ASTM D7013-2004 Standard Guide for Nuclear Surface Moisture and Density Gauge Calibration Facility Setup《核表面湿度和密度量规校准设施装配的标准指南》.pdf
《ASTM D7013-2004 Standard Guide for Nuclear Surface Moisture and Density Gauge Calibration Facility Setup《核表面湿度和密度量规校准设施装配的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7013-2004 Standard Guide for Nuclear Surface Moisture and Density Gauge Calibration Facility Setup《核表面湿度和密度量规校准设施装配的标准指南》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7013 04Standard Guide forNuclear Surface Moisture and Density Gauge CalibrationFacility Setup1This standard is issued under the fixed designation D 7013; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of la
2、st revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide outlines procedures for setup of nuclearmoisture density gauge in shielded, Method A, and unshielded,Method
3、B, configurations.1.2 This guide does not attempt to describe the calibrationtechniques or methods. It is assumed that this guide will beused by persons familiar with the operations of the gauge andin performing proper calibration, service and maintenance.1.3 This guide does not attempt to address m
4、aintenance orservice procedures related to the gauge.1.4 This guide does not purport to address all of the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this guide to establish appropriate safety, andhealth practices and determine the applicability of regula
5、torylimitations prior to use.1.5 This guide offers an organized collection of informationor a series of options and does not recommend a specificcourse of action. This document cannot replace education orexperience and should be used in conjunction with professionaljudgment. Not all aspects of this
6、guide may be applicable in allcircumstances. This ASTM standard is not intended to repre-sent or replace the standard of care by which the adequacy ofa given professional service must be judged, nor should thisdocument be applied without consideration of a projects manyunique aspects. The word “Stan
7、dard” in the title of thisdocument has been approved through ASTM consensus pro-cess.1.6 All observed and calculated values shall conform to theguidelines for significant digits and rounding established inpractice D 6026.1.6.1 The method used to specify how data are collected,calculated, or recorded
8、 in this standard is not directly relatedto the accuracy to which the data can be applied in the designor other uses, or both. How one applies the results obtainedusing this standard is beyond its scope.2. Referenced Documents2.1 ASTM Standards:2D 2922 Standard Test Method for Density of Soil andSoi
9、l-Aggregate in Place by Nuclear Methods (ShallowDepth)D 653 Terminology Relating to Rock, Soil and ContainedFluidsD 3740 Standard Practice for Minimum Requirements forAgencies Engaged in the Testing and/or Inspection of Soiland Rock as Used in engineering Design and ConstructionD 6026 Standard Pract
10、ice for Using Significant Digits inGeotechnical Data3. Terminology3.1 For common definitions of terms refer to TerminologyD 6533.2 Definitions of Terms Specific to This Standard:3.2.1 Unshielded Calibration bayAn open area within acalibration facility where the closest wall is a minimum of 1meter (3
11、 ft.) from the spot in which the gauge is beingcalibrated.3.2.2 Shielded Calibration bayAn enclosed area sur-rounded by concrete blocks or walls to protect the gauge beingcalibrated from outside influence and background radiationfrom all gauges in the facility.3.2.3 Shielded Storage BayAn enclosed a
12、rea shielded bywalls to maintain and control radiation background in thefacility and to reduce influences from stored gauges.4. Summary of Method4.1 Nuclear moisture density gauges require proper calibra-tion to ensure measurement repeatability between gauges.Since these gauges contain radioactive i
13、sotopes, influencesfrom the surroundings and other gauges should be controlledduring the calibration process. This guide provides procedures1This guide is under the jurisdiction ofASTM Committee D18 on Soil and Rockand is the direct responsibility of Subcommittee D18.08 on Special and Construc-tion
14、Control Tests.Current edition approved Dec. 1, 2004. Published December 2004.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page ont
15、he ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.to facilities involved in calibration of one or more gauges inshielded and unshielded calibration bays. The goal of thisguide is to insure proper gauge calibration and t
16、o reduceinfluences that would result in field measurement variabilitybetween gauges.5. Significance and Use5.1 Gauge calibration is conducted for the following pur-poses:5.1.1 To ensure gauge measurement repeatability betweengauges5.1.2 To correct for electronic and mechanical changes overtime5.1.3
17、To adjust readings after major service to the gauge5.2 To establish a proper calibration area for gauges5.3 To reduce the chance of improper calibrationNOTE 1The quality of the results produced by this standard isdependent on the competence of the personnel performing it, and thesuitability of the e
18、quipment and facilities used. Agencies that meet thecriteria of practice D 3740 are generally considered capable of competentand objective testing/inspection/etc. Users of this standard are cautionedthat compliance with practice D 3740 does not in itself assure a means ofevaluating some of those fac
19、tors.6. Apparatus6.1 Calibration reference block(s) as per the requirements ofASTM D 2922 with density certification from the blockmanufacturer6.2 High density concrete blocks 9cm 3 20 cm 3 41 cm(3.59 3 89 3 169) or cinder blocks 20 cm 3 20 cm 3 41 cm(89 3 89 3 169) filled with sand or other fine ag
20、gregatematerials for construction of bay walls6.3 Lead sheet 1 to 6 mm (0.032 to 0.25 inches) thick forlining the bay walls. The exposed surfaces containing leadshould be painted or covered6.4 Plywood of minimum 1.3 cm (0.59) thickness forsecuring lead sheets to the calibration bay walls.7. Method A
21、: Shielded Calibration Bay Setup7.1 Set up a shielded calibration bay if more than one gaugeis going to be calibrated simultaneously, and the space betweengauges being calibrated is less than 10 meter (33 ft). If thegauge in storage bay is less than 7 meters (23 ft) from the areawhere the calibratio
22、n is going to take place, or if the area wheregauges are routinely serviced is less than 10 meters (33 ft) fromthe calibration area. Refer to the Appendix X1 for examples ofshielded calibration bay configurations.NOTE 2Use Method B, if section 7.1 does not fit your calibrationfacility requirements.7
23、.1.1 Determine the number of bays required for calibrationof nuclear gauges. This can be based on the number of gaugescalibrated per year and can vary from one to several bays.7.1.2 The bay inside dimensions should be establishedbased on the bay walls being a minimum of 610 mm (24inches) from the ce
24、nter of calibration blocks and lined with 1mm (0.032 inches) of lead. Smaller inside dimensions can beused if lead sheets thicker than 6 mm (0.25 inch) are used onthe walls. However, under no circumstances should the wallsbe less than 610 mm (24 inches) from center of the gauge.NOTE 3Depending on th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD70132004STANDARDGUIDEFORNUCLEARSURFACEMOISTUREANDDENSITYGAUGECALIBRATIONFACILITYSETUP 表面 湿度 密度 量规

链接地址:http://www.mydoc123.com/p-524250.html