ASTM D7133-2005 Standard Test Method for Polyurethane Raw Materials Instrumental Measurement of Tristimulus CIELAB Color and Yellowness Index of Liquids《聚氨酯原材料的标准试验方法 液体三色CIELAB颜色和.pdf
《ASTM D7133-2005 Standard Test Method for Polyurethane Raw Materials Instrumental Measurement of Tristimulus CIELAB Color and Yellowness Index of Liquids《聚氨酯原材料的标准试验方法 液体三色CIELAB颜色和.pdf》由会员分享,可在线阅读,更多相关《ASTM D7133-2005 Standard Test Method for Polyurethane Raw Materials Instrumental Measurement of Tristimulus CIELAB Color and Yellowness Index of Liquids《聚氨酯原材料的标准试验方法 液体三色CIELAB颜色和.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7133 05Standard Test Method forPolyurethane Raw Materials: Instrumental Measurement ofTristimulus CIELAB Color and Yellowness Index of Liquids1This standard is issued under the fixed designation D 7133; the number immediately following the designation indicates the year oforiginal ado
2、ption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method provides an instrumental method formeasuring the CIEL
3、AB color and Yellowness Index (YI) ofliquid polyurethane raw materials. The CIELAB and YI resultsare derived from mathematical manipulation of CIE tristimulusvalues in accordance with Practices E 308 and E 313, respec-tively.1.2 See Section 5 for cautions in using this test method.1.3 This standard
4、does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1There is no equivalent ISO
5、standard.2. Referenced Documents2.1 ASTM Standards:2D 883 Terminology Relating to PlasticsD 1193 Specification for Reagent WaterE 180 Practice for Determining the Precision of ASTMMethods for Analysis and Testing of Industrial and Spe-cialty ChemicalsE 284 Terminology of AppearanceE 308 Practice for
6、 Computing the Colors of Objects byUsing the CIE SystemE 313 Practice for Calculating Yellowness and WhitenessIndices from Instrumentally Measured Color CoordinatesE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Terminology3.1 DefinitionsFor defini
7、tions of terms that appear in thistest method, refer to Terminologies E 284, D 883, and theterminology section of Practice E 308.4. Summary of Test Method4.1 The color of the total transmitted light is measured by aspectrophotometer in CIE tristimulus values under CIE stan-dard illuminant D65 and CI
8、E 1964 supplementary standardobserver commonly called the 10 standard observer. Thesevalues are then converted by the appropriate equations to theCIELAB color scale and the Yellowness Index. L*a*b* and YIvalues are reported.5. Significance and Use5.1 CIELAB is a visual-based scale that can be used t
9、ospecify color and set color tolerances for the polyurethaneindustry.5.2 Yellowness Index specifies the degree of departure ofthe sample from colorless towards yellow. This index is onlysuitable for clear liquids with degrees of saturation in yellow(dominant transmission wavelength in the 570 to 580
10、 nmrange). It can be used to set tolerances for appropriatepolyurethane raw materials.5.3 This test method does not include provisions for mate-rials with fluorescence or visible haze (usually greater than 5 %haze).5.4 Before proceeding with this test method, make referenceto the specification of th
11、e material being tested. Any testspecimen preparation, conditioning, dimensions, or testingparameters or combination thereof, covered in the materialsspecification shall take precedence over those mentioned in thistest method. If there are no material specifications, then thedefault conditions apply
12、.6. Interferences6.1 This test method is to be used to compare samples onlywhen they are measured under the same conditions.6.1.1 The medium in the cuvette used during standardiza-tion of the instrument will have an effect on the measuredresults. Light mineral oil is recommended, however, distilledw
13、ater can be used as a substitute but a note of the substitutionmust be included in any report of the results.6.1.2 The temperature of the sample is also expected toaffect the results obtained.1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibilit
14、y of Subcommittee D20.22 on Cellular MaterialsPlastics and Elastomers.Current edition approved Dec. 15, 2005. Published January 2006.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume infor
15、mation, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7. Apparatus7.1 InstrumentA hemispherical geometry (integratingsphere) spectrophotometer capable of total transmi
16、ssion (TT-RAN) CIE tristimulus measurement through a cuvette. TT-RAN includes both the regularly transmitted portion and thediffused portion of the incident light. The instrument must becapable of converting CIE XYZ tristimulus values to theCIELAB color scale as defined in Practice E 308 using CIED6
17、5 standard illuminant and 10 standard observer. Theinstrument must also be capable of converting CIE XYZtristimulus values to the Yellowness Index value defined inPractice E 313 using CIE D65 standard illuminant and 10standard observer. The instrument is to meet the manufactur-ers requirements for c
18、alibration. For highly transparentsamples, such as the polyols below, spectrophotometers ortristimulus colorimeters without a spherical geometry can beused with equivalent results.7.2 Sample CuvettesThe cuvette must have a 20 6 0.06mm pathlength. The entrance and exit windows shall beparallel, color
19、less, clear and unaffected by the material beinganalyzed. The optical properties of the cuvette used duringstandardization of the instrument and the cuvette used formeasuring samples (if not the same cuvette) must be matched.This can be determined by proving that the variation, if any, inthe differe
20、nt cuvettes used do not affect the measured value ofa standard sample. Glass or plastic cuvettes can be used.8. Reagents8.1 Mineral OilColorless NF or FCC grade light mineraloil.8.2 Distilled WaterColorless distilled water conformingto Type IV of Specification D 1193.9. Sampling and Test Specs and U
21、nits9.1 Test samples are to be homogeneous and representativeof the liquid being tested.9.2 Do not touch the entrance and exit windows of thecuvette through which incident and transmitted light will passexcept to clean them.9.3 The CIELAB values, L*, a*, and b*, have no unitsassociated with them.9.4
22、 The Yellowness Index value, YI, has no unit associatedwith it.10. Calibration and Standardization10.1 Calibration procedures vary from manufacturer tomanufacturer. They are important to ensure accurate data.Include the following periodic system verification steps:10.1.1 Wavelength Scale Verificatio
23、nThis can be donewith a didymium filter.10.1.2 Photomeric Scale VerificationThis is to be done inaccordance with manufacturers instructions with a certifiedliquid standard. An APHA standard is suitable. Linearity isestablished using at least two different standard concentrations.10.1.3 Selection of
24、Instrument Variables10.1.3.1 Select CIE illuminant D65 and 10 standard ob-server.10.1.3.2 Select the total transmission (TTRAN) mode un-less instructed by the manufacturer to use a different mode forthe verification procedure.10.2 Pour mineral oil into a clean cuvette. Ensure that liquidcompletely c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD71332005STANDARDTESTMETHODFORPOLYURETHANERAWMATERIALSINSTRUMENTALMEASUREMENTOFTRISTIMULUSCIELABCOLORANDYELLOWNESSINDEXOFLIQUIDS

链接地址:http://www.mydoc123.com/p-524583.html