《ASTM D7066-2004e1 317 Standard Test Method for dimer trimer of chlorotrifluoroethylene (S-316) Recoverable Oil and Grease and Nonpolar Material by Infrared Determination《用红外测定法测定三氟.pdf》由会员分享,可在线阅读,更多相关《ASTM D7066-2004e1 317 Standard Test Method for dimer trimer of chlorotrifluoroethylene (S-316) Recoverable Oil and Grease and Nonpolar Material by Infrared Determination《用红外测定法测定三氟.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7066 04e1An American National StandardStandard Test Method fordimer/trimer of chlorotrifluoroethylene (S-316) RecoverableOil and Grease and Nonpolar Material by InfraredDetermination1This standard is issued under the fixed designation D 7066; the number immediately following the desig
2、nation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEAdded research report reference to S
3、ection 15 editorially in March 2008.1. Scope1.1 This test method covers the determination of oil andgrease and nonpolar material in water and wastewater by aninfrared (IR) determination of dimer/trimer of chlorotrifluoro-ethylene (S-316) extractable substances from an acidifiedsample. Included in th
4、is estimation of oil and grease are anyother compounds soluble in the solvent.1.2 The method is applicable to measurement of the lightfuel although loss of some light ends during extraction can beexpected.1.3 This method defines oil and grease in water and waste-water as that which is extractable in
5、 the test method andmeasured by IR absorption at 2930 cm-1or 3.4 microns.Similarly, this test method defines nonpolar material in waterand wastewater as that oil and grease which is not adsorbed bysilica gel in the test method and measured by IR absorption at2930 cm-1.1.4 This method covers the rang
6、e of 5 to 100 mg/L and maybe extended to a lower or higher level by extraction of a largeror smaller sample volume collected separately.1.5 This standard does not purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this standard to es
7、tablish appro-priate safety and health practices and determine (D 3856Guide for Good Laboratory Practices2) the applicability ofregulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:D 1129 Terminology Relating to WaterD 1193 Specification for Reagent WaterD 3370 Practices for
8、 Sampling Water from Closed ConduitsD 3856 Guide for Good Laboratory Practices Engaged inSampling and Analysis of WaterD 2777 Practice for the Determination of Precision andBias of Applicable Methods of Committee D19 on WaterD 5810 Guide for Spiking into Aqueous SamplesD 5847 Practice for Writing Qu
9、ality Control Specificationsfor Standard Test Methods for Water AnalysisE 168 Practices for General Techniques of Infrared Quanti-tative AnalysisE 178 Practice for Dealing With Outlying Observations3. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod, refer to Terminology D
10、1129 and Practices E 168.3.2 Definitions of Terms Specific to This Standard:3.2.1 oil and greasethe organic matter extracted fromwater or wastewater and measured by this test method.3.2.2 nonpolar materialthe oil and grease remaining insolution after contact with silica gel and measured by this test
11、method.3.2.3 solventdimer/trimer of chlorotrifluoroethylene (S-316)4. Summary of Test Method4.1 An acidified 250-mL sample of water or wastewater isextracted serially with three 15-mL volumes of dimer/trimer ofchlorotrifluoroethylene (S-316). The extract is diluted to 50mLand a portion is examined b
12、y infrared spectroscopy (IR) for anoil and grease measurement.3A portion of the extract iscontacted with silica gel to remove polar substances, therebyproducing a solution containing nonpolar material. The non-polar material is measured by infrared spectroscopy.1This test method is under the jurisdi
13、ction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.06 on Methods forAnalysis forOrganic Substances in Water.Current edition approved June 1, 2004. Published July 2004.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer S
14、ervice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Consult the manufacturers operation manual for the specific instructionsrelated to the infrared spectrometer or analyzer to be used.1Copyright ASTM Interna
15、tional, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Significance and Use5.1 The presence and concentration of oil and grease indomestic and industrial wastewater is of concern to the publicbecause of its deleterious aesthetic effect and its impact onaquatic
16、 life.5.2 Regulations and standards have been established thatrequire monitoring of oil and grease in water and wastewater.6. Interferences6.1 Soaps, detergents, surfactants and other materials mayform emulsions that may reduce the amount of oil and greaseextracted from a sample. This test method co
17、ntains proceduresthat can assist the analyst in breaking such emulsions.6.2 Organic compounds and other materials not consideredas oil and grease on the basis of chemical structure may beextracted and measured as oil and grease. Of those measured,certain ones may be adsorbed by silica gel while othe
18、rs maynot. Those not adsorbed are measured as nonpolar material.7. ApparatusAll glassware that will come in contact with the sample mustbe rinsed with dimer/trimer of chlorotrifluoroethylene (S-316)prior to beginning this procedure.7.1 Cell(s), quartz, 10-mm path length (lower concentra-tions may re
19、quire a longer pathlength), two required fordouble-beam operation, one required for single-beam opera-tion, or built-in or drop-in cell for infrared filtometer analyzeroperation.7.2 Filter Paper, ashless, quantitative, general-purpose, 11-cm, Whatman #40 or equivalent.7.3 Glass Funnel7.4 Glass Wide
20、Mouth Sample Bottle, minimum 250-mL,with screw cap having a fluoropolymer liner.7.5 Glass Graduated Cylinder, 100-mL7.6 Infrared Spectrometer, double-beam dispersive, single-beam dispersive, Fourier transform, filtometers or other ca-pable of making measurements at 2930 cm-1.7.7 Magnetic Stirrer, wi
21、th small TFE-fluorocarbon stirringbar.7.8 Glass Separatory-Funnel, 500mL, with fluoropolymerstopcock and stopper.7.9 Volumetric Flasks, glass, various (10, 25, 50, 100, and200-mL)7.10 Teflon spritz bottle, one-piece wash bottle for rinsing7.11 Repeating pipetter, glass, 15-mL, (optional)7.12 Volumet
22、ric Pipettes, glass, various (0.50, 1.00, 5.00,10.0 and 25.0-mL, including a 1.00 serological pipet graduatedin 0.01-mL increments and a 5.00-mL serological pipet gradu-ated in 0.1-mL increments, or equivalent)7.13 Benchtop shaker, (optional)7.14 Glass Stirring Rod, (optional)7.15 Analytical Balance
23、,7.16 Syringes, 50 and 500 mL8. Reagents8.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specification of the Committeeon Analytical Reagents of the American Chemical Society,where such specifica
24、tions are available. Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.8.2 Purity of WaterUnless otherwise indicated, referencesto laboratory or reagent water shall be understo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD70662004E1317STANDARDTESTMETHODFORDIMERTRIMEROFCHLOROTRIFLUOROETHYLENES316RECOVERABLEOILANDGREASEANDNONPOLARMATERIALBYINFRAREDDETERMINATION

链接地址:http://www.mydoc123.com/p-524427.html