ASTM D7200-2006 Standard Practice for Sampling and Counting Airborne Fibers Including Asbestos Fibers in Mines and Quarries by Phase Contrast Microscopy and Transmission Electron M.pdf
《ASTM D7200-2006 Standard Practice for Sampling and Counting Airborne Fibers Including Asbestos Fibers in Mines and Quarries by Phase Contrast Microscopy and Transmission Electron M.pdf》由会员分享,可在线阅读,更多相关《ASTM D7200-2006 Standard Practice for Sampling and Counting Airborne Fibers Including Asbestos Fibers in Mines and Quarries by Phase Contrast Microscopy and Transmission Electron M.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7200 06Standard Practice forSampling and Counting Airborne Fibers, Including AsbestosFibers, in Mines and Quarries, by Phase ContrastMicroscopy and Transmission Electron Microscopy1This standard is issued under the fixed designation D 7200; the number immediately following the designa
2、tion indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice2describes the dete
3、rmination of the con-centration of fibers, expressed as the number of such fibers permillilitre of air, using phase contrast microscopy and optionallytransmission electron microscopy to evaluate particulate mate-rial collected on a membrane filter in the breathing zone of anindividual or by area sam
4、pling in a specific location. Thispractice is based on the core procedures provided in theInternational Organization for Standardization (ISO) StandardISO 8672(1)3, the National Institute for Occupational andHealth (NIOSH) Manual of Analytical Methods, NIOSH 7400(2), and the Occupational Safety and
5、Health Administration(OSHA) Method ID 160 (3). This practice indicates the impor-tant points where these methods differ, and provides informa-tion regarding the differences. However, selecting portions ofprocedures from different published methods generally re-quires a user to report that they have
6、used a modification to amethod rather than claim they have used the method as written.This practice further gives guidance on how differential count-ing techniques may be used to indicate where a population offibers may be asbestos.1.2 The practice is used for routine determination of anindex of occ
7、upational exposure to airborne fibers in mines,quarries, or other locations where ore may be processed orhandled. The method gives an index of airborne fiber concen-tration. The method provides an estimate of the fraction ofcounted fibers that may be asbestos. This practice should beused in conjunct
8、ion with electron microscopy (See AppendixX1) for assistance in identification of fibers.1.3 This practice specifies the equipment and procedures forsampling the atmosphere in the breathing zone of an individualand for determining the number of fibers accumulated on afilter membrane during the cours
9、e of an appropriately-selectedsampling period. The method may also be used to sample theatmosphere in a specific location in a mine or in a room of abuilding (area sampling).1.4 The ideal working range of this practice extends from100 fibers/mm2to 1300 fibers/mm2of filter area. For a 1000-Lair sampl
10、e, this corresponds to a concentration range fromapproximately 0.04 to 0.5 fiber/mL (or fiber/cm3). Lower andhigher ranges of fiber concentration can be measured byreducing or increasing the volume of air collected. However,when this practice is applied to personal sampling in mines andquarries, the
11、 level of total suspended particulate may impose anupper limit to the volume of air that can be sampled if the filtersproduced are to be of appropriate particulate loading for fibercounting.1.5 Users should determine their own limit of detectionusing the procedure in Practice D 6620. For reference,
12、theNIOSH 7400 method gives the limit of detection as 7 fibers/mm2of filter area. For a 1000-L air sample, this corresponds toa limit of detection of 0.0027 fiber/mL (or fiber/cm3). ForOSHA ID 160 the limit of detection is given as 5.5 fibers/mm2of filter area. For a 1000-L air sample, this correspon
13、ds to alimit of detection of 0.0022 fiber/mL (or fiber/cm3).1.6 If this practice yields a fiber concentration that does notexceed one-half the permissible exposure limit or thresholdlimit value for the particular regulated fiber variety, no furtheraction may be necessary. If the fiber concentration
14、exceedsone-half of the regulated permissible exposure limit or thresh-old limit value for the particular regulated fiber variety,examine the data to determine if more than 50 % of the countedfibers may be bundles, fibers longer than 10 m, or fibersthinner than 1.0 m. If these counts exceed 50 % of t
15、he totalcount, then there is an increased possibility that asbestos ispresent in the sample. Use the optional method specified inAppendix X1 to measure the concentration or proportion of thefibers counted that is of the regulated variety. If asbestos fibers1This practice is under the jurisdiction of
16、ASTM Committee D22 onAir Qualityand is the direct responsibility of Subcommittee D22.04 onWorkplaceAtmospheres.Current edition approved June 1, 2006. Published July 2006.2This test method is based on NIOSH 7400, OSHA Method ID 60, andISO 8672. Users of this ASTM standard are cautioned that if they w
17、ish to complywith one of these specific procedures exactly they should follow that procedure,otherwise they should document the modification.3Boldface numbers in parentheses refer to the list of references appended to thismethod.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West
18、 Conshohocken, PA 19428-2959, United States.are identified by this method, the mine/quarry operator shouldconduct a geological survey of the property to identify thesource of the fibers.1.7 The mounting medium used in this practice has arefractive index of approximately 1.45. Fibers with refractivei
19、ndices in the range of 1.4 to 1.5 will exhibit reduced contrast,and may be difficult to detect.1.8 Fibers less than approximately 0.2 m in diameter maynot be detected by this practice. (4)1.9 This standard may involve hazardous materials, opera-tions, and equipment. This standard does not purport to
20、address all of the safety problems associated with its use. It isthe responsibility of the user of this standard to establishappropriate safety and health practices and determine theapplicability of regulatory limitations prior to use. For specificprecautionary statements, see Section 7.2. Reference
21、d Documents2.1 ASTM Standards:4D 257 Test Methods for DC Resistance or Conductance ofInsulating MaterialsD 1356 Terminology Relating to Sampling and Analysis ofAtmospheresD 1357 Practice for Planning the Sampling of the AmbientAtmosphereD 3670 Guide for Determination of Precision and Bias ofMethods
22、of Committee D22D 5337 Practice for Flow Rate Calibration of PersonalSampling PumpsD 6620 Practice for Asbestos Detection Limit Based onCounts2.2 Other StandardsNIOSH 7400 National Institute of Occupational Health andSafety (Revised 1994).5(RTM 1) Asbestos InternationalAssociation (AIA), Recom-mende
23、d Technical Method No.1.6ID 160 Occupational Safety and Health Administration(OSHA).ISO 8672 International Organization for Standardization.3. Terminology3.1 Description of terms specific to this practice, in additionto those found in Terminology D 1356:3.1.1 asbestosa term applied to six specific s
24、ilicate min-erals belonging to the serpentine and amphibole groups, whichhave crystallized in the asbestiform habit, causing them to beeasily separated into long, thin, flexible, strong fibers whencrushed or processed (5). The Chemical Abstracts ServiceRegistry Numbers of the most common asbestos va
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD72002006STANDARDPRACTICEFORSAMPLINGANDCOUNTINGAIRBORNEFIBERSINCLUDINGASBESTOSFIBERSINMINESANDQUARRIESBYPHASECONTRASTMICROSCOPYANDTRANSMISSIONELECTRONMPDF

链接地址:http://www.mydoc123.com/p-524793.html