ASTM D7183-2012 2500 Standard Test Method for Determination of Total Sulfur in Aromatic Hydrocarbons and Related Chemicals by Ultraviolet Fluorescence《紫外荧光法测定芳烃和相关化合物中总硫度的标准试验方法》.pdf
《ASTM D7183-2012 2500 Standard Test Method for Determination of Total Sulfur in Aromatic Hydrocarbons and Related Chemicals by Ultraviolet Fluorescence《紫外荧光法测定芳烃和相关化合物中总硫度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7183-2012 2500 Standard Test Method for Determination of Total Sulfur in Aromatic Hydrocarbons and Related Chemicals by Ultraviolet Fluorescence《紫外荧光法测定芳烃和相关化合物中总硫度的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7183 12Standard Test Method forDetermination of Total Sulfur in Aromatic Hydrocarbons andRelated Chemicals by Ultraviolet Fluorescence1This standard is issued under the fixed designation D7183; the number immediately following the designation indicates the year oforiginal adoption or,
2、in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of sulfur inaromatic hydrocarbons, the
3、ir derivatives, and related chemi-cals.1.2 This test method is applicable to samples with sulfurconcentrations from 0.5 to 100 mg/kg.1.3 The following applies for the purposes of determiningthe conformance of the test results using this test method toapplicable specifications, results shall be round
4、ed off in accor-dance with the rounding-off method of Practice E29.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It
5、is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see Section 9.2. Referenced Documents2.1 ASTM Standards:2D1555 Test Method for Calculation o
6、f Volume and Weightof Industrial Aromatic Hydrocarbons and CyclohexaneD3437 Practice for Sampling and Handling Liquid CyclicProductsD6809 Guide for Quality Control and Quality AssuranceProcedures for Aromatic Hydrocarbons and Related Ma-terialsE29 Practice for Using Significant Digits in Test Data t
7、oDetermine Conformance with SpecificationsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 Other DocumentsOSHA Regulations, 29 CFR paragraphs 1910.1000 and1910.120033. Terminology3.1 oxidative pyrolysis, na process in which a sample iscombusted in a
8、n oxygen-rich atmosphere at high temperatureto break down the components of the sample into elementaloxides.3.2 ultraviolet fluorescence, nradiation in the region ofthe electromagnetic spectrum including wavelength from 100to 3900A that excites SO2to (SO2*).4. Summary of Test Method4.1 A specimen is
9、 either directly injected or placed in asample boat. The boat is then inserted into a high temperaturecombustion tube where the sulfur is oxidized to sulfur dioxide(SO2) in an oxygen-rich atmosphere. Water produced duringthe sample combustion is removed and the sample combustiongases are next expose
10、d to ultraviolet (UV) light. The SO2absorbs the energy from the UV light and is converted toexcited sulfur dioxide (SO2*). As it returns to a stable state,light is emitted and detected by a photomultiplier tube and theresulting signal is a measure of the sulfur contained in thespecimen.5. Significan
11、ce and Use5.1 Some process catalysts used in petroleum and chemicalrefining can be poisoned when trace amounts of sulfur-bearingmaterials are contained in the feedstocks. This test method can1This test method is under the jurisdiction of ASTM Committee D16 onAromatic Hydrocarbons and Related Chemica
12、ls and is the direct responsibility ofSubcommittee D16.04 on Instrumental Analysis.Current edition approved Jan. 1, 2012. Published January 2012. Originallyapproved in 2007. Last previous edition approved in 2007 as D7183 - 071. DOI:10.1520/D7183-12.2For referenced ASTM standards, visit the ASTM web
13、site, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop:
14、SDE, Washington, DC 20401, http:/www.access.gpo.gov.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.be used to determine sulfur in process feeds, sulfur in finishedpro
15、ducts, and can also be used for purposes of regulatorycontrol.6. Interferences6.1 Halogens present in the specimen in concentrationsgreater than 10 % and nitrogen concentrations of 1500 mg/kgor greater can interfere.6.2 Moisture produced during the combustion step caninterfere if not removed prior t
16、o the gas entering the detectorcell.7. Apparatus7.1 Pyrolysis FurnaceAn electric furnace capable ofmaintaining a temperature sufficient to volatilize and pyrolyzeall the sample and oxidize sulfur to SO2. The actual tempera-ture should be recommended by specific instrument manufac-turer.7.2 Quartz Py
17、rolysis TubeCapable of withstanding 900 to1200C. The tube should be recommended by the instrumentmanufacturer.7.3 Microlitre SyringeCapable of delivering from 5 to250 L of sample. Check with the instrument manufacturer forrecommendations for specific sample requirements.7.4 Constant Rate Injector Sy
18、stemIf the sample is to beintroduced into the pyrolysis furnace via syringe, use aconstant rate injector or a liquid introduction module.7.5 Liquid Auto-SamplerCapable of injecting 5 to 250 Lof sample.7.6 Automatic Boat Drive SystemIf the instrument isequipped with an inlet system, a device for driv
19、ing the boatinto the furnace at a controlled and repeatable rate is required.7.7 Flow ControlThe instrument must be equipped withflow controllers capable of maintaining a constant supply ofoxygen and carrier gas.7.8 Drier TubeThe instrument must be equipped with amechanism for removal of water vapor
20、.8. Reagents8.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. It is intended that all reagents shall conform tothe specifications of the Committee on Analytical Reagents ofthe American Chemical Society,4where such specifications areavailable, unless otherwise indicated. Other
21、grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.8.2 Inert GasEither argon (Ar) or helium (He) may beused. The purity should be no less than 99.99 mol %.8.3 Oxygen GasThe purity sho
22、uld be no less than 99.99mol %.8.4 SolventThe solvent chosen should be capable ofdissolving the sulfur compound. The solvent of choice shouldhave a boiling point similar to the sample being analyzed.Suggested possibilities include, but not limited to methanol,iso-octane, and p-xylene (see Note 1 and
23、 Note 2).NOTE 1A quick screening can be conducted by injecting the solventand sample once or twice and comparing relative area counts.NOTE 2All solvents should have known sulfur content or known to beless than what will interfere with results.8.5 DibenzothiopheneFW184.26, 17.399 % (m/m) Sulfur(see N
24、ote 3).NOTE 3A correction for chemical impurity is required. Normally98 %.8.6 Quartz WoolIf needed.8.7 Sulfur Stock Solution, approximately 870 to 1044 gS/mlThis standard may be purchased if desired. Prepare astock solution by accurately weighing approximately 0.5 to 0.6g of dibenzothiophene to the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD718320122500STANDARDTESTMETHODFORDETERMINATIONOFTOTALSULFURINAROMATICHYDROCARBONSANDRELATEDCHEMICALSBYULTRAVIOLETFLUORESCENCE

链接地址:http://www.mydoc123.com/p-524739.html