1、Designation: D7013/D7013M 15Standard Guide forCalibration Facility Setup for Nuclear Surface Gauges1This standard is issued under the fixed designation D7013/D7013M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year of last
2、revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This guide outlines procedures for setup of a nucleargauge calibration facility in either a shielded bay or anunshielded a
3、reaGuide A and Guide B, respectively.1.2 This guide does not attempt to describe the calibrationtechniques or methods. It is assumed that this guide will beused by persons familiar with the operations of the gauge andin performing proper calibration, service and maintenance.1.3 This guide does not a
4、ttempt to address maintenance orservice procedures related to the gauge.1.4 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other.
5、 Combiningvalues from the two systems may result in non-conformancewith the standard.1.5 This guide does not purport to address all of the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this guide to establish appropriate safety, andhealth practices and deter
6、mine the applicability of regulatorylimitations prior to use.1.6 This guide offers an organized collection of informationor a series of options and does not recommend a specificcourse of action. This document cannot replace education orexperience and should be used in conjunction with professionalju
7、dgment. Not all aspects of this guide may be applicable in allcircumstances. This ASTM standard is not intended to repre-sent or replace the standard of care by which the adequacy ofa given professional service must be judged, nor should thisdocument be applied without consideration of a projects ma
8、nyunique aspects. The word “Standard” in the title of thisdocument has been approved through ASTM consensus pro-cess.1.7 All observed and calculated values shall conform to theguidelines for significant digits and rounding established inpractice D6026.1.7.1 The method used to specify how data are co
9、llected,calculated, or recorded in this standard is not directly relatedto the accuracy to which the data can be applied in the designor other uses, or both. How one applies the results obtainedusing this standard is beyond its scope.2. Referenced Documents2.1 ASTM Standards:2D653 Terminology Relati
10、ng to Soil, Rock, and ContainedFluidsD3740 Practice for Minimum Requirements for AgenciesEngaged in Testing and/or Inspection of Soil and Rock asUsed in Engineering Design and ConstructionD6026 Practice for Using Significant Digits in GeotechnicalDataD6938 Test Method for In-Place Density and Water
11、Contentof Soil and Soil-Aggregate by Nuclear Methods (ShallowDepth)3. Terminology3.1 For definitions of common technical terms in thisstandard, refer to Terminology D653.3.2 Definitions of Terms Specific to This Standard:3.2.1 cinder blocka hollow building block made withconcrete and coal cinders.3.
12、2.2 high density concrete blockssolid concrete blocksdesigned for areas requiring radiation shielding.3.2.3 safe positionposition of the density source duringthe standardization process of the gauge.3.2.4 shielded calibration bayan enclosed area sur-rounded by walls in order to reduce background rad
13、iation to anacceptable level.3.2.5 shielded storage bayan enclosed area with sufficientshielding material to maintain and control radiation back-ground in the facility and to reduce influences from storedgauges.1This guide is under the jurisdiction ofASTM Committee D18 on Soil and Rockand is the dir
14、ect responsibility of Subcommittee D18.08 on Special and Construc-tion Control Tests.Current edition approved May 1, 2015. Published June 2015. Originallyapproved in 2004. Last previous edition approved in 2011 as D701311. DOI:10.1520/D7013_D7013M-15.2For referenced ASTM standards, visit the ASTM we
15、bsite, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor
16、 Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.6 unshielded areaan open area within a calibrationfacility where the closest wall is a minimum of1m3ftfromthe spot in which the gauge is being calibrated.4. Summary of Method4.1 Nuclear moisture density gauges require proper ca
17、libra-tion. Since these gauges contain radioactive isotopes, influ-ences from the surroundings and other gauges should becontrolled during the calibration process. This guide providesprocedures to facilities involved in calibration of one or moregauges in a shielded bay or and an unshielded area. Th
18、e goal ofthis guide is to provide a calibration and storage facility forproper gauge calibration.5. Significance and Use5.1 To establish a proper calibration area for nuclear surfacegauges.5.2 To reduce the chance of improper calibration.NOTE 1The quality of the results produced by this standard isd
19、ependent on the competence of the personnel performing it, and thesuitability of the equipment and facilities used. Agencies that meet thecriteria of practice D3740 are generally considered capable of competentand objective testing/inspection/etc. Users of this standard are cautionedthat compliance
20、with practice D3740 does not in itself assure a means ofevaluating some of those factors.6. Apparatus6.1 Calibration reference block(s) as per the requirements ofTest Method D6938 with density certification from a qualifiedcalibration facility.6.2 High density concrete blocks 9 cm high 20 cm wide 41
21、 cm long 3.5 in. 8 in. 16 in. or cinder blocks 20 cm high 20 cm wide 41 cm long 8 in. 8 in. 16 in. filled withsand or other fine aggregate materials for construction of baywalls.6.3 Lead sheet 1 to 6 mm 0.032 to 0.25 in. thick for liningthe bay walls. The exposed surfaces containing lead should bepa
22、inted or covered.6.4 Miscellaneous hardware for securing lead sheets to thecalibration bay walls.7. Shielded Storage Bay Setup7.1 Set up a shielded storage bay if more than five gaugesare routinely stored at a distance of 10 m 33 ft or less fromthe area where gauge calibration is to take place. If f
23、ive or lessgauges are routinely stored in the storage area, concrete wallsare not necessary. However, gauges should be stored in theirshipping cases or likewise secured while other gauges arebeing calibrated. Refer to Appendix X1 for examples ofshielded storage bay configurations.7.1.1 The storage b
24、ay should not be set up directly under orover the area where gauges are to be calibrated.7.1.2 Stagger the blocks during wall construction to reducegaps between blocks and to improve wall integrity.7.1.3 If more than five gauges are routinely stored in thestorage bay, build a wall made from high den
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD7013D7013M20159029STANDARDGUIDEFORCALIBRATIONFACILITYSETUPFORNUCLEARSURFACEGAUGES 表面 量规 使用 校准 设施

链接地址:http://www.mydoc123.com/p-524249.html