ASTM D7082-2004(2010) 8750 Standard Specification for Polyethylene Stay In Place Form System for End Walls for Drainage Pipe《排水管端壁的聚乙烯固定型系统标准规范》.pdf
《ASTM D7082-2004(2010) 8750 Standard Specification for Polyethylene Stay In Place Form System for End Walls for Drainage Pipe《排水管端壁的聚乙烯固定型系统标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7082-2004(2010) 8750 Standard Specification for Polyethylene Stay In Place Form System for End Walls for Drainage Pipe《排水管端壁的聚乙烯固定型系统标准规范》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7082 04 (Reapproved 2010)Standard Specification forPolyethylene Stay In Place Form System for End Walls forDrainage Pipe1This standard is issued under the fixed designation D7082; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification addresses the requirements for poly-ethylene stay in place forms for end wal
3、ls or head walls for usewith standard storm drainage systems.1.2 The wall form system consists of a base wall form, acap, an optional riser to adjust the height of the wall above thepipe, and an optional adaptor to adjust the pipe opening toaccommodate smaller pipe sizes.1.3 The form system is manuf
4、actured using the rotationalmolding process and is available in different colors.1.4 The values stated in SI units are to be regarded as thestandard, the inch-pounds in brackets are given for informationonly.1.5 This standard does not purport to address all of thesafety concerns, if any, associated
5、with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory requirements prior to use.NOTE 1There is no known ISO equivalent to this standard.2. Referenced Documents2.1 ASTM Standards:2D638 Te
6、st Method for Tensile Properties of PlasticsD648 Test Method for Deflection Temperature of PlasticsUnder Flexural Load in the Edgewise PositionD790 Test Methods for Flexural Properties of Unreinforcedand Reinforced Plastics and Electrical Insulating MaterialsD883 Terminology Relating to PlasticsD123
7、8 Test Method for Melt Flow Rates of Thermoplasticsby Extrusion PlastometerD1505 Test Method for Density of Plastics by the Density-Gradient TechniqueD1600 Terminology for Abbreviated Terms Relating toPlasticsD1693 Test Method for Environmental Stress-Cracking ofEthylene PlasticsD4883 Test Method fo
8、r Density of Polyethylene by theUltrasound TechniqueD5033 Guide for Development of ASTM Standards Relat-ing to Recycling and Use of Recycled Plastics33. Terminology3.1 DefinitionsDefinitions used in this specification are inaccordance with definitions in Terminology D883 and abbre-viations in accord
9、ance with Terminology D1600 unless other-wise indicated.3.1.1 end walla wall installed at the outlet of a stormdrainage pipe.3.1.2 head walla wall installed at the inlet of a stormdrainage pipe.4. Ordering Information4.1 Number and color of base wall forms,4.2 Number and color of riser forms,4.3 Num
10、ber and color of caps, and4.4 Number, color and size of adaptors.5. Materials and Manufacture5.1 The material used shall be a polyethylene meeting thecriteria in Table 1.5.2 Only virgin materials (Guide D5033) shall be used.5.3 This product shall be manufactured using a rotationalmolding process.6.
11、Requirements6.1 Wall System Description:6.1.1 Base wall form is hollow with opening at the top toaccept fill material and designed to accept either cap or risersection. Base wall has opening in the center for pipe andadaptors as needed. Pipe is secured to base wall form withgalvanized screws. (See F
12、ig. 1.)1This specification is under the jurisdiction of ASTM Committee D20 onPlastics and is the direct responsibility of Subcommittee D20.24 on Plastic BuildingProducts.Current edition approved April 1, 2010. Published June 2010. Originallyapproved in 2004. Last previous edition approved in 2004 as
13、 D7082 - 04. DOI:10.1520/D7082-04R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last app
14、roved version of this historical standard is referencedon www.astm.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.1.2 Riser form is hollow with opening at top to accept fillmaterial and cap section. Multiple risers can be inst
15、alled onbase wall. (See Fig. 2.)6.1.3 Cap fits on top of base wall or riser and is secured withgalvanized screws. (See Fig. 1.)6.1.4 Adaptor section is used to adjust the size of the pipeopening as needed. Adaptor is secured to base wall form withgalvanized screws and pipe is secured to adaptor with
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7082200420108750STANDARDSPECIFICATIONFORPOLYETHYLENESTAYINPLACEFORMSYSTEMFORENDWALLSFORDRAINAGEPIPE

链接地址:http://www.mydoc123.com/p-524447.html