ASTM D7319-2011e1 7500 Standard Test Method for Determination of Existent and Potential Sulfate and Inorganic Chloride in Fuel Ethanol by Direct Injection Suppressed Ion Chromatogr.pdf
《ASTM D7319-2011e1 7500 Standard Test Method for Determination of Existent and Potential Sulfate and Inorganic Chloride in Fuel Ethanol by Direct Injection Suppressed Ion Chromatogr.pdf》由会员分享,可在线阅读,更多相关《ASTM D7319-2011e1 7500 Standard Test Method for Determination of Existent and Potential Sulfate and Inorganic Chloride in Fuel Ethanol by Direct Injection Suppressed Ion Chromatogr.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7319 111Standard Test Method forDetermination of Existent and Potential Sulfate andInorganic Chloride in Fuel Ethanol by Direct InjectionSuppressed Ion Chromatography1This standard is issued under the fixed designation D7319; the number immediately following the designation indicates t
2、he year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEUpdated 13.1 editorially in October 2011.1. Scope*1.1 Th
3、is test method covers a direct injection ion chromato-graphic procedure for determining existent and potential inor-ganic sulfate and total inorganic chloride content in hydrousand anhydrous denatured ethanol to be used in motor fuelapplications. It is intended for the analysis of ethanol samplescon
4、taining between 1.020 mg/kg of existent or potentialinorganic sulfate and 1.050 mg/kg of inorganic chloride.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety conce
5、rns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Material SafetyData Sheets are available for reagents and materials. Reviewthem fo
6、r hazards prior to usage.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD4052 Test Method for Density, Relative Density, and APIGravity of Liquids by Digital Density MeterD4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD4177 Practice for Automati
7、c Sampling of Petroleum andPetroleum ProductsD5827 Test Method for Analysis of Engine Coolant forChloride and Other Anions by Ion ChromatographyD6299 Practice for Applying Statistical Quality Assuranceand Control Charting Techniques to Evaluate AnalyticalMeasurement System PerformanceD6792 Practice
8、for Quality System in Petroleum Productsand Lubricants Testing LaboratoriesD7318 Test Method for Existent Inorganic Sulfate in Etha-nol by Potentiometric TitrationD7328 Test Method for Determination of Existent andPotential Inorganic Sulfate and Total Inorganic Chloride inFuel Ethanol by Ion Chromat
9、ography Using AqueousSample Injection2.2 European Norm Standards:3EN 15492 Ethanol as a blending component for petrol -Determination of inorganic chloride and sulfate content -Ion chromatographic method3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 existent inorganic sulfate,
10、 ninorganic sulfate speciesactually present in the sample at the time of analysis with nooxidation treatment.3.1.2 inorganic chloride, nchloride present as hydrochlo-ric acid, ionic salts of this acid, or mixtures of these.3.1.3 inorganic sulfate, nsulfate (SO4-2) species presentas sulfuric acid, io
11、nic salts of this acid, or mixtures of these.3.1.4 potential sulfate, ninorganic sulfate species presentafter the sample has been reacted with an oxidizing agent.4. Summary of Test Method4.1 For existent inorganic sulfate and total chloride, a smallvolume of an ethanol sample is directly injected in
12、to a suitablyconfigured ion chromatograph in accordance with manufactur-ers recommendations for this test method. For potentialsulfate, 0.5 mL of 30 % hydrogen peroxide solution is added to9.5 mL of the ethanol sample, and then injected into the ionchromatograph. Ions are separated based on their af
13、finity forexchange sites of the resin with respect to the resins affinity for1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.03 on Elemental Analysis.Current edition approved July 1, 2011. Publi
14、shed August 2011. Originallyapproved in 2007. Last previous edition approved in 2009 as D731909. DOI:10.1520/D7319-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer t
15、o the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Dri
16、ve, PO Box C700, West Conshohocken, PA 19428-2959, United States.the eluent. The suppressor increases the sensitivity of the testmethod by both increasing the conductivity of the analytes anddecreasing the conductivity of the eluent. It also converts theeluent and analytes to the corresponding hydro
17、gen forms ofanions. Anions are quantified by integration of their responsescompared with an external calibration curve, and are measuredas milligrams/litre, then converted to milligrams/kilograms.The calibration standards are prepared in an aqueous matrix.4.1.1 The use of acid suppression technology
18、 is moresignificant for the precision of sulfate measurement than forchloride. Sulfate precision will be worse if acid suppression isnot used.4.2 Similar methods for chloride and sulfate determinationscan be found in EN 15492 for total chloride, in Test MethodD7328 for total chloride and existent an
19、d potential inorganicsulfate by ion chromatography with aqueous sample injection,and in Test Method D7318 for existent inorganic sulfate bypotentiometric lead titration and Test Method D5827 forchloride and other anions in engine coolants by ion chroma-tography.5. Significance and Use5.1 Sulfates an
20、d chlorides can be found in filter pluggingdeposits and fuel injector deposits. The acceptability for use ofthe fuel components and the finished fuels depends on thesulfate and chloride content.5.2 Existent and potential inorganic sulfate and total chlo-ride content, as measured by this test method,
21、 can be used asone measure of the acceptability of gasoline components forautomotive spark-ignition engine fuel use.6. Interferences6.1 Interferences can be caused by substances with similarion chromatographic retention times, especially if they are inhigh concentration compared to the analyte of in
22、terest. Sampledilution can be used to minimize or resolve most interferenceproblems.6.2 A water dip (system void, negative peak as shown inFig. 1) can cause interference with some integrators. Usually,for chloride and sulfate determinations, the water dip shouldnot be a problem since the chloride an
23、d sulfate peaks are faraway from the water dip.6.3 Given the trace amounts of chloride and sulfate deter-mined in this test method, interferences can be caused bycontamination of glassware, eluent, reagents, and the like. Forexample, sodium leaching from glassware can precipitate withsulfate giving
24、low sulfate results. Take care to ensure thatcontamination is kept at the lowest possible levels. The use ofpowder-free gloves is highly recommended to prevent samplecontamination.7. Apparatus7.1 Analytical Balance, capable of weighing up to 100 gaccurately to 0.0001 g.7.2 Drying Oven, controlled at
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD73192011E17500STANDARDTESTMETHODFORDETERMINATIONOFEXISTENTANDPOTENTIALSULFATEANDINORGANICCHLORIDEINFUELETHANOLBYDIRECTINJECTIONSUPPRESSEDIONCHROMATOGRPDF

链接地址:http://www.mydoc123.com/p-525128.html