.to 36 in.) from the ground and all foliage should be maintainedso that it does not create shade on or contact with the testpanels.5.3 W
20、ooden two by four boards of approximate cross-sectional dimensions, 4 cm by 9 cm (1.5 in by 3.5 in.) and ofthe required length are placed on top of the stacks (see Fig. 1).The pallets and boards shall be composed of untreated wood toavoid any influence from the treatment.5.4 The apparatus shall be p
21、laced in an unsheltered locationthat is subject to direct weathering conditions including rain,dew, and solar radiation.6. Procedure6.1 A wooden pallet or some flat surface with slats for waterdrainage is assembled in the required location. See Section 5.6.2 Test panels shall be gathered and cut to
22、the required size.A size of at least 15 cm by 15 cm (6 in. by 6 in.) is required.Duplicates of each panel are required to allow contact betweenthe topside and backside of the same sample Panels to becompared must be cut on the same metal shear with edge burrsoriented in the same direction. Edge resu
23、lts may be signifi-cantly influenced by burr differences. Corrosion ratings shallinclude any visible red or white corrosion products.6.3 A minimum of two extra panels shall be placed at thetop and two at the bottom of the stack to act as a barrier to anyinfluences from the wood or water accumulation
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD73762010A1250STANDARDPRACTICEFOROUTDOOREVALUATIONOFWETSTACKSTORAGECONDITIONSONCOILCOATEDMETALS 镀层

链接地址:http://www.mydoc123.com/p-525307.html